45 research outputs found
PDE Modeling of a Microfluidic Thermal Process for Genetic Analysis Application
This paper details the infinite dimensional dynamics of a prototype microfluidic thermal process that is used for genetic analysis purposes. Highly effective infinite dimensional dynamics, in addition to collocated sensor and actuator architecture, require the development of a precise control framework to meet the very tight performance requirements of this system, which are not fully attainable through conventional lumped modeling and controller design approaches. The general partial differential equations describing the dynamics of the system are separated into steady-state and transient parts which are derived for a carefully chosen three-dimensional axisymmetric model. These equations are solved analytically, and the results are verified using an experimentally verified precise finite element method (FEM) model. The final combined result is a framework for designing a precise tracking controller applicable to the selected lab-on-a-chip device
Polymeric rapid prototyping for inexpensive and portable medical diagnostics
Tianchi Ma, Victoria Northrup, Andrew O. Fung, D. Moira Glerum, Christopher J. Backhouse, "Polymeric rapid prototyping for inexpensive and portable medical diagnostics", Proc. SPIE 8412, Photonics North 2012, 84120B (24 October 2012); doi: 10.1117/12.2001470. Copyright 2012, Society of Photo Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. https://doi.org/10.1117/12.2001470The advent of inexpensive CO2 laser systems has led to a wide range of demonstrations of microfabricated lab on chip systems built of acrylic. However, there has been little application of these systems to building microfluidics for DNA analysis. In this work we explore the use of CO2 laser systems for building microfluidics for DNA analysis and relate the artifacts of the fabrication technology to the performance of the system. We show that surface roughness that leads to significant constrictions in the separation channel provides an upper limit of the size of DNA that can be analysed. Below that upper limit, the resolution of the chip is strongly affected by the degree to which the separation channel is exposed to redeposited by-products of the ablation process. We show that by controlling these effects we are reliably able to discern two types of PCR product as a test representative of a real application. By being able to do this is in microfluidic devices the size of a postage stamp we have shown that we can now use CO2 laser systems for the development of extremely inexpensive diagnostic systems using a rapid prototyping approach.Natural Sciences and Engineering Research Council of CanadaTeledyne-DALS
Recommended from our members
Highly selective and solvent-dependent reduction of Nitrobenzene to N-phenylhydroxylamine, azoxybenzene, and aniline catalyzed by phosphino-modified polymer immobilized ionic liquid-stabilized AuNPs
Gold nanoparticles stabilized by phosphine-decorated polymer immobilized ionic liquids (AuNP@PPh2-PIILP) is an extremely efficient multiproduct selective catalyst for the sodium borohydride-mediated reduction of nitrobenzene giving N-phenylhydroxylamine, azoxybenzene, or aniline as the sole product under mild conditions and a very low catalyst loading. The use of a single nanoparticle-based catalyst for the partial and complete reduction of nitroarenes to afford three different products with exceptionally high selectivities is unprecedented. Under optimum conditions, thermodynamically unfavorable N-phenylhydroxylamine can be obtained as the sole product in near quantitative yield in water, whereas a change in reaction solvent to ethanol results in a dramatic switch in selectivity to afford azoxybenzene. The key to obtaining such a high selectivity for N-phenylhydroxylamine is the use of a nitrogen atmosphere at room temperature as reactions conducted under an inert atmosphere occur via the direct pathway and are essentially irreversible, while reactions in air afford significant amounts of azoxy-based products by virtue of competing condensation due to reversible formation of N-phenylhydroxylamine. Ultimately, aniline can also be obtained quantitatively and selectively by adjusting the reaction temperature and time accordingly. Introduction of PEG onto the polyionic liquid resulted in a dramatic improvement in catalyst efficiency such that N-phenylhydroxylamine could be obtained with a turnover number (TON) of 100 000 (turnover frequency (TOF) of 73 000 h–1, with >99% selectivity), azoxybenzene with a TON of 55 000 (TOF of 37 000 h–1 with 100% selectivity), and aniline with a TON of 500 000 (TOF of 62 500 h–1, with 100% selectivity). As the combination of ionic liquid and phosphine is required to achieve high activity and selectivity, further studies are currently underway to explore whether interfacial electronic effects influence adsorption and thereby selectivity and whether channeling of the substrate by the electrostatic potential around the AuNPs is responsible for the high activity. This is the first report of a AuNP-based system that can selectively reduce nitroarenes to either of two synthetically important intermediates as well as aniline and, in this regard, is an exciting discovery that will form the basis to develop a continuous flow process enabling facile scale-up
Science and Ideology in Economic, Political, and Social Thought
This paper has two sources: One is my own research in three broad areas: business cycles, economic measurement and social choice. In all of these fields I attempted to apply the basic precepts of the scientific method as it is understood in the natural sciences. I found that my effort at using natural science methods in economics was met with little understanding and often considerable hostility. I found economics to be driven less by common sense and empirical evidence, then by various ideologies that exhibited either a political or a methodological bias, or both. This brings me to the second source: Several books have appeared recently that describe in historical terms the ideological forces that have shaped either the direct areas in which I worked, or a broader background. These books taught me that the ideological forces in the social sciences are even stronger than I imagined on the basis of my own experiences.
