2,360 research outputs found

    Numerical simulation of wave resonance in the narrow gap between two non-identical boxes

    Get PDF
    Wave resonance in the narrow gap between two side-by-side non-identical boxes is investigated by employing a two-dimensional numerical wave flume based on the OpenFOAM R package. The focus of this study is to examine the influence of the energy transformation and the energy dissipation on the hydrodynamic behavior of wave response around resonant conditions. Numerical simulations show that the unrealistic wave resonant responses in the narrow gap by the linear potential flow model are due to not only the energy dissipation induced by the fluid rotational motion, but also the energy transformation associated with the free surface. With the increase of incident wave amplitude, relatively more energy is reflected, leading to the decrease of wave resonant response and energy dissipation in the narrow gap at the resonant frequency. When slightly away from the resonant frequency, the energy dissipation becomes the dominant factor for the decrease of wave response in the narrow gap with increasing the incident wave amplitude. As for the influence of gap configuration, on one hand, energy dissipation has the dominant effect for the typical case of small upstream and large downstream box drafts. On the other hand, the reflected energy is more important for the typical large upstream and small downstream box drafts. More resonant fluid exists in the gap with the increase of gap breadth, leading to the decrease of reflection coefficient and the increase of transmission coefficient

    Numerical investigation of wave forces on two side-by-side non-identical boxes in close proximity under wave actions

    Get PDF
    Wave forces on two side-by-side non-identical boxes in close proximity under wave actions are investigated by employing a numerical wave flume based on the OpenFOAM® package. The similarity and discrepancy of hydrodynamic behavior between the wave response in the narrow gap and the wave forces on the boxes are the focus of the present study. Around resonant frequencies, the large-amplitude piston-type free surface oscillation in the narrow gap can lead to the peak values in the horizontal and vertical wave forces on the downstream box, and the horizontal wave forces on the upstream box. However, only a rapid decrease with the incident wave frequencies can be observed for the vertical wave forces on the upstream box. The resonant frequencies of the wave forces on two boxes are also different with those of wave response in the narrow gap. With the increase of incident wave amplitude, the resonant frequencies and normalized amplitudes of wave forces on downstream box tend to be smaller, which is similar with that of wave response in the narrow gap. However, the normalized wave forces on the upstream box around resonant frequencies do not always decrease with the increase of incident wave amplitude. On the whole, the hydrodynamic behavior of wave forces has some similar characteristics with that of wave response in the narrow gap. However, evident discrepancy between them can also be observed because the other factors, such as the wave response upstream and downstream the two-box systems, also has the non-negligible contribution to wave forces

    Combining phage display with SMRTbell next-generation sequencing for the rapid discovery of functional scFv fragments

    Get PDF
    Phage display technology in combination with next-generation sequencing (NGS) currently is a state-of-the-art method for the enrichment and isolation of monoclonal antibodies from diverse libraries. However, the current NGS methods employed for sequencing phage display libraries are limited by the short contiguous read lengths associated with second-generation sequencing platforms. Consequently, the identification of antibody sequences has conventionally been restricted to individual antibody domains or to the analysis of single domain binding moieties such as camelid VHH or cartilaginous fish IgNAR antibodies. In this study, we report the application of third-generation sequencing to address this limitation. We used single molecule real time (SMRT) sequencing coupled with hairpin adaptor loop ligation to facilitate the accurate interrogation of full-length single-chain Fv (scFv) libraries. Our method facilitated the rapid isolation and testing of scFv antibodies enriched from phage display libraries within days following panning. Two libraries against CD160 and CD123 were panned and monitored by NGS. Analysis of NGS antibody data sets led to the isolation of several functional scFv antibodies that were not identified by conventional panning and screening strategies. Our approach, which combines phage display selection of immune libraries with the full-length interrogation of scFv fragments, is an easy method to discover functional antibodies, with a range of affinities and biophysical characteristics

    Development and evaluation of a new fully automatic motion detection and correction technique in cardiac SPECT imaging

    Get PDF
    In cardiac SPECT perfusion imaging, motion correction of the data is critical to the minimization of motion introduced artifacts in the reconstructed images. Software-based (data-driven) motion correction techniques are the most convenient and economical approaches to fulfill this purpose. However, the accuracy is significantly affected by how the data complexities, such as activity overlap, non-uniform tissue attenuation, and noise are handled. We developed STASYS, a new, fully automatic technique, for motion detection and correction in cardiac SPECT. We evaluated the performance of STASYS by comparing its effectiveness of motion correcting patient studies with the current industry standard software (Cedars-Sinai MoCo) through blind readings by two readers independently. For 204 patient studies from multiple clinical sites, the first reader identified (1) 69 studies with medium to large axial motion, of which STASYS perfectly or significantly corrected 86.9% and MoCo 72.5%; and (2) 20 studies with medium to large lateral motion, of which STASYS perfectly or significantly corrected 80.0% and MoCo 60.0%. The second reader identified (1) 84 studies with medium to large axial motion, of which STASYS perfectly or significantly corrected 82.2% and MoCo 76.2%; and (2) 34 studies with medium to large lateral motion, of which STASYS perfectly or significantly corrected 58.9% and MoCo 50.0%. We developed a fully automatic software-based motion correction technique, STASYS, for cardiac SPECT. Clinical studies showed that STASYS was effective and corrected a larger percent of cardiac SPECT studies than the current industrial standard software

    Efficacy of insect larval meal to replace fish meal in juvenile barramundi, Lates calcarifer reared in freshwater

