3,000 research outputs found

    Ion-acoustic solitons in warm magnetoplasmas with super-thermal electrons

    Full text link
    In this work, the phenomenon of formation of localised electrostatic waves (ESW) or soliton is considered in a warm magnetoplasma with the possibility of non-thermal electron distribution. The parameter regime considered here is relevant in case of magnetospheric plasmas. We show that deviation from a usual relaxed Maxwellian distribution of the electron population has a significant bearing in the allowed parameter regime, where these ESWs can be found. We further consider the presence of more than one electron temperature, which is inspired by recent space-based observations[key-2].Comment: 10 pages, 5 figure

    AAUOKHYB -1 : An excellent Okra hybrid developed by Assam Agricultural University (AAU) suitable for diverse agro-climatic situation of North East India

    Get PDF
    A hybrid development programme on okra (Abelmoschus esculentus) was undertaken at the Assam Agricultural University (AAU), Jorhat. The work included collection and evaluation of okra germplasm, identification of parents for hybridization, selfing of identified parental lines, making crosses and production of hybrid seeds, testing of hybrids for yield and resistance to Yellow Vein Mosaic Virus (YVMV) disease, adaptability under diverse agro-climatic condition and testing in all India trials. The programme resulted in development and identification of excellent Okra hybrid AAUOKHYB-1 in 2017.  The performance of the hybrid was very good under diverse agro-climatic conditions yielding about 162.0 q/ha fruit yield which is 32.5% higher than the best commercial check Arka Anamika. The hybrid showed resistant (R) reaction to YVMV disease. A wide range of heterosis upto 43% was exhibited by the hybrid in different vegetable research centers of the country as compared to the best check variety

    Effect of some biocontrol agents against root-knot nematode (Meloidogyne incognita race2)

    Full text link
    Culture filtrate of four rhizospheric fungi and four biocontrol agents were studied in vitro for their efficacy against Meloidogyne incognita race 2. The per cent mortality and egg hatching inhibition was proportional to the concentration of culture filtrate and the duration of exposure period. Culture filtrates of Trichoderma viride, Trichoderma harzianum, Trichoderma sp., Fusarium sp., Penicillium sp. and Aspergillus sp. significantly induced inhibition of egg hatching and mortality of Meloidogyne incognita race 2.The highest percentage of inhibition of egg hatching and juvenile mortality was recorded in Trichoderma harzianum followed by Trichoderma viride and Trichoderma sp

    A Study on the Thermal Behaviours of Eri, Muga and Pat Fibres

    Get PDF

    Pulsed x-rays dose measurements from a hundred joules plasma focus device

    Get PDF
    Indexación: Scopus.Present work is aimed to perform dosimetric measurements to characterize dosis obtained from pulsed x-rays emitted from a hundred joules plasma focus device PF-400J using thermoluminescent dosimeters (TLD-100). Two dosimeter arrays (containing 21 dosimeters in each) were used. One of the arrays was kept inside the PF-400J vacuum chamber and other outside the vacuum chamber, simultaneously. It was found that dosis obtained from the inside array (∼200.7 mGy) were hundred times larger than the outside array (∼1.1 mGy) for hundred pulses of x-rays. Later, the vacuum window of PF-400J, which was made of 1 mm aluminum, was replaced by a plastic window and a similar dosimeter array was kept outside the chamber over the plastic window. With this arrangement, the obtained doses (100 pulses of x-rays) were of the same order of magnitude (∼106 mGy) as it was inside the vacuum chamber. Later, a lead piece was inserted inside the hollow anode of PF-400J, which increased dose (∼250 mGy) per hundred pulses of x-ray outside the vacuum chamber using plastic vacuum window. Our results suggest that PF-400J could be a useful device to study low dose pulsed radiation effects on cancer cell lines in in vitro experiments. © Published under licence by IOP Publishing Ltd.The work is supported by grant ACT-1115, CONICYT, Chile.https://iopscience.iop.org/article/10.1088/1742-6596/1043/1/01204

    Analysis of Deterioration in a Plasma Focus Device

    Get PDF
    Indexación: Scopus.The Plasma Focus (PF) is a kind of dense transient plasmas in with high-pulsed voltage. To produce devices for eld application it is necessary to obtain PF equipment able to operate for a long period of time. Thus, a reliability analysis is indispensable. In this work a reliability analysis program for plasma focus devices is presented. The program considers a criticality analysis using Failure Modes and Effects Criticality Analysis (FMECA) to identify the most important failure modes of the system. Said failure modes are studied operating the Plasma Focus for many cycles, obtaining from them the characteristic curves of V(t) and İ(t). Feature Extraction (FE) techniques are applied to obtain a list of parameters that correlate to the degrading process. Furthermore, Machine Learning tools are used to learn from the obtained data, linking the changes in these parameters during its life cycle to the decay of the system in hope for future implementation of a predictive maintenance system and a reference for data analysis and prediction in PFs. The study was applied to a portable plasma focus device operated at 2 joules of stored energy. © Published under licence by IOP Publishing Ltd.The work is supported by IAEA CRP contract 20370 and by grant ACT-1115, CONICYT, Chile.https://iopscience.iop.org/article/10.1088/1742-6596/1043/1/01204

    Zoneamento climático da ferrugem do eucalipto para o Estado do Paraná.

    Get PDF
    Edição do 37º Congresso Paulista de Fitopatologia. CD-ROM. Resumo 140

    Hundred joules plasma focus device as a potential pulsed source for in vitro cancer cell irradiation

    Get PDF
    Indexación: Web of Science; Scopus.Plasma focus devices may arise as useful source to perform experiments aimed to study the effects of pulsed radiation on human cells in vitro. In the present work, a table top hundred joules plasma focus device, namely "PF-400J", was adapted to irradiate colorectal cancer cell line, DLD-1. For pulsed x-rays, the doses (energy absorbed per unit mass, measured in Gy) were measured using thermoluminescence detectors (TLD-100 dosimeters). The neutron fluence and the average energy were used to estimate the pulsed neutron doses. Fifty pulses of x-rays (0.12 Gy) and fifty pulses of neutrons (3.5 μGy) were used to irradiate the cancer cells. Irradiation-induced DNA damage and cell death were assessed at different time points after irradiation. Cell death was observed using pulsed neutron irradiation, at ultralow doses. Our results indicate that the PF-400J can be used for in vitro assessment of the effect of pulsed radiation in cancer cell research.http://recursosbiblioteca.unab.cl:2296/doi/pdf/10.1063/1.499465
    corecore