1,473 research outputs found

    Sensitivity of the spherical gravitational wave detector MiniGRAIL operating at 5 K

    Get PDF
    We present the performances and the strain sensitivity of the first spherical gravitational wave detector equipped with a capacitive transducer and read out by a low noise two-stage SQUID amplifier and operated at a temperature of 5 K. We characterized the detector performance in terms of thermal and electrical noise in the system output sygnal. We measured a peak strain sensitivity of 1.5⋅10−20Hz−1/21.5\cdot 10^{-20} Hz^{-1/2} at 2942.9 Hz. A strain sensitivity of better than 5⋅10−20Hz−1/25\cdot 10{-20}Hz{-1/2} has been obtained over a bandwidth of 30 Hz. We expect an improvement of more than one order of magnitude when the detector will operate at 50 mK. Our results represent the first step towards the development of an ultracryogenic omnidirectional detector sensitive to gravitational radiation in the 3kHz range.Comment: 8 pages, 5 figures, submitted to Physical Review

    Increasing the bandwidth of resonant gravitational antennas: The case of Explorer

    Full text link
    Resonant gravitational wave detectors with an observation bandwidth of tens of hertz are a reality: the antenna Explorer, operated at CERN by the ROG collaboration, has been upgraded with a new read-out. In this new configuration, it exhibits an unprecedented useful bandwidth: in over 55 Hz about its frequency of operation of 919 Hz the spectral sensitivity is better than 10^{-20} /sqrt(Hz) . We describe the detector and its sensitivity and discuss the foreseable upgrades to even larger bandwidths.Comment: 4 pages- 4 figures Acceted for publication on Physical Review Letter

    Reception frequency bandwidth of a gravitational resonant detector with optical readout

    Full text link
    A gravitational resonant bar detector with a large scale Fabry-Perot cavity as an optical read out and a mechanical displacement transformer is considered. We calculate, in a fully analytical way, the final receiver bandwidth in which the potential sensitivity, limited only by the bar thermal noise, is maintained despite the additional thermal noise of the transformer and the additive noise of the optical readout. We discuss also an application to the OGRAN project, where the bar is instrumented with a 2m long FP cavity.Comment: 16 pages + 3 figures. Accepted for publicationi in Class. Quantum Gra

    Dark Matter searches using gravitational wave bar detectors: quark nuggets and newtorites

    Get PDF
    Many experiments have searched for supersymmetric WIMP dark matter, with null results. This may suggest to look for more exotic possibilities, for example compact ultra-dense quark nuggets, widely discussed in literature with several different names. Nuclearites are an example of candidate compact objects with atomic size cross section. After a short discussion on nuclearites, the result of a nuclearite search with the gravitational wave bar detectors Nautilus and Explorer is reported. The geometrical acceptance of the bar detectors is 19.5 m2\rm m^2 sr, that is smaller than that of other detectors used for similar searches. However, the detection mechanism is completely different and is more straightforward than in other detectors. The experimental limits we obtain are of interest because, for nuclearites of mass less than 10−510^{-5} g, we find a flux smaller than that one predicted considering nuclearites as dark matter candidates. Particles with gravitational only interactions (newtorites) are another example. In this case the sensitivity is quite poor and a short discussion is reported on possible improvements.Comment: published on Astroparticle Physics Sept 25th 2016 replaced fig 1

    MiniGRAIL progress report 2004

    Get PDF
    The MiniGRAIL detector was improved. The sphere was replaced by a slightly larger one, having a diameter of 68 cm (instead of 65 cm), reducing the resonant frequency by about 200 Hz to around 2.9 kHz. The last four masses of the attenuation system were machined to increase their resonant frequency and improve the attenuation around the resonant frequency of the sphere. In the new sphere, six holes were machined on the TIGA positions for easy mounting of the transducers. During the last cryogenic run, two capacitive transducers and a calibrator were mounted on the sphere. The first transducer was coupled to a double-stage SQUID amplifier having a commercial quantum design SQUID as a first stage and a DROS as a second stage. The second transducer was read by a single-stage quantum design SQUID. During the cryogenic run, the sphere was cooled down to 4 K. The two-stage SQUID had a flux noise of about 1.6 ÎŒ0 Hz−1/2. The detector was calibrated and the sensitivity curve of MiniGRAIL was determined

