189 research outputs found

    Cherenkov luminescence measurements with digital silicon photomultipliers: a feasibility study.

    Get PDF
    BackgroundA feasibility study was done to assess the capability of digital silicon photomultipliers to measure the Cherenkov luminescence emitted by a β source. Cherenkov luminescence imaging (CLI) is possible with a charge coupled device (CCD) based technology, but a stand-alone technique for quantitative activity measurements based on Cherenkov luminescence has not yet been developed. Silicon photomultipliers (SiPMs) are photon counting devices with a fast impulse response and can potentially be used to quantify β-emitting radiotracer distributions by CLI.MethodsIn this study, a Philips digital photon counting (PDPC) silicon photomultiplier detector was evaluated for measuring Cherenkov luminescence. The PDPC detector is a matrix of avalanche photodiodes, which were read one at a time in a dark count map (DCM) measurement mode (much like a CCD). This reduces the device active area but allows the information from a single avalanche photodiode to be preserved, which is not possible with analog SiPMs. An algorithm to reject the noisiest photodiodes and to correct the measured count rate for the dark current was developed.ResultsThe results show that, in DCM mode and at (10-13) °C, the PDPC has a dynamic response to different levels of Cherenkov luminescence emitted by a β source and transmitted through an opaque medium. This suggests the potential for this approach to provide quantitative activity measurements. Interestingly, the potential use of the PDPC in DCM mode for direct imaging of Cherenkov luminescence, as a opposed to a scalar measurement device, was also apparent.ConclusionsWe showed that a PDPC tile in DCM mode is able to detect and image a β source through its Cherenkov radiation emission. The detector's dynamic response to different levels of radiation suggests its potential quantitative capabilities, and the DCM mode allows imaging with a better spatial resolution than the conventional event-triggered mode. Finally, the same acquisition procedure and data processing could be employed also for other low light levels applications, such as bioluminescence

    Distribution of deer keds (Diptera: Hippoboscidae) in free-living cervids of the Tuscan-Emilian Apennines, central Italy, and establishment of the allochthonous ectoparasite Lipoptena fortisetosa

    Get PDF
    Lipoptena fortisetosa and L. cervi are hematophagous ectoparasites belonging to the Hippoboscidae family and preferentially living on cervids. In recent years, they have received specific attention due to the great increase in the abundance of their host species, and to their medical and veterinary importance as possible vectors of pathogens harmful to humans and animals. The aim of this study was to investigate the parasitism level of both of these flies on their main hosts in Italy, which are red deer, fallow deer, and roe deer, and to highlight a possible preference for a species, sex, or age class among the hosts. Deer keds were collected by examining 326 cervids hunted in the Tuscan-Emilian Apennines. Outcomes showed that L. fortisetosa has greatly spread throughout the study area, where it competes with the autochthonous L. cervi. Moreover, red deer was the favored host species of both ectoparasites, while different preferences for host sex and age classes were observed in the two hippoboscids. The regular monitoring of deer ked populations, especially the allochthonous L. fortisetosa, which is continuously spreading in Europe, is recommended to expand the knowledge on these parasitic species that are potentially dangerous to public health

    Colour preference of the deer ked Lipoptena fortisetosa (Diptera: Hippoboscidae)

    Get PDF
    SIMPLE SUMMARY: Insects use visual stimuli to find habitats, food, or a mate while moving around. This trait might be exploited to intercept flying insects to monitor their populations and reduce their presence. Among the various visual stimuli, colours are commonly used to attract insects. Lipoptena fortisetosa is a hematophagous deer ectoparasite native to Japan that has spread to several central European countries and was recently recorded in Italy. Measures to monitor and control L. fortisetosa would be helpful given its potential threat as a pathogen vector for animals and humans. The objective of this research was to assess the potential use of colour to attract and trap L. fortisetosa. The response of the winged adults was evaluated through an experimental trial carried out in a wooded area of Tuscany using differently coloured sticky panels as traps. Blue panels attracted the highest number while yellow panels showed the lowest performance. This preference for blue could be useful in the design of traps to reduce the population of this parasitic fly which, at certain times, can reach a very high density, causing annoyance to wildlife and humans visiting natural areas. ABSTRACT: Lipoptena fortisetosa, a deer ked native to Japan, has established itself in several European countries and was recently recorded in Italy. This hippoboscid ectoparasite can develop high density populations, causing annoyance to animals and concern regarding the potential risk of transmitting pathogens to humans. No monitoring or control methods for L. fortisetosa have been applied or tested up to now. This research evaluated the possible response of L. fortisetosa winged adults to different colours as the basis for a monitoring and control strategy. In the summer of 2020, a series of six differently coloured sticky panels were randomly set as traps in a wooded area used by deer for resting. The results indicated a clear preference of the deer ked for the blue panels that caught the highest number of flies during the experimental period. Lower numbers of flies were trapped on the red, green, black, and white panels, with the yellow panels recording the fewest captures. The response clearly demonstrates that this species displays a colour preference, and that coloured traps might be useful for monitoring and limiting this biting ectoparasite in natural areas harbouring wildlife and visited by people

