35 research outputs found
Synchrony of hand-foot coupled movements: is it attained by mutual feedback entrainment or by independent linkage of each limb to a common rhythm generator?
BACKGROUND: Synchrony of coupled oscillations of ipsilateral hand and foot may be achieved by controlling the interlimb phase difference through a crossed kinaesthetic feedback between the two limbs, or by an independent linkage of each limb cycle to a common clock signal. These alternative models may be experimentally challenged by comparing the behaviour of the two limbs when they oscillate following an external time giver, either alone or coupled together. RESULTS: Ten subjects oscillated their right hand and foot both alone and coupled (iso- or antidirectionally), paced by a metronome. Wrist and ankle angular position and Electromyograms (EMG) from the respective flexor and extensor muscles were recorded. Three phase delays were measured: i) the clk-mov delay, between the clock (metronome beat) and the oscillation peak; ii) the neur (neural) delay, between the clock and the motoneurone excitatory input, as inferred from the EMG onset; and iii) the mech (mechanical) delay between the EMG onset and the corresponding point of the limb oscillation. During uncoupled oscillations (0.4 Hz to 3.0 Hz), the mech delay increased from -7° to -111° (hand) and from -4° to -83° (foot). In contrast, the clk-mov delay remained constant and close to zero in either limb since a progressive advance of the motoneurone activation on the pacing beat (neur advance) compensated for the increasing mech delay. Adding an inertial load to either extremity induced a frequency dependent increase of the limb mechanical delay that could not be completely compensated by the increase of the neural phase advance, resulting in a frequency dependent increment of clk-mov delay of the hampered limb. When limb oscillations were iso- or antidirectionally coupled, either in the loaded or unloaded condition, the three delays did not significantly change with respect to values measured when limbs were moved separately. CONCLUSION: The absence of any significant effect of limb coupling on the measured delays suggests that during hand-foot oscillations, both iso- and antidirectionally coupled, each limb is synchronised to the common rhythm generator by a "private" position control, with no need for a crossed feedback interaction between limbs
Chromosome evolution in Cophomantini (Amphibia, Anura, Hylinae)
The hylid tribe Cophomantini is a diverse clade of Neotropical treefrogs composed of the genera Aplastodiscus, Boana, Bokermannohyla, Hyloscirtus, and Myersiohyla. The phylogenetic relationships of Cophomantini have been comprehensively reviewed in the literature, providing a suitable framework for the study of chromosome evolution. Employing different banding techniques, we studied the chromosomes of 25 species of Boana and 3 of Hyloscirtus; thus providing, for the first time, data for Hyloscirtus and for 15 species of Boana. Most species showed karyotypes with 2n = 2x = 24 chromosomes; some species of the B. albopunctata group have 2n = 2x = 22, and H. alytolylax has 2n = 2x = 20. Karyotypes are all bi-armed in most species presented, with the exception of H. larinopygion (FN = 46) and H. alytolylax (FN = 38), with karyotypes that have a single pair of small telocentric chromosomes. In most species of Boana, NORs are observed in a single pair of chromosomes, mostly in the small chromosomes, although in some species of the B. albopunctata, B. pulchella, and B. semilineata groups, this marker occurs on the larger pairs 8, 1, and 7, respectively. In Hyloscirtus, NOR position differs in the three studied species: H. alytolylax (4p), H. palmeri (4q), and H. larinopygion (1p). Heterochromatin is a variable marker that could provide valuable evidence, but it would be necesserary to understand the molecular composition of the C-bands that are observed in different species in order to test its putative homology. In H. alytolylax, a centromeric DAPI+ band was observed on one homologue of chromosome pair 2. The band was present in males but absent in females, providing evidence for an XX/XY sex determining system in this species. We review and discuss the importance of the different chromosome markers (NOR position, C-bands, and DAPI/CMA3 patterns) for their impact on the taxonomy and karyotype evolution in Cophomantini
Somatosensory System Deficits in Schizophrenia Revealed by MEG during a Median-Nerve Oddball Task
Although impairments related to somatosensory perception are common in schizophrenia, they have rarely been examined in functional imaging studies. In the present study, magnetoencephalography (MEG) was used to identify neural networks that support attention to somatosensory stimuli in healthy adults and abnormalities in these networks in patient with schizophrenia. A median-nerve oddball task was used to probe attention to somatosensory stimuli, and an advanced, high-resolution MEG source-imaging method was applied to assess activity throughout the brain. In nineteen healthy subjects, attention-related activation was seen in a sensorimotor network involving primary somatosensory (S1), secondary somatosensory (S2), primary motor (M1), pre-motor (PMA), and paracentral lobule (PCL) areas. A frontal–parietal–temporal “attention network”, containing dorsal- and ventral–lateral prefrontal cortex (DLPFC and VLPFC), orbitofrontal cortex (OFC), anterior cingulate cortex (ACC), superior parietal lobule (SPL), inferior parietal lobule (IPL)/supramarginal gyrus (SMG), and temporal lobe areas, was also activated. Seventeen individuals with schizophrenia showed early attention-related hyperactivations in S1 and M1 but hypo-activation in S1, S2, M1, and PMA at later latency in the sensorimotor network. Within this attention network, hypoactivation was found in SPL, DLPFC, orbitofrontal cortex, and the dorsal aspect of ACC. Hyperactivation was seen in SMG/IPL, frontal pole, and the ventral aspect of ACC in patients. These findings link attention-related somatosensory deficits to dysfunction in both sensorimotor and frontal–parietal–temporal networks in schizophrenia
Anterior composite restorations in clinical practice: findings from a survey with general dental practitioners
OBJECTIVES: The aim of this study was to assess technical preferences of general dental practitioners when restoring anterior composite restorations. How the level of clinical experience or post-graduate training infuenced their options was also tested. MATERIAL AND METHODS: A cross-sectional study was performed using a questionnaire with general dental practitioners (GDPs) (n=276) in Southern Brazil. Information regarding post graduation training (specialization, master's or PhD degree) and linical experience (years since completing graduation) were gathered. The options regarding anterior composite restorations (type of composite, adhesive system, light curing unit, polishing procedures and rubber dam use) were collected. Data were submitted to descriptive analysis and associations were tested. RESULTS: Response rate was 68% (187). GDPs selected microhybrid composite (52%) and 2-step total etch adhesive system (77%). LED was the preferred method of activation for 72.8%. Immediate polishing was preferred by 75%, using a combination of techniques. Most of the respondents (74.3%) did not use rubber dam. More experienced clinicians used more halogen lights (p<0.022), performed more light monitoring (p<0.001) and were resistant to use rubber dam (p<0.012). Dentists with post-graduation training used 3-etch-and-rinse system more frequently (p<0.04), usually monitored light intensity (p<0.014) and placed rubber dam more frequently (p<0.044). CONCLUSIONS: Hybrid composite, simplifed adhesives, LED units and immediate polishing were preferred by Southern Brazilian dentists for anterior composite restorations. Few dentists used rubber dam to perform composite restorations in anterior teeth. Clinical experience and post-graduation training infuenced the dentists' choices