    Get PDF
    The present experiment was conducted to evaluate the efficacy of dietary protein from black soldier fly, Hermetia illucens, larval meal (BSFL) to replace fish meal (FM) protein in juvenile barramundi, Lates calcarifer. Larvae of black soldier fly were fed with the underutilised crop, sesbania, Sesbania grandiflora. Five isonitrogenous (44% crude protein) and isocaloric (16.0 kJ available energy/g) experimental diets were formulated to replace FM using processed BSFL meal at 0 (control), 25% (BSFL25), 50% (BSFL50), 75% (BSFL75) and 100% (BSFL100). Data for proximate and amino acid analysis suggested BSFL meal as an inferior protein ingredient than FM, but parallel to soybean meal. At the end of 8 weeks of fish feeding trial, there were no significant differences in the average weight gain (WG) and specific growth rate among the group of fish-fed control, BSFL25 and BSFL50 diets (P < 0.05). Although numerical differences were recorded in the fish whole-body proximate composition, crude protein and moisture content were not much affected by the different dietary treatments. Essential amino acids including arginine, histidine, lysine and methionine were found to be higher in the whole body of fish-fed BSFL100 diet. Broken line regression analysis of average WG showed an optimum FM replacement level of 28.4% with BSFL meal. Therefore, the present experiment clearly demonstrates that the maximal dietary inclusion level of BSFL meal as FM protein replacer for the optimum growth of juvenile barramundi reared in freshwater could be greater than 28.4% but less than 50%, without any adverse effects on the fish whole-body proximate and amino acid composition

    Bilateral Assessment of Functional Tasks for Robot-assisted Therapy Applications

    Get PDF
    This article presents a novel evaluation system along with methods to evaluate bilateral coordination of arm function on activities of daily living tasks before and after robot-assisted therapy. An affordable bilateral assessment system (BiAS) consisting of two mini-passive measuring units modeled as three degree of freedom robots is described. The process for evaluating functional tasks using the BiAS is presented and we demonstrate its ability to measure wrist kinematic trajectories. Three metrics, phase difference, movement overlap, and task completion time, are used to evaluate the BiAS system on a bilateral symmetric (bi-drink) and a bilateral asymmetric (bi-pour) functional task. Wrist position and velocity trajectories are evaluated using these metrics to provide insight into temporal and spatial bilateral deficits after stroke. The BiAS system quantified movements of the wrists during functional tasks and detected differences in impaired and unimpaired arm movements. Case studies showed that stroke patients compared to healthy subjects move slower and are less likely to use their arm simultaneously even when the functional task requires simultaneous movement. After robot-assisted therapy, interlimb coordination spatial deficits moved toward normal coordination on functional tasks

    Mitochondrial DNA Copy Number Is Associated with Breast Cancer Risk

    Get PDF
    Mitochondrial DNA (mtDNA) copy number in peripheral blood is associated with increased risk of several cancers. However, data from prospective studies on mtDNA copy number and breast cancer risk are lacking. We evaluated the association between mtDNA copy number in peripheral blood and breast cancer risk in a nested case-control study of 183 breast cancer cases with pre-diagnostic blood samples and 529 individually matched controls among participants of the Singapore Chinese Health Study. The mtDNA copy number was measured using real time PCR. Conditional logistic regression analyses showed that there was an overall positive association between mtDNA copy number and breast cancer risk (Ptrend = 0.01). The elevated risk for higher mtDNA copy numbers was primarily seen for women with <3 years between blood draw and cancer diagnosis; ORs (95% CIs) for 2nd, 3rd, 4th, and 5th quintile of mtDNA copy number were 1.52 (0.61, 3.82), 2.52 (1.03, 6.12), 3.12 (1.31, 7.43), and 3.06 (1.25, 7.47), respectively, compared with the 1st quintile (Ptrend = 0.004). There was no association between mtDNA copy number and breast cancer risk among women who donated a blood sample ≥3 years before breast cancer diagnosis (Ptrend = 0.41). This study supports a prospective association between increased mtDNA copy number and breast cancer risk that is dependent on the time interval between blood collection and breast cancer diagnosis. Future studies are warranted to confirm these findings and to elucidate the biological role of mtDNA copy number in breast cancer risk. © 2013 Thyagarajan et al

    Neutral Gauge Boson Contributions to the Dimuon Charge Asymmetry in B Decays

    Full text link
    Recently, the D0 Collaboration measured the CP-violating like-sign dimuon charge asymmetry in neutral B decays, finding a 3.2sigma difference from the standard-model (SM) prediction. A non-SM charge asymmetry a_sl^s suggests a new-physics (NP) contribution to Bs-Bsbar mixing. In this case, in order to explain the measured value of a_sl^s within its 1sigma range, NP must be present in Gamma_12^s, the absorptive part of the mixing. In this paper, we examine whether such an explanation is possible in models with flavor-changing Z (ZFCNC) or Z' (Z'FCNC) gauge bosons. The models must also reproduce the measured values of the indirect CP asymmetry S_psi-phi in Bs -> J/psi phi, and Delta Gamma_s, the Bs-Bsbar width difference. We find that the ZFCNC model cannot reproduce the present measured values of S_psi-phi and a_sl^s within their 1sigma ranges. On the other hand, in the Z'FCNC model, the values of all three observables can be simultaneously reproduced.Comment: 18 pages, 7 figures, JHEP format. Some ZFCNC equations corrected, ZFCNC analysis redone, references added, conclusions unchange
    corecore