115 research outputs found

    Efficacy of a hybrid assistive limb in post-stroke hemiplegic patients: a preliminary report

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Robotic devices are expected to be widely used in various applications including support for the independent mobility of the elderly with muscle weakness and people with impaired motor function as well as support for nursing care that involves heavy laborious work. We evaluated the effects of a hybrid assistive limb robot suit on the gait of stroke patients undergoing rehabilitation.</p> <p>Methods</p> <p>The study group comprised 16 stroke patients with severe hemiplegia. All patients underwent gait training. Four patients required assistance, and 12 needed supervision while walking. The stride length, walking speed and physiological cost index on wearing the hybrid assistive limb suit and a knee-ankle-foot orthosis were compared.</p> <p>Results</p> <p>The hybrid assistive limb suit increased the stride length and walking speed in 4 of 16 patients. The patients whose walking speed decreased on wearing the hybrid assistive limb suit either had not received sufficient gait training or had an established gait pattern with a knee-ankle-foot orthosis using a quad cane. The physiological cost index increased after wearing the hybrid assistive limb suit in 12 patients, but removal of the suit led to a decrease in the physiological cost index values to equivalent levels prior to the use of the suit.</p> <p>Conclusions</p> <p>Although the hybrid assistive limb suit is not useful for all hemiplegic patients, it may increase the walking speed and affect the walking ability. Further investigation would clarify its indication for the possibility of gait training.</p

    Feasibility Study of a Wearable Exoskeleton for Children: Is the Gait Altered by Adding Masses on Lower Limbs?

    Get PDF
    We are designing a pediatric exoskeletal ankle robot (pediatric Anklebot) to promote gait habilitation in children with Cerebral Palsy (CP). Few studies have evaluated how much or whether the unilateral loading of a wearable exoskeleton may have the unwanted effect of altering significantly the gait. The purpose of this study was to evaluate whether adding masses up to 2.5 kg, the estimated overall added mass of the mentioned device, at the knee level alters the gait kinematics. Ten healthy children and eight children with CP, with light or mild gait impairment, walked wearing a knee brace with several masses. Gait parameters and lower-limb joint kinematics were analyzed with an optoelectronic system under six conditions: without brace (natural gait) and with masses placed at the knee level (0.5, 1.0, 1.5, 2.0, 2.5 kg). T-tests and repeated measures ANOVA tests were conducted in order to find noteworthy differences among the trial conditions and between loaded and unloaded legs. No statistically significant differences in gait parameters for both healthy children and children with CP were observed in the five “with added mass” conditions. We found significant differences among “natural gait” and “with added masses” conditions in knee flexion and hip extension angles for healthy children and in knee flexion angle for children with CP. This result can be interpreted as an effect of the mechanical constraint induced by the knee brace rather than the effect associated with load increase. The study demonstrates that the mechanical constraint induced by the brace has a measurable effect on the gait of healthy children and children with CP and that the added mass up to 2.5 kg does not alter the lower limb kinematics. This suggests that wearable devices weighing 25 N or less will not noticeably modify the gait patterns of the population examined here.Cerebral Palsy International Research FoundationStavros S. Niarchos Foundatio

    Patient-cooperative control increases active participation of individuals with SCI during robot-aided gait training

    Get PDF
    ABSTRACT: BACKGROUND: Manual body weight supported treadmill training and robot-aided treadmill training are frequently used techniques for the gait rehabilitation of individuals after stroke and spinal cord injury. Current evidence suggests that robot-aided gait training may be improved by making robotic behavior more patient-cooperative. In this study, we have investigated the immediate effects of patient-cooperative versus non-cooperative robot-aided gait training on individuals with incomplete spinal cord injury (iSCI). METHODS: Eleven patients with iSCI participated in a single training session with the gait rehabilitation robot Lokomat. The patients were exposed to four different training modes in random order: During both non-cooperative position control and compliant impedance control, fixed timing of movements was provided. During two variants of the patient-cooperative path control approach, free timing of movements was enabled and the robot provided only spatial guidance. The two variants of the path control approach differed in the amount of additional support, which was either individually adjusted or exaggerated. Joint angles and torques of the robot as well as muscle activity and heart rate of the patients were recorded. Kinematic variability, interaction torques, heart rate and muscle activity were compared between the different conditions. RESULTS: Patients showed more spatial and temporal kinematic variability, reduced interaction torques, a higher increase of heart rate and more muscle activity in the patient-cooperative path control mode with individually adjusted support than in the non-cooperative position control mode. In the compliant impedance control mode, spatial kinematic variability was increased and interaction torques were reduced, but temporal kinematic variability, heart rate and muscle activity were not significantly higher than in the position control mode. CONCLUSIONS: Patient-cooperative robot-aided gait training with free timing of movements made individuals with iSCI participate more actively and with larger kinematic variability than non-cooperative, position-controlled robot-aided gait training

