19,572 research outputs found

    Trapped in the Greenhouse?: Regulating Carbon Dioxide after FDA v. Brown & Williamson Tobacco Corp.

    Get PDF
    An architecture for actionbased planning and cooperation between multiple AI-agents based on the GOAP-architecture was developed together with a system to be used in advanced AI-courses at Linköping unversity. The architecture was implemented in this system to show the possibilities of our work

    Human sensitivity to gearshift loads

    Get PDF
    This paper describes an investigation of the ability of humans to distinguish different levels of gearlever load. A test rig with a forward-backward moving gearshift lever was constructed using the typical interior dimensions of European B segment automobiles. The rig used a system of weights and pulleys to provide a load which could be varied in steps of 1%. Four reference loads were chosen which were considered representative of automotive gearshift operation: 0.5, 1.0, 2.0 and 5.0 kg. Twenty subjects took part in the study. Using a variation on the psychophysical method of limits, the subjects were asked to respond whether a test load was heavier or lighter than a reference load. The Weber Fraction was found to decrease monotonically from a value of 0.036 for the 0.5 kg reference load to a value of 0.029 at the 5.0 kg reference load. The average value across all reference loads was 0.032. Measurements of the gearshift force made by means of a knob containing a load cell suggested that the variation in the measured Weber Fraction might be attributable to the time behaviour of the force exchanged between the human subject and the control surface

    Characterising and Testing Deep UV LEDs for Use in Space Applications

    Full text link
    Deep ultraviolet (DUV) light sources are used to neutralise isolated test masses in highly sensitive space-based gravitational experiments. An example is the LISA Pathfinder charge management system, which uses low-pressure mercury lamps. A future gravitational-wave observatory such as eLISA will use UV light-emitting diodes (UV LEDs), which offer numerous advantages over traditional discharge lamps. Such devices have limited space heritage but are are now available from a number of commercial suppliers. Here we report on a test campaign that was carried out to quantify the general properties of three types of commercially available UV LEDs and demonstrate their suitability for use in space. Testing included general electrical and UV output measurements, spectral stability, pulsed performance, temperature dependence as well as thermal vacuum, radiation and vibration survivability

    Weierstrass representations for harmonic morphisms on Euclidean spaces and spheres

    Full text link
    We construct large families of harmonic morphisms which are holomorphic with respect to Hermitian structures by finding heierarchies of Weierstrass-type representations. This enables us to find new examples of complex-valued harmonic morphisms from Euclidean spaces and spheres.Comment: Minor revision adding example. Latex 2.09. 14 page

    Ostwald ripening theory

    Get PDF
    An approximate analytical technique for extracting the concentration dependence of the interdiffusion coefficient was derived from diffusion measurements carried out with the diaphragm cell. The systematic error incurred in using the technique was estimated and found to be no greater than the random error ordinarily encountered in these experiments

    Iodinated contrast media and cerebral hemorrhage after intravenous thrombolysis

    Get PDF
    <p>Background and Purpose: Iodinated contrast is increasingly used in CT perfusion or angiographic examinations in acute stroke. Increased risk of intracranial hemorrhage (ICH) complicating microcatheter contrast injections has recently been reported in the second Interventional Management of Stroke (IMS 2) trial with contrast toxicity potentially contributory.</p> <p>Methods: We reviewed clinical and radiological data on all patients treated with intravenous alteplase at a single center between May 2003 and November 2008.</p> <p>Results: Of 312 patients treated with intravenous alteplase, 69 (22.1%) received intravenous iodinated contrast in volumes between 50 and 150 mL. Incidence of symptomatic ICH defined as per European Cooperative Acute Stroke Study 2 was 16 of 312 (5.1%; 95% CI, 2.7% to 7.6%); among patients not given contrast, it was 12 of 243 (4.9%; 2.2% to 7.7%) compared with 4 of 69 (5.8%; 0.3% to 11.3%) in those given contrast. Incidence of symptomatic ICH defined as per Safe Implementation of Thrombolysis in Stroke-MOnitoring Study (SITS-MOST) criteria was 12 of 312 (3.9%; 1.7% to 6%), 9 of 243 (3.7%; 1.3% to 6%) among those not given contrast, and 3 of 69 (4.4%; 95% CI, -0.5% to 9.2%) among those given contrast. Patients with symptomatic ICH were older, had higher pretreatment National Institutes of Health Stroke Scale, and blood glucose than those without symptomatic ICH. In logistic regression analysis, pretreatment blood glucose was the only significant predictor of symptomatic ICH by either definition (OR, 1.23; 95% CI, 1.03 to 1.48 per mmol/L increment; P=0.024). Contrast administration or dose was not associated with symptomatic ICH.</p> <p>Conclusions: Intravenous iodinated contrast in doses typically required for CT angiography and perfusion imaging was not associated with symptomatic intracranial hemorrhage in patients treated with alteplase.</p&gt

    Regional Ocean Governance: A Look at California

    Get PDF
    corecore