129 research outputs found

    Planning and designing an integrated management of coastal hypoxia in the Emila Romagna region water (Northern Adriatic Sea)

    Get PDF
    Abstract The design of an integrated monitoring network useful for the early-warning, the management and mitigation of both the environmental and socio-economic costs of hypoxia/anoxia events in the Northern Adriatic coastal zone, south of the mouth of the Po river, is described in the contribute. It has been developed within the EMMA research project (Environmental Management through Monitoring and Modelling of Anoxia; LIFE04ENV/IT/0479) (2004-2007). Over the past few decades, hypoxia events have recurrently affected the coastal zone of Emilia Romagna Region (Italy). Data collected by the C.Z. lying in the Province of Rimini, because of its economic importance, are presented. The area is subjected to intense anthropogenic pressure due to its high population (416 000 equivalent inhabitants) with tourist seasonal peaks of up to 973 110 equivalent inhabitants (in summer time), to industrial and agricultural activity, to maritime traffic and nutrient river discharges (about 600 tons y-1 of nitrogen and 300 tons y-1 of phosphorus, in 2002). Hypoxia and anoxia have a negative effect on the quality of bathing waters as well as on fishing and mussel farming, which are important activities for the economy of the area. The planning of the monitoring network has been carried out by analyzing the scientific knowledge on hypoxia in the local area; its integration with other existing monitoring activities, available facilities and data resources was considered in order to optimize cost effectiveness of the network

    Femtosecond x-ray diffraction from an aerosolized beam of protein nanocrystals

    Get PDF
    We demonstrate near-atomic-resolution Bragg diffraction from aerosolized single granulovirus crystals using an x-ray free-electron laser. The form of the aerosol injector is nearly identical to conventional liquid-microjet nozzles, but the x-ray-scattering background is reduced by several orders of magnitude by the use of helium carrier gas rather than liquid. This approach provides a route to study the weak diffuse or lattice-transform signal arising from small crystals. The high speed of the particles is particularly well suited to upcoming MHz-repetition-rate x-ray free-electron lasers

    Circulating microRNAs Reveal Time Course of Organ Injury in a Porcine Model of Acetaminophen-Induced Acute Liver Failure

    Get PDF
    Acute liver failure is a rare but catastrophic condition which can progress rapidly to multi-organ failure. Studies investigating the onset of individual organ injury such as the liver, kidneys and brain during the evolution of acute liver failure, are lacking. MicroRNAs are short, non-coding strands of RNA that are released into the circulation following tissue injury. In this study, we have characterised the release of both global microRNA and specific microRNA species into the plasma using a porcine model of acetaminophen-induced acute liver failure. Pigs were induced to acute liver failure with oral acetaminophen over 19h±2h and death occurred 13h±3h thereafter. Global microRNA concentrations increased 4h prior to acute liver failure in plasma (P<0.0001) but not in isolated exosomes, and were associated with increasing plasma levels of the damage-associated molecular pattern molecule, genomic DNA (P<0.0001). MiR122 increased around the time of onset of acute liver failure (P<0.0001) and was associated with increasing international normalised ratio (P<0.0001). MiR192 increased 8h after acute liver failure (P<0.0001) and was associated with increasing creatinine (P<0.0001). The increase in miR124-1 occurred concurrent with the pre-terminal increase in intracranial pressure (P<0.0001) and was associated with decreasing cerebral perfusion pressure (P<0.002)

    NQO2 is a reactive oxygen species generating off-target for acetaminophen

    Get PDF
    [Image: see text] The analgesic and antipyretic compound acetaminophen (paracetamol) is one of the most used drugs worldwide. Acetaminophen overdose is also the most common cause for acute liver toxicity. Here we show that acetaminophen and many structurally related compounds bind quinone reductase 2 (NQO2) in vitro and in live cells, establishing NQO2 as a novel off-target. NQO2 modulates the levels of acetaminophen derived reactive oxygen species, more specifically superoxide anions, in cultured cells. In humans, NQO2 is highly expressed in liver and kidney, the main sites of acetaminophen toxicity. We suggest that NQO2 mediated superoxide production may function as a novel mechanism augmenting acetaminophen toxicity

