976 research outputs found

    Laboratory implementation of edge illumination X-ray phase-contrast imaging with energy-resolved detectors

    Get PDF
    Edge illumination (EI) X-ray phase-contrast imaging (XPCI) has potential for applications in different fields of research, including materials science, non-destructive industrial testing, small-animal imaging, and medical imaging. One of its main advantages is the compatibility with laboratory equipment, in particular with conventional non-microfocal sources, which makes its exploitation in normal research laboratories possible. In this work, we demonstrate that the signal in laboratory implementations of EI can be correctly described with the use of the simplified geometrical optics. Besides enabling the derivation of simple expressions for the sensitivity and spatial resolution of a given EI setup, this model also highlights the EI’s achromaticity. With the aim of improving image quality, as well as to take advantage of the fact that all energies in the spectrum contribute to the image contrast, we carried out EI acquisitions using a photon-counting energy-resolved detector. The obtained results demonstrate that this approach has great potential for future laboratory implementations of EI. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only

    Comparing signal intensity and refraction sensitivity of double and single mask edge illumination lab-based x-ray phase contrast imaging set-ups

    Get PDF
    Double mask edge illumination (DM-EI) set-ups can detect differential phase and attenuation information from a sample. However, analytical separation of the two signals often requires acquiring two frames with inverted differential phase contrast signals. Typically, between these two acquisitions, the first mask is moved to create a different illumination condition. This can lead to potential errors which adversely affect the data collected. In this paper, we implement a single mask EI laboratory set-up that allows for a single shot retrieval of the differential phase and attenuation images, without the need for a high resolution detector or high magnification. As well as simplifying mask alignment, the advantages of the proposed set-up can be exploited in one of two ways: either the total acquisition time can be halved with respect to the DM-EI set-up or, for the same acquisition time, twice the statistics can be collected. In this latter configuration, the signal-to-noise ratio and contrast in the mixed intensity images, and the angular sensitivity of the two set-ups were compared. We also show that the angular sensitivity of the single mask set-up can be well approximated from its illumination curve, which has been modelled as a convolution between the source spatial distribution at the detector plane, the pre-sample mask and the detector point spread function (PSF). A polychromatic wave optics simulation was developed on these bases and benchmarked against experimental data. It can also be used to predict the angular sensitivity and contrast of any set-up as a function of detector PSF

    Xenotransplantation of microencapsulated pancreatic islets contained in a vascular prosthesis: preliminary results

    Get PDF
    Porcine and human pancreatic islets were microencapsulated in an alginate-polylysine biomembrane and put in a chamber of a new vascular prosthesis composed of an inner tubing of Dacron mesh and an outer tubing of expanded polytetrafluorethylene material. The vascular prosthesis was anastomized between the iliac artery and the contralateral vein of diabetic dogs. The recipients did not receive any immunosuppressive therapy. Function of porcine and human islets was monitored by measuring serum glucose levels and human C-peptide concentrations. After transplantation, serum glucose levels were maintained at values lower than 200 mg/dl, and C-peptide concentrations were between 0.8 and 3.2 ng/ml. Injected insulin requirements decreased by 50%-60%. Four to 8 weeks after transplantation, histologic examination showed well-preserved and functioning islets in the majority of intact microcapsules. Fibrin and inflammatory cells were not observed in the chamber. These data suggest long-term survival and function of microencapsulated pancreatic islets in the vascular prosthesis. © 1991 Springer-Verlag

    Time-dependent reduction of structural complexity of the buccal epithelial cell nuclei after treatment with silver nanoparticles

    Get PDF
    Recent studies have suggested that silver nanoparticles (AgNPs) may affect cell DNA structure in in vitro conditions. In this paper, we present the results indicating that AgNPs change nuclear complexity properties in isolated human epithelial buccal cells in a time-dependent manner. Epithelial buccal cells were plated in special tissue culture chamber / slides and were kept at 37°C in an RPMI 1640 cell culture medium supplemented with L-glutamine. The cells were treated with colloidal silver nanoparticles suspended in RPMI 1640 medium at the concentration 15 mg L−1. Digital micrographs of the cell nuclei in a sample of 30 cells were created at five different time steps: before the treatment (controls), immediately after the treatment, as well as 15 , 30 and 60 min after the treatment with AgNPs. For each nuclear structure, values of fractal dimension, lacunarity, circularity, as well as parameters of grey level co-occurrence matrix (GLCM) texture, were determined. The results indicate time-dependent reduction of structural complexity in the cell nuclei after the contact with AgNPs. These findings further suggest that AgNPs, at concentrations present in today's over-the-counter drug products, might have significant effects on the cell genetic material

    Detector requirements for single mask edge illumination x-ray phase contrast imaging applications

    Full text link
    Edge illumination (EI) is a non-interferometric X-ray phase contrast imaging (XPCI) method that has been successfully implemented with conventional polychromatic sources, thanks to its relaxed coherence requirements. Like other XPCI methods, EI enables the retrieval of absorption, refraction and ultra-small angle X-ray scattering (USAXS) signals. However, current retrieval algorithms require three input frames, which have so far been acquired under as many different illumination conditions, in separate exposures. These illumination conditions can be achieved by deliberately misaligning the set-up in different ways. Each one of these misaligned configurations can then be used to record frames containing a mixture of the absorption, refraction and scattering signals. However, this acquisition scheme involves lengthy exposure times, which can also introduce errors to the retrieved signals. Such errors have, so far, been mitigated by careful image acquisition and analysis. However, further reduction to image acquisition time and errors due to sample mask/sample movement can increase the advantages offered by the EI technique, and enable targeting more challenging applications. In this paper, we describe two simplified set-ups that exploit state-of-the-art detector technologies to achieve single-shot multi-modal imaging.Comment: 10 pages, 5 figures, Position Sensitive Detectors 11 conferenc

    Bioaccessibility Tests Accurately Estimate Bioavailability Of Lead To Quail

    Get PDF
    Hazards of soil-borne lead (Pb) to wild birds may be more accurately quantified if the bioavailability of that Pb is known. To better understand the bioavailability of Pb to birds, the authors measured blood Pb concentrations in Japanese quail (Coturnix japonica) fed diets containing Pb-contaminated soils. Relative bioavailabilities were expressed by comparison with blood Pb concentrations in quail fed a Pb acetate reference diet. Diets containing soil from 5 Pb-contaminated Superfund sites had relative bioavailabilities from 33% to 63%, with a mean of approximately 50%. Treatment of 2 of the soils with phosphorus (P) significantly reduced the bioavailability of Pb. Bioaccessibility of Pb in the test soils was then measured in 6 in vitro tests and regressed on bioavailability: the relative bioavailability leaching procedure at pH 1.5, the same test conducted at pH 2.5, the Ohio State University in vitro gastrointestinal method, the urban soil bioaccessible lead test, the modified physiologically based extraction test, and the waterfowl physiologically based extraction test. All regressions had positive slopes. Based on criteria of slope and coefficient of determination, the relative bioavailability leaching procedure at pH 2.5 and Ohio State University in vitro gastrointestinal tests performed very well. Speciation by X-ray absorption spectroscopy demonstrated that, on average, most of the Pb in the sampled soils was sorbed to minerals (30%), bound to organic matter (24%), or present as Pb sulfate (18%). Additional Pb was associated with P (chloropyromorphite, hydroxypyromorphite, and tertiary Pb phosphate) and with Pb carbonates, leadhillite (a lead sulfate carbonate hydroxide), and Pb sulfide. The formation of chloropyromorphite reduced the bioavailability of Pb, and the amendment of Pb-contaminated soils with P may be a thermodynamically favored means to sequester Pb
    corecore