    Quark nuggets search using 2350 Kg gravitational waves aluminum bar detectors

    Get PDF
    The gravitational wave resonant detectors can be used as detectors of quark nuggets, like nuclearites (nuclear matter with a strange quark). This search has been carried out using data from two 2350 Kg, 2 K cooled, aluminum bar detectors: NAUTILUS, located in Frascati (Italy), and EXPLORER, that was located in CERN Geneva (CH). Both antennas are equipped with cosmic ray shower detectors: signals in the bar due to showers are continuously detected and used to characterize the antenna performances. The bar excitation mechanism is based on the so called thermo-acoustic effect, studied on dedicated experiments that use particle beams. This mechanism predicts that vibrations of bars are induced by the heat deposited in the bar from the particle. The geometrical acceptance of the bar detectors is 19.5 m2\rm m^2 sr, that is smaller than that of other detectors used for similar searches. However, the detection mechanism is completely different and is more straightforward than in other detectors. We will show the results of ten years of data from NAUTILUS (2003-2012) and 7 years from EXPLORER (2003-2009). The experimental limits we obtain are of interest because, for nuclearites of mass less than 10−410^{-4} grams, we find a flux smaller than that one predicted considering nuclearites as dark matter candidates.Comment: presented to the 33rd International Cosmic Ray Conference Rio de Janeiro 201

    Axion-like particle effects on the polarization of cosmic high-energy gamma sources

    Get PDF
    Various satellite-borne missions are being planned whose goal is to measure the polarization of a large number of gamma-ray bursts (GRBs). We show that the polarization pattern predicted by current models of GRB emission can be drastically modified by the existence of very light axion-like particles (ALPs), which are present in many extensions of the Standard Model of particle physics. Basically, the propagation of photons emitted by a GRB through cosmic magnetic fields with a domain-like structure induces photon-ALP mixing, which is expected to produce a strong modification of the original photon polarization. Because of the random orientation of the magnetic field in each domain, this effect strongly depends on the orientation of the photon line of sight. As a consequence, photon-ALP conversion considerably broadens the original polarization distribution. Searching for such a peculiar feature through future high-statistics polarimetric measurements is therefore a new opportunity to discover very light ALPs.Comment: Final version (21 pages, 8 eps figures). Matches the version published on JCAP. Added a Section on the effects of cosmic expansion on photon-ALP conversions. Figures modified to take into account this effect. References updated. Conclusions unchanged

    On the Sensitivity of a Hollow Sphere as a Multi-modal Resonant Gravitational Wave Detector

    Full text link
    We present a numerical analysis to simulate the response of a spherical resonant gravitational wave detector and to compute its sensitivity. Under the assump- tion of optimal filtering, we work out the sensitivity curve for a sphere first taking into account only a single transducer, and then using a coherent analysis of the whole set of transducers.Comment: 24 pages, 11 figures, published versio

    Raman-based Distributed Temperature Sensor Using Simplex Code And Gain Controlled Edfa

    Get PDF
    In this work we present a comparison between simplex coded and optical amplified simplex coded Raman based Distributed Temperature Sensing (DTS). An increase in performance is demonstrated using erbium doped fiber amplifier (EDFA) with proper gain control scheme that allows a DTS operates with simplex code. Using 63-bit simplex code and gain controlled EDFA we demonstrated the temperature resolution and dynamic range improvement in 16 degrees C @ 10 km and 4 dB, respectively.963

    Analysis of 3 years of data from the gravitational wave detectors EXPLORER and NAUTILUS

    Full text link
    We performed a search for short gravitational wave bursts using about 3 years of data of the resonant bar detectors Nautilus and Explorer. Two types of analysis were performed: a search for coincidences with a low background of accidentals (0.1 over the entire period), and the calculation of upper limits on the rate of gravitational wave bursts. Here we give a detailed account of the methodology and we report the results: a null search for coincident events and an upper limit that improves over all previous limits from resonant antennas, and is competitive, in the range h_rss ~1E-19, with limits from interferometric detectors. Some new methodological features are introduced that have proven successful in the upper limits evaluation.Comment: 12 pages, 12 figure
    • 

    corecore