28 research outputs found

    Ion mobility spectrometry coupled to laser-induced fluorescence for probing the electronic structure and conformation of gas-phase ions

    Get PDF
    We report on an improved design of a differential ion mobility analyzer (DMA) coupled to laser-induced fluorescence (LIF) for the simultaneous retrieval of two-dimensional information on the electric mobility and fluorescence spectroscopy of gas-phase ions. This enhanced design includes an ion funnel inter-face at the input orifice of the DMA and a nozzle beam stage at the output of the DMA. These improvements allow the detection of fluorescence not only from pure dyes and their clusters, as was demonstrated recently, but also from fluorophore-tagged biomolecules. Complex mixtures of fluorescent compounds can be separated by the DMA and studied by LIF. This unique combination of instruments also provides a powerful platform for probing fluorescent proteins in the gas phase. The green fluorescent protein (GFP) was tested on a new setup. In contrast to high vacuum, where no GFP fluorescence was detected, the presence of a LIF signal at the output of the DMA could explain some specific fluorescent properties of GFP in the gas phase. Given that both conformation and fluorescence are key properties of biological molecules in the gas phase, we expect that our enhanced design will answer the question whether gas-phase proteins retain their liquid-phase native structure or not

    Stable endocytic structures navigate the complex pellicle of apicomplexan parasites

    Get PDF
    Apicomplexan parasites have immense impacts on humanity, but their basic cellular processes are often poorly understood. Where endocytosis occurs in these cells, how conserved this process is with other eukaryotes, and what the functions of endocytosis are across this phylum are major unanswered questions. Using the apicomplexan model Toxoplasma, we identified the molecular composition and behavior of unusual, fixed endocytic structures. Here, stable complexes of endocytic proteins differ markedly from the dynamic assembly/disassembly of these machineries in other eukaryotes. We identify that these endocytic structures correspond to the ‘micropore’ that has been observed throughout the Apicomplexa. Moreover, conserved molecular adaptation of this structure is seen in apicomplexans including the kelch-domain protein K13 that is central to malarial drug-resistance. We determine that a dominant function of endocytosis in Toxoplasma is plasma membrane homeostasis, rather than parasite nutrition, and that these specialized endocytic structures originated early in infrakingdom Alveolata likely in response to the complex cell pellicle that defines this medically and ecologically important ancient eukaryotic lineage

    Aptamer-ligand recognition studied by native ion mobility-mass spectrometry

    No full text
    The range of applications for aptamers, small oligonucleotide-based receptors binding to their targets with high specificity and affinity, has been steadily expanding. Our understanding of the mechanisms governing aptamer-ligand recognition and binding is however lagging, stymieing the progress in the rational design of new aptamers and optimization of the known ones. Here we demonstrate the capabilities and limitations of native ion mobility-mass spectrometry for the analysis of their higher-order structure and non-covalent interactions. A set of related cocaine-binding aptamers, displaying a range of folding properties and ligand binding affinities, was used as a case study in both positive and negative electrospray ionization modes. Using carefully controlled experimental conditions, we probed their conformational behavior and interactions with the high-affinity ligand quinine as a surrogate for cocaine. The ratios of bound and unbound aptamers in the mass spectra were used to rank them according to their apparent quinine-binding affinity, qualitatively matching the published ranking order. The arrival time differences between the free aptamer and aptamer-quinine complexes were consistent with a small ligand-induced conformational change, and found to inversely correlate with the affinity of binding. This mass spectrometry-based approach provides a fast and convenient way to study the molecular basis of aptamer-ligand recognition

    A Prioritized and Validated Resource of Mitochondrial Proteins in Plasmodium Identifies Unique Biology

    Get PDF
    Plasmodium species have a single mitochondrion that is essential for their survival and has been successfully targeted by antimalarial drugs. Most mitochondrial proteins are imported into this organelle, and our picture of the Plasmodium mitochondrial proteome remains incomplete. Many data sources contain information about mitochondrial localization, including proteome and gene expression profiles, orthology to mitochondrial proteins from other species, coevolutionary relationships, and amino acid sequences, each with different coverage and reliability. To obtain a comprehensive, prioritized list of Plasmodium falciparum mitochondrial proteins, we rigorously analyzed and integrated eight data sets using Bayesian statistics into a predictive score per protein for mitochondrial localization. At a corrected false discovery rate of 25%, we identified 445 proteins with a sensitivity of 87% and a specificity of 97%. They include proteins that have not been identified as mitochondrial in other eukaryotes but have characterized homologs in bacteria that are involved in metabolism or translation. Mitochondrial localization of seven Plasmodium berghei orthologs was confirmed by epitope labeling and colocalization with a mitochondrial marker protein. One of these belongs to a newly identified apicomplexan mitochondrial protein family that in P. falciparum has four members. With the experimentally validated mitochondrial proteins and the complete ranked P. falciparum proteome, which we have named PlasmoMitoCarta, we present a resource to study unique proteins of Plasmodium mitochondria. IMPORTANCE The unique biology and medical relevance of the mitochondrion of the malaria parasite Plasmodium falciparum have made it the subject of many studies. However, we actually do not have a comprehensive assessment of which proteins reside in this organelle. Many omics data are available that are predictive of mitochondrial localization, such as proteomics data and expression data. Individual data sets are, however, rarely complete and can provide conflicting evidence. We integrated a wide variety of available omics data in a manner that exploits the relative strengths of the data sets. Our analysis gave a predictive score for the mitochondrial localization to each nuclear encoded P. falciparum protein and identified 445 likely mitochondrial proteins. We experimentally validated the mitochondrial localization of seven of the new mitochondrial proteins, confirming the quality of the complete list. These include proteins that have not been observed mitochondria before, adding unique mitochondrial functions to P. falciparum

    A New, Modular Mass Calibrant for High-Mass MALDI-MS

    Full text link
    The application of matrix-assisted laser desorption/ionization mass spectrometry (MALDIMS) for the analysis of high-mass proteins requires suitable calibration standards at high m/z ratios. Several possible candidates were investigated, and concatenated polyproteins based on recombinantly expressed maltodextrin-binding protein (MBP) are shown here to be well suited for this purpose. Introduction of two specific recognition sites into the primary sequence of the polyprotein allows for the selective cleavage of MBP3 into MBP and MBP2. Moreover, these MBP2 and MBP3 oligomers can be dimerized specifically, such that generation of MPB4 and MBP6 is possible as well. With the set of calibrants presented here, the m/z range of 40–400 kDa is covered. Since all calibrants consist of the same species and differ only in mass, the ionization efficiency is expected to be similar. However, equimolar mixtures of these proteins did not yield equal signal intensities on a detector specifically designed for detecting high-mass molecules
    corecore