    Analysis of time-profiles with in-beam PET monitoring in charged particle therapy

    Full text link
    Background: Treatment verification with PET imaging in charged particle therapy is conventionally done by comparing measurements of spatial distributions with Monte Carlo (MC) predictions. However, decay curves can provide additional independent information about the treatment and the irradiated tissue. Most studies performed so far focus on long time intervals. Here we investigate the reliability of MC predictions of space and time (decay rate) profiles shortly after irradiation, and we show how the decay rates can give an indication about the elements of which the phantom is made up. Methods and Materials: Various phantoms were irradiated in clinical and near-clinical conditions at the Cyclotron Centre of the Bronowice proton therapy centre. PET data were acquired with a planar 16x16 cm2^2 PET system. MC simulations of particle interactions and photon propagation in the phantoms were performed using the FLUKA code. The analysis included a comparison between experimental data and MC simulations of space and time profiles, as well as a fitting procedure to obtain the various isotope contributions in the phantoms. Results and conclusions: There was a good agreement between data and MC predictions in 1-dimensional space and decay rate distributions. The fractions of 11^{11}C, 15^{15}O and 10^{10}C that were obtained by fitting the decay rates with multiple simple exponentials generally agreed well with the MC expectations. We found a small excess of 10^{10}C in data compared to what was predicted in MC, which was clear especially in the PE phantom.Comment: 9 pages, 5 figures, 1 table. Proceedings of the 20th International Workshop on Radiation Imaging Detectors (iWorid2018), 24-28 June 2018, Sundsvall, Swede

    Monitoring Proton Therapy Through In-Beam PET: An Experimental Phantom Study

    Get PDF
    In this paper, we investigate the use of a positron emission tomography (PET) system to monitor the proton therapy. The monitoring procedure is based on the comparison between the β+ activity generated in the irradiated volume during the treatment, with the β+ activity distribution obtained with Monte Carlo (MC) simulation. The dedicated PET system is a dual head detection system; each head is composed of nine scintillating LYSO crystal matrices read out independently with a custom modularized acquisition system. Our experimental data were acquired at the Cyclotron Centre Bronowice, Institute Nuclear Physics in Kraków, Poland, and were simulated with the FLUKA MC code. Homogeneous and heterogeneous plastic phantoms were irradiated with monoenergetic 130 MeV protons. The capabilities of our PET system to distinguish different irradiated materials were investigated, and the proton pencil-beams were used as probes. Our focus was to analyze the activity width and the total activity event number in several cases. Irradiations were performed using either single pencil-beams one at a time, or two pencil-beams during the same data taking. The comparison of 1-D activity profile for experimental data and MC simulation were always in good agreement showing that, the treatment quality assessment in proton therapy can be based on β+ activity measurements

    FOOT: a new experiment to measure nuclear fragmentation at intermediate energies

    Get PDF
    Summary: Charged particle therapy exploits proton or 12C beams to treat deep-seated solid tumors. Due to the advantageous characteristics of charged particles energy deposition in matter, the maximum of the dose is released to the tumor at the end of the beam range, in the Bragg peak region. However, the beam nuclear interactions with the patient tissues induces fragmentation both of projectile and target nuclei and needs to be carefully taken into account. In proton treatments, target fragmentation produces low energy, short range fragments along all the beam range, which deposit a non negligible dose in the entry channel. In 12C treatments the main concern is represented by long range fragments due to beam fragmentation that release their dose in the healthy tissues beyond the tumor. The FOOT experiment (FragmentatiOn Of Target) of INFN is designed to study these processes, in order to improve the nuclear fragmentation description in next generation Treatment Planning Systems and the treatment plans quality. Target (16O and 12C nuclei) fragmentation induced by –proton beams at therapeutic energies will be studied via an inverse kinematic approach, where 16O and 12C therapeutic beams impinge on graphite and hydrocarbon targets to provide the nuclear fragmentation cross section on hydrogen. Projectile fragmentation of 16O and 12C beams will be explored as well. The FOOT detector includes a magnetic spectrometer for the fragments momentum measurement, a plastic scintillator for ΔE and time of flight measurements and a crystal calorimeter to measure the fragments kinetic energy. These measurements will be combined in order to make an accurate fragment charge and isotopic identification. Keywords: Hadrontherapy, Nuclear fragmentation cross sections, Tracking detectors, Scintillating detector
    • …
    corecore