310 research outputs found

    Gravitational resonance spectroscopy with an oscillating magnetic field gradient in the GRANIT flow through arrangement

    Get PDF
    Gravitational resonance spectroscopy consists in measuring the energy spectrum of bouncing ultracold neutrons above a mirror by inducing resonant transitions between different discrete quantum levels. We discuss how to induce the resonances with a flow through arrangement in the GRANIT spectrometer, excited by an oscillating magnetic field gradient. The spectroscopy could be realized in two distinct modes (so called DC and AC) using the same device to produce the magnetic excitation. We present calculations demonstrating the feasibility of the newly proposed AC mode

    Lessons from the decoupling limit of Horava gravity

    Full text link
    We consider the so-called "healthy" extension of Horava gravity in the limit where the Stuckelberg field decouples from the graviton. We verify the alleged strong coupling problem in this limit, under the assumption that no large dimensionless parameters are put in by hand. This follows from the fact that the dispersion relation for the Stuckelberg field does not have the desired z = 3 anisotropic scaling in the UV. To get the desired scaling and avoid strong coupling one has to introduce a low scale of Lorentz violation and retain some coupling between the graviton and the Stuckelberg field. We also make use of the foliation preserving symmetry to show how the Stuckelberg field couples to some violation of energy conservation. We source the Stuckelberg field using a point particle with a slowly varying mass and show that two such particles feel a constant attractive force. In this particular example, we see no Vainshtein effect, and violations of the Equivalence Principle. The latter is probably generic to other types of source and could potentially be used to place lower bounds on the scale of Lorentz violation.Comment: 18 pages, 1 figure. Version to appear in JHEP. Conclusions with respect to strong coupling modified - our strong coupling analysis does not apply to a low scale of Lorentz violation. Expanded Equivalence Principle violation discussion, noting it presents a challenge to low scale Lorentz violation, exactly the scenario designed to cure strong coupling. Other minor corrections and references adde

    The anatomical limits of the posterior vaginal vault toward its use as route for intra-abdominal procedures

    Get PDF
    Background: The use of natural openings for abdominal surgery started at the beginning of the 21th century. A trans-Douglas endoscopic device has been designed to perform most of the intra-abdominal operations in women through the pouch of Douglas. The posterior vaginal vault is limited in size and could be damaged by an oversized instrument. This study investigates the optimal dimensions of the instrument by measuring the limiting factor in the passage. Methods: In ten female embalmed bodies the transversal and sagittal diameter of the fornix posterior vaginalis was measured by two observers. The pouch of Douglas was filled to its maximal capacity with mouldable latex through an open abdomen. By internal vaginal examination the connective tissue borders of the fornix posterior were palpated and the impression in the cast was measured. The mean value of these two diameters was evaluated in this study. The level of agreement between the observers was calculated. Results: The mean fornix posterior diameter was 2.6 cm (standard deviation, SD 0.5 cm) with a range of 2.0-3.4 cm. The mean difference between the two observers of all measurements was 0.08 cm (not significant). Both observers had an acceptable intraobserver variation. The interobserver agreement was excellent. Conclusion: Instruments with dimensions within the measured limits can be used safely for intra-abdominal operations via the natural orifice of the vagina

    Unwinding of a cholesteric liquid crystal and bidirectional surface anchoring

    Get PDF
    We examine the influence of bidirectional anchoring on the unwinding of a planar cholesteric liquid crystal induced by the application of a magnetic field. We consider a liquid crystal layer confined between two plates with the helical axis perpendicular to the substrates. We fixed the director twist on one boundary and allow for bidirectional anchoring on the other by introducing a high-order surface potential. By minimizing the total free energy for the system, we investigate the untwisting of the cholesteric helix as the liquid crystal attempts to align with the magnetic field. The transitions between metastable states occur as a series of pitchjumps as the helix expels quarter or half-turn twists, depending on the relative sizes of the strength of the surface potential and the bidirectional anchoring. We show that secondary easy axis directions can play a significant role in the unwinding of the cholesteric in its transition towards a nematic, especially when the surface anchoring strength is large

    The Nab Experiment: A Precision Measurement of Unpolarized Neutron Beta Decay

    Get PDF
    Neutron beta decay is one of the most fundamental processes in nuclear physics and provides sensitive means to uncover the details of the weak interaction. Neutron beta decay can evaluate the ratio of axial-vector to vector coupling constants in the standard model, λ=gA/gV\lambda = g_A / g_V, through multiple decay correlations. The Nab experiment will carry out measurements of the electron-neutrino correlation parameter aa with a precision of ÎŽa/a=10−3\delta a / a = 10^{-3} and the Fierz interference term bb to ÎŽb=3×10−3\delta b = 3\times10^{-3} in unpolarized free neutron beta decay. These results, along with a more precise measurement of the neutron lifetime, aim to deliver an independent determination of the ratio λ\lambda with a precision of Ύλ/λ=0.03%\delta \lambda / \lambda = 0.03\% that will allow an evaluation of VudV_{ud} and sensitively test CKM unitarity, independent of nuclear models. Nab utilizes a novel, long asymmetric spectrometer that guides the decay electron and proton to two large area silicon detectors in order to precisely determine the electron energy and an estimation of the proton momentum from the proton time of flight. The Nab spectrometer is being commissioned at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source at Oak Ridge National Lab. We present an overview of the Nab experiment and recent updates on the spectrometer, analysis, and systematic effects.Comment: Presented at PPNS201

    Changing alpha With Time: Implications For Fifth-Force-Type Experiments And Quintessence

    Full text link
    If the recent observations suggesting a time variation of the fine structure constant are correct, they imply the existence of an ultra light scalar particle. This particle inevitably couples to nucleons through the \alpha-dependence of their masses and thus mediates an isotope-dependent long-range force. The strength of the coupling is within a couple of orders of magnitude from the existing experimental bounds for such forces. The new force can be potentially measured in the precision experimental tests of the equivalence principle. Due to an interesting coincidence of the required time-scales, the scalar filed in question can at the same time play the role of a quintessence field.Comment: 7 pages, Late

    New Upper Limit of Terrestrial Equivalence Principle Test for Rotating Extended Bodies

    Full text link
    Improved terrestrial experiment to test the equivalence principle for rotating extended bodies is presented, and a new upper limit for the violation of the equivalence principle is obtained at the level of 1.610-7% \times 10^{\text{-7}}, which is limited by the friction of the rotating gyroscope. It means the spin-gravity interaction between the extended bodies has not been observed at this level.Comment: 4 page

    The fundamental constants and their variation: observational status and theoretical motivations

    Full text link
    This article describes the various experimental bounds on the variation of the fundamental constants of nature. After a discussion on the role of fundamental constants, of their definition and link with metrology, the various constraints on the variation of the fine structure constant, the gravitational, weak and strong interactions couplings and the electron to proton mass ratio are reviewed. This review aims (1) to provide the basics of each measurement, (2) to show as clearly as possible why it constrains a given constant and (3) to point out the underlying hypotheses. Such an investigation is of importance to compare the different results, particularly in view of understanding the recent claims of the detections of a variation of the fine structure constant and of the electron to proton mass ratio in quasar absorption spectra. The theoretical models leading to the prediction of such variation are also reviewed, including Kaluza-Klein theories, string theories and other alternative theories and cosmological implications of these results are discussed. The links with the tests of general relativity are emphasized.Comment: 56 pages, l7 figures, submitted to Rev. Mod. Phy
    • 

    corecore