    New aerodynamic lens injector for single particle diffractive imaging

    Get PDF
    An aerodynamic lens injector was developed specifically for the needs of single-particle diffractive imaging experiments at free-electron lasers. Its design allows for quick changes of injector geometries and focusing properties in order to optimize injection for specific individual samples. Here, we present results of its first use at the FLASH free-electron-laser facility. Recorded diffraction patterns of polystyrene spheres are modeled using Mie scattering, which allowed for the characterization of the particle beam under diffractive-imaging conditions and yield good agreement with particle-trajectory simulations

    Time-resolved XUV Opacity Measurements of Warm-Dense Aluminium

    Full text link
    The free-free opacity in plasmas is fundamental to our understanding of energy transport in stellar interiors and for inertial confinement fusion research. However, theoretical predictions in the challenging dense plasma regime are conflicting and there is a dearth of accurate experimental data to allow for direct model validation. Here we present time-resolved transmission measurements in solid-density Al heated by an XUV free-electron laser. We use a novel functional optimization approach to extract the temperature-dependent absorption coefficient directly from an oversampled pool of single-shot measurements, and find a pronounced enhancement of the opacity as the plasma is heated to temperatures of order the Fermi energy. Plasma heating and opacity-enhancement is observed on ultrafast time scales, within the duration of the femtosecond XUV pulse. We attribute further rises in the opacity on ps timescales to melt and the formation of warm-dense matter

    EUV testing of multilayer mirrors: critical issues

    Get PDF
    Recently, while performing extensive EUV irradiation endurance testing on Ru-capped multilayer mirrors in the presence of elevated partial pressures of water and hydrocarbons, NIST has observed that the amount of EUV-induced damage actually decreases with increasing levels of water vapor above {approx} 5 x 10{sup -7} Torr. It is thought that the admitted water vapor may interact with otherwise stable, condensed carbonaceous species in an UHV vacuum system to increase the background levels of simple gaseous carbon-containing molecules. Some support for this hypothesis was demonstrated by observing the mitigating effect of very small levels of simple hydrocarbons with the intentional introduction of methyl alcohol in addition to the water vapor. It was found that the damage rate decreased by at least an order of magnitude when the partial pressure of methyl alcohol was just one percent of the water partial pressure. These observations indicate that the hydrocarbon components of the vacuum environment under actual testing conditions must be characterized and controlled to 10{sup -11} Torr or better in order to quantify the damage caused by high levels of water vapor. The possible effects of exposure beam size and out-of-band radiation on mirror lifetime testing will also be discussed

    Electronic damage in S atoms in a native protein crystal induced by an intense X-ray free-electron laser pulse

    Get PDF
    Current hard X-ray free-electron laser (XFEL) sources can deliver doses to biological macromolecules well exceeding 1 GGy, in timescales of a few tens of femtoseconds. During the pulse, photoionization can reach the point of saturation in which certain atomic species in the sample lose most of their electrons. This electronic radiation damage causes the atomic scattering factors to change, affecting, in particular, the heavy atoms, due to their higher photoabsorption cross sections. Here, it is shown that experimental serial femtosecond crystallography data collected with an extremely bright XFEL source exhibit a reduction of the effective scattering power of the sulfur atoms in a native protein. Quantitative methods are developed to retrieve information on the effective ionization of the damaged atomic species from experimental data, and the implications of utilizing new phasing methods which can take advantage of this localized radiation damage are discussed

    On the use of multilayer Laue lenses with X-ray Free Electron Lasers

    Get PDF
    Multilayer Laue lenses were used for the first time to focus x-rays from an X-ray Free Electron Laser (XFEL). In an experiment, which was performed at the European XFEL, we demonstrated focusing to a spot size of a few tens of nanometers. A series of runs in which the number of pulses per train was increased from 1 to 2, 3, 4, 5, 6, 7, 10, 20 and 30 pulses per train, all with a pulse separation of 3.55 us, was done using the same set of lenses. The increase in the number of pulses per train was accompanied with an increase of x-ray intensity (transmission) from 9% to 92% at 5 pulses per train, and then the transmission was reduced to 23.5 % when the pulses were increased further. The final working condition was 30 pulses per train and 23.5% transmission. Only at this condition we saw that the diffraction efficiency of the MLLs changed over the course of a pulse train, and this variation was reproducible from train to train. We present the procedure to align and characterize these lenses and discuss challenges working with the pulse trains from this unique x-ray source
    • …
    corecore