The scientific method is the antipode to ideology. I feel that the scientific work that I have done on specific, long standing and fundamental problems in economics and political science have given me additional insights into the destructive role of ideology beyond the history of thought orientation of the works I will be discussing
Robust thermal control for CMOS-based lab-on-chip systems
The need for precise temperature control at small scales has provided a formidable challenge to the lab-on-chip community. It requires, at once, good thermal conductivity for high speed operation, good thermal isolation for low power consumption and the ability to have small (mm-scale) thermally independent regions on the same substrate. Most importantly, and, in addition to these conflicting requirements, there is a need to accurately measure the temperature of the active region without the need for device-to-device calibrations. We have developed and tested a design that enables thermal control of lab-on-chip devices atop silicon substrates in a way that could be integrated with the standard methods of mass-manufacture used in the electronics industry (i.e. CMOS). This is a significant step towards a single-chip lab-on-chip solution, one in which the microfluidics, high voltage electronics, optoelectronics, instrumentation electronics, and the world-chip interface are all integrated on a single substrate with multiple, independent, thermally-controlled regions based on active heating and passive cooling.Natural Sciences and Engineering Research Canada (NSERC)Teledyne-DALSA Semiconducto
BHPR research: qualitative1. Complex reasoning determines patients' perception of outcome following foot surgery in rheumatoid arhtritis
Background: Foot surgery is common in patients with RA but research into surgical outcomes is limited and conceptually flawed as current outcome measures lack face validity: to date no one has asked patients what is important to them. This study aimed to determine which factors are important to patients when evaluating the success of foot surgery in RA Methods: Semi structured interviews of RA patients who had undergone foot surgery were conducted and transcribed verbatim. Thematic analysis of interviews was conducted to explore issues that were important to patients. Results: 11 RA patients (9 ♂, mean age 59, dis dur = 22yrs, mean of 3 yrs post op) with mixed experiences of foot surgery were interviewed. Patients interpreted outcome in respect to a multitude of factors, frequently positive change in one aspect contrasted with negative opinions about another. Overall, four major themes emerged. Function: Functional ability & participation in valued activities were very important to patients. Walking ability was a key concern but patients interpreted levels of activity in light of other aspects of their disease, reflecting on change in functional ability more than overall level. Positive feelings of improved mobility were often moderated by negative self perception ("I mean, I still walk like a waddling duck”). Appearance: Appearance was important to almost all patients but perhaps the most complex theme of all. Physical appearance, foot shape, and footwear were closely interlinked, yet patients saw these as distinct separate concepts. Patients need to legitimize these feelings was clear and they frequently entered into a defensive repertoire ("it's not cosmetic surgery; it's something that's more important than that, you know?”). Clinician opinion: Surgeons' post operative evaluation of the procedure was very influential. The impact of this appraisal continued to affect patients' lasting impression irrespective of how the outcome compared to their initial goals ("when he'd done it ... he said that hasn't worked as good as he'd wanted to ... but the pain has gone”). Pain: Whilst pain was important to almost all patients, it appeared to be less important than the other themes. Pain was predominately raised when it influenced other themes, such as function; many still felt the need to legitimize their foot pain in order for health professionals to take it seriously ("in the end I went to my GP because it had happened a few times and I went to an orthopaedic surgeon who was quite dismissive of it, it was like what are you complaining about”). Conclusions: Patients interpret the outcome of foot surgery using a multitude of interrelated factors, particularly functional ability, appearance and surgeons' appraisal of the procedure. While pain was often noted, this appeared less important than other factors in the overall outcome of the surgery. Future research into foot surgery should incorporate the complexity of how patients determine their outcome Disclosure statement: All authors have declared no conflicts of interes
PDE Modeling of a Microfluidic Thermal Process for Genetic Analysis Application
This paper details the infinite dimensional dynamics of a prototype microfluidic thermal process that is used for genetic analysis purposes. Highly effective infinite dimensional dynamics, in addition to collocated sensor and actuator architecture, require the development of a precise control framework to meet the very tight performance requirements of this system, which are not fully attainable through conventional lumped modeling and controller design approaches. The general partial differential equations describing the dynamics of the system are separated into steady-state and transient parts which are derived for a carefully chosen three-dimensional axisymmetric model. These equations are solved analytically, and the results are verified using an experimentally verified precise finite element method (FEM) model. The final combined result is a framework for designing a precise tracking controller applicable to the selected lab-on-a-chip device