148 research outputs found

    Validation tests of the CMS TIB/TID structures

    Get PDF
    Tracker Inner Barrel half-cylinders and Tracker Inner Disks of the CMS tracker have been integrated in three INFN sites. Integrated structures are submitted to an extensive set of tests whose main aim is to validate the functioning of the structures in CMS-like conditions. The tests have furthermore proven to be a great opportunity to study several aspects of the performance in detail. In this note the tests are described in some detail and an overview of the results is presented

    An underground Sagnac gyroscope with sub-prad/s rotation rate sensitivity: toward General Relativity tests on Earth

    Get PDF
    Measuring in a single location on Earth its angular rotation rate with respect to the celestial frame, with a sensitivity enabling access to the tiny Lense-Thirring effect is an extremely challenging task. GINGERINO is a large frame ring laser gyroscope, operating free running and unattended inside the underground laboratory of the Gran Sasso, Italy. The main geodetic signals, i.e., Annual and Chandler wobbles, daily polar motion and Length of the Day, are recovered from GINGERINO data using standard linear regression methods, demonstrating a sensitivity better than 1 prad/s, therefore close to the requirements for an Earth-based Lense-Thirring test.Comment: 7 pages, 5 figure

    Colorectal surgery in Italy during the Covid19 outbreak: a survey from the iCral study group

    Get PDF
    Background The COVID19 pandemic had a deep impact on healthcare facilities in Italy, with profound reorganization of surgical activities. The Italian ColoRectal Anastomotic Leakage (iCral) study group collecting 43 Italian surgical centers experienced in colorectal surgery from multiple regions performed a quick survey to make a snapshot of the current situation. Methods A 25-items questionnaire was sent to the 43 principal investigators of the iCral study group, with questions regard- ing qualitative and quantitative aspects of the surgical activity before and after the COVID19 outbreak. Results Two-thirds of the centers were involved in the treatment of COVID19 cases. Intensive care units (ICU) beds were partially or totally reallocated for the treatment of COVID19 cases in 72% of the hospitals. Elective colorectal surgery for malignancy was stopped or delayed in nearly 30% of the centers, with less than 20% of them still scheduling elective colo- rectal resections for frail and comorbid patients needing postoperative ICU care. A significant reduction of the number of colorectal resections during the time span from January to March 2020 was recorded, with significant delay in treatment in more than 50% of the centers. Discussion Our survey confirms that COVID19 outbreak is severely affecting the activity of colorectal surgery centers partici- pating to iCral study group. This could impact the activity of surgical centers for many months after the end of the emergency

    GINGER

    Full text link
    In this paper, we outline the scientific objectives, the experimental layout, and the collaborations envisaged for the GINGER (Gyroscopes IN GEneral Relativity) project. The GINGER project brings together different scientific disciplines aiming at building an array of Ring Laser Gyroscopes (RLGs), exploiting the Sagnac effect, to measure continuously, with sensitivity better than picorad/ s, large bandwidth (ca. 1 kHz), and high dynamic range, the absolute angular rotation rate of the Earth. In the paper, we address the feasibility of the apparatus with respect to the ambitious specifications above, as well as prove how such an apparatus, which will be able to detect strong Earthquakes, very weak geodetic signals, as well as general relativity effects like Lense-Thirring and De Sitter, will help scientific advancements in Theoretical Physics, Geophysics, and Geodesy, among other scientific fields.Comment: 21 pages, 9 figure

    Abdominal drainage after elective colorectal surgery: propensity score-matched retrospective analysis of an Italian cohort

    Get PDF
    background: In italy, surgeons continue to drain the abdominal cavity in more than 50 per cent of patients after colorectal resection. the aim of this study was to evaluate the impact of abdominal drain placement on early adverse events in patients undergoing elective colorectal surgery. methods: a database was retrospectively analysed through a 1:1 propensity score-matching model including 21 covariates. the primary endpoint was the postoperative duration of stay, and the secondary endpoints were surgical site infections, infectious morbidity rate defined as surgical site infections plus pulmonary infections plus urinary infections, anastomotic leakage, overall morbidity rate, major morbidity rate, reoperation and mortality rates. the results of multiple logistic regression analyses were presented as odds ratios (OR) and 95 per cent c.i. results: a total of 6157 patients were analysed to produce two well-balanced groups of 1802 patients: group (A), no abdominal drain(s) and group (B), abdominal drain(s). group a versus group B showed a significantly lower risk of postoperative duration of stay >6 days (OR 0.60; 95 per cent c.i. 0.51-0.70; P < 0.001). a mean postoperative duration of stay difference of 0.86 days was detected between groups. no difference was recorded between the two groups for all the other endpoints. conclusion: this study confirms that placement of abdominal drain(s) after elective colorectal surgery is associated with a non-clinically significant longer (0.86 days) postoperative duration of stay but has no impact on any other secondary outcomes, confirming that abdominal drains should not be used routinely in colorectal surgery

    Tracker Operation and Performance at the Magnet Test and Cosmic Challenge

    Get PDF
    During summer 2006 a fraction of the CMS silicon strip tracker was operated in a comprehensive slice test called the Magnet Test and Cosmic Challenge (MTCC). At the MTCC, cosmic rays detected in the muon chambers were used to trigger the readout of all CMS sub-detectors in the general data acquisition system and in the presence of the 4 T magnetic field produced by the CMS superconducting solenoid. This document describes the operation of the Tracker hardware and software prior, during and after data taking. The performance of the detector as resulting from the MTCC data analysis is also presented

    Bowel preparation for elective colorectal resection: multi-treatment machine learning analysis on 6241 cases from a prospective Italian cohort

    Get PDF
    background current evidence concerning bowel preparation before elective colorectal surgery is still controversial. this study aimed to compare the incidence of anastomotic leakage (AL), surgical site infections (SSIs), and overall morbidity (any adverse event, OM) after elective colorectal surgery using four different types of bowel preparation. methods a prospective database gathered among 78 Italian surgical centers in two prospective studies, including 6241 patients who underwent elective colorectal resection with anastomosis for malignant or benign disease, was re-analyzed through a multi-treatment machine-learning model considering no bowel preparation (NBP; No. = 3742; 60.0%) as the reference treatment arm, compared to oral antibiotics alone (oA; No. = 406; 6.5%), mechanical bowel preparation alone (MBP; No. = 1486; 23.8%), or in combination with oAB (MoABP; No. = 607; 9.7%). twenty covariates related to biometric data, surgical procedures, perioperative management, and hospital/center data potentially affecting outcomes were included and balanced into the model. the primary endpoints were AL, SSIs, and OM. all the results were reported as odds ratio (OR) with 95% confidence intervals (95% CI). results compared to NBP, MBP showed significantly higher AL risk (OR 1.82; 95% CI 1.23-2.71; p = .003) and OM risk (OR 1.38; 95% CI 1.10-1.72; p = .005), no significant differences for all the endpoints were recorded in the oA group, whereas MoABP showed a significantly reduced SSI risk (OR 0.45; 95% CI 0.25-0.79; p = .008). conclusions MoABP significantly reduced the SSI risk after elective colorectal surgery, therefore representing a valid alternative to NBP

    Virgo gravitational wave detector: Results and perspectives

    Get PDF
    The Virgo detector reached during the past science run a sensitivity very close to the design one. During the last year the detector has been improved by suspending the main interferometer mirrors with monolithic fibers, with the goal of reducing the thermal noise contribution and testing the new technology. At the same time the design of the next detector improvements are on-going and they will be implemented during the construction of Advanced Virgo
    • 

    corecore