    Directed Evolution of a Selective and Sensitive Serotonin Sensor via Machine Learning

    Get PDF
    Serotonin plays a central role in cognition and is the target of most pharmaceuticals for psychiatric disorders. Existing drugs have limited efficacy; creation of improved versions will require better understanding of serotonergic circuitry, which has been hampered by our inability to monitor serotonin release and transport with high spatial and temporal resolution. We developed and applied a binding-pocket redesign strategy, guided by machine learning, to create a high-performance, soluble, fluorescent serotonin sensor (iSeroSnFR), enabling optical detection of millisecond-scale serotonin transients. We demonstrate that iSeroSnFR can be used to detect serotonin release in freely behaving mice during fear conditioning, social interaction, and sleep/wake transitions. We also developed a robust assay of serotonin transporter function and modulation by drugs. We expect that both machine-learning-guided binding-pocket redesign and iSeroSnFR will have broad utility for the development of other sensors and in vitro and in vivo serotonin detection, respectively

    Short-term locomotor adaptation to a robotic ankle exoskeleton does not alter soleus Hoffmann reflex amplitude

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To improve design of robotic lower limb exoskeletons for gait rehabilitation, it is critical to identify neural mechanisms that govern locomotor adaptation to robotic assistance. Previously, we demonstrated soleus muscle recruitment decreased by ~35% when walking with a pneumatically-powered ankle exoskeleton providing plantar flexor torque under soleus proportional myoelectric control. Since a substantial portion of soleus activation during walking results from the stretch reflex, increased reflex inhibition is one potential mechanism for reducing soleus recruitment when walking with exoskeleton assistance. This is clinically relevant because many neurologically impaired populations have hyperactive stretch reflexes and training to reduce the reflexes could lead to substantial improvements in their motor ability. The purpose of this study was to quantify soleus Hoffmann (H-) reflex responses during powered versus unpowered walking.</p> <p>Methods</p> <p>We tested soleus H-reflex responses in neurologically intact subjects (n=8) that had trained walking with the soleus controlled robotic ankle exoskeleton. Soleus H-reflex was tested at the mid and late stance while subjects walked with the exoskeleton on the treadmill at 1.25 m/s, first without power (first unpowered), then with power (powered), and finally without power again (second unpowered). We also collected joint kinematics and electromyography.</p> <p>Results</p> <p>When the robotic plantar flexor torque was provided, subjects walked with lower soleus electromyographic (EMG) activation (27-48%) and had concomitant reductions in H-reflex amplitude (12-24%) compared to the first unpowered condition. The H-reflex amplitude in proportion to the background soleus EMG during powered walking was not significantly different from the two unpowered conditions.</p> <p>Conclusion</p> <p>These findings suggest that the nervous system does not inhibit the soleus H-reflex in response to short-term adaption to exoskeleton assistance. Future studies should determine if the findings also apply to long-term adaption to the exoskeleton.</p

    Plant-Mediated Synthesis of Silver Nanoparticles: Their Characteristic Properties and Therapeutic Applications

    Get PDF

    Beta-cyclodextrin complexing to reduce antibiotic residue in milk

    Get PDF
    Various percentages (1.2% to 13%) of β- cyclodextrin (β–CD) were added to water or pasteurized whole milk to study β-CD crystallization patterns. Influential factors such as crystallization time (4 to 12 h), crystallization temperature (45º vs. 72ºF), and centrifugation speed (25 to 3000 × g) were investigated. Optimized crystallization conditions were verified in antibiotic-tainted raw milk samples via the enzyme-linked receptor-binding assay and by solids partitioning. In water, β-CD precipitate increased significantly as β-CD concentration and crystallization time increased, but was independent of the centrifugation speed. In pasteurized whole milk, precipitate increased as β-CD concentration, crystallization time, and centrifugation speed increased. The best β-CD precipitation conditions in milk were designated as: 9.1% β-CD concentration (w/w), 4 hour crystallization time, 45ºF, and centrifugation at 25 × g for 10 minutes. Eleven cows were treated with cephapirin sodium or cephapirin benzathine. Milk was obtained 12 h later and treated with β-CD. As β- CD concentrations increased, precipitates increased, and the corresponding supernatants showed reduced concentrations of antibiotics when tested by enzyme-linked receptorbinding assay. Results indicated that β-CD may have the potential to reduce the residues of cephapirin sodium or cephapirin benzathine in antibiotic-tainted raw milk
    corecore