189 research outputs found

    Mass models from high-resolution HI data of the dwarf galaxy NGC 1560

    Full text link
    We present HI observations performed at the GMRT of the nearby dwarf galaxy NGC 1560. This Sd galaxy is well-known for a distinct "wiggle" in its rotation curve. Our new observations have twice the resolution of the previously published HI data. We derived the rotation curve by taking projection effects into account, and we verified the derived kinematics by creating model datacubes. This new rotation curve is similar to the previously published one: we confirm the presence of a clear wiggle. The main differences are in the innermost ~100 arcsec of the rotation curve, where we find slightly (<~ 5 km/s) higher velocities. Mass modelling of the rotation curve results in good fits using the core-dominated Burkert halo (which however does not reproduce the wiggle), bad fits using the a Navarro, Frenk & White halo, and good fits using MOND (Modified Newtonian Dynamics), which also reproduces the wiggle.Comment: Accepted for publication in MNRAS. 11 pages, 13 figures. High-resolution version available at http://users.ugent.be/~ggianfra/1560_final.pd

    Increased airway glucose increases airway bacterial load in hyperglycaemia.

    Get PDF
    Diabetes is associated with increased frequency of hospitalization due to bacterial lung infection. We hypothesize that increased airway glucose caused by hyperglycaemia leads to increased bacterial loads. In critical care patients, we observed that respiratory tract bacterial colonisation is significantly more likely when blood glucose is high. We engineered mutants in genes affecting glucose uptake and metabolism (oprB, gltK, gtrS and glk) in Pseudomonas aeruginosa, strain PAO1. These mutants displayed attenuated growth in minimal medium supplemented with glucose as the sole carbon source. The effect of glucose on growth in vivo was tested using streptozocin-induced, hyperglycaemic mice, which have significantly greater airway glucose. Bacterial burden in hyperglycaemic animals was greater than control animals when infected with wild type but not mutant PAO1. Metformin pre-treatment of hyperglycaemic animals reduced both airway glucose and bacterial load. These data support airway glucose as a critical determinant of increased bacterial load during diabetes

    Vertebral rotation measurement: a summary and comparison of common radiographic and CT methods

    Get PDF
    Current research has provided a more comprehensive understanding of Adolescent Idiopathic Scoliosis (AIS) as a three-dimensional spinal deformity, encompassing both lateral and rotational components. Apart from quantifying curve severity using the Cobb angle, vertebral rotation has become increasingly prominent in the study of scoliosis. It demonstrates significance in both preoperative and postoperative assessment, providing better appreciation of the impact of bracing or surgical interventions. In the past, the need for computer resources, digitizers and custom software limited studies of rotation to research performed after a patient left the scoliosis clinic. With advanced technology, however, rotation measurements are now more feasible. While numerous vertebral rotation measurement methods have been developed and tested, thorough comparisons of these are still relatively unexplored. This review discusses the advantages and disadvantages of six common measurement techniques based on technology most pertinent in clinical settings: radiography (Cobb, Nash-Moe, Perdriolle and Stokes' method) and computer tomography (CT) imaging (Aaro-Dahlborn and Ho's method). Better insight into the clinical suitability of rotation measurement methods currently available is presented, along with a discussion of critical concerns that should be addressed in future studies and development of new methods

    Measurement of vertebral rotation in adolescent idiopathic scoliosis with low-dose CT in prone position - method description and reliability analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To our knowledge there is no report in the literature on measurements of vertebral rotation with low-