6,264 research outputs found
The design and analysis of single flank transmission error tester for loaded gears
To strengthen the understanding of gear transmission error and to verify mathematical models which predict them, a test stand that will measure the transmission error of gear pairs under design loads has been investigated. While most transmission error testers have been used to test gear pairs under unloaded conditions, the goal of this report was to design and perform dynamic analysis of a unique tester with the capability of measuring the transmission error of gears under load. This test stand will have the capability to continuously load a gear pair at torques up to 16,000 in-lb at shaft speeds from 0 to 5 rpm. Error measurement will be accomplished with high resolution optical encoders and the accompanying signal processing unit from an existing unloaded transmission error tester. Input power to the test gear box will be supplied by a dc torque motor while the load will be applied with a similar torque motor. A dual input, dual output control system will regulate the speed and torque of the system. This control system's accuracy and dynamic response were analyzed and it was determined that proportional plus derivative speed control is needed in order to provide the precisely constant torque necessary for error-free measurement
The design and analysis of single flank transmission error testor for loaded gears
Due to geometrical imperfections in gears and finite tooth stiffnesses, the motion transmitted from an input gear shaft to an output gear shaft will not have conjugate action. In order to strengthen the understanding of transmission error and to verify mathematical models of gear transmission error, a test stand that will measure the transmission error of a gear pair at operating loads, but at reduced speeds would be desirable. This document describes the design and development of a loaded transmission error tester. For a gear box with a gear ratio of one, few tooth meshing combinations will occur during a single test. In order to observe the effects of different tooth mesh combinations and to increase the ability to load test gear pairs with higher gear ratios, the system was designed around a gear box with a gear ratio of two
Complex permittivity measurements of lunar samples at microwave and millimeter wavelengths
The relative dielectric constant and loss tangent of lunar sample 14163,164 (fine dust) were determined as a function of density at 9.375, 24, 35, and 60 GHz. In addition, such measurements have also been performed on lunar sample 14310,74 (solid rock) at 9.375 GHz. The loss tangent was found to be frequency independent at these test frequencies and had a value of 0.015 for the lunar dust sample
The MMI cash-futures spread on October 19, 1987
Includes bibliographical references (p. 29)
Amplified Sensitivity of Nitrogen-Vacancy Spins in Nanodiamonds using All-Optical Charge Readout
Nanodiamonds containing nitrogen-vacancy (NV) centers offer a versatile
platform for sensing applications spanning from nanomagnetism to in-vivo
monitoring of cellular processes. In many cases, however, weak optical signals
and poor contrast demand long acquisition times that prevent the measurement of
environmental dynamics. Here, we demonstrate the ability to perform fast,
high-contrast optical measurements of charge distributions in ensembles of NV
centers in nanodiamonds and use the technique to improve the spin readout
signal-to-noise ratio through spin-to-charge conversion. A study of 38
nanodiamonds, each hosting 10-15 NV centers with an average diameter of 40 nm,
uncovers complex, multiple-timescale dynamics due to radiative and
non-radiative ionization and recombination processes. Nonetheless, the
nanodiamonds universally exhibit charge-dependent photoluminescence contrasts
and the potential for enhanced spin readout using spin-to-charge conversion. We
use the technique to speed up a relaxometry measurement by a factor of
five.Comment: 13 pages, 14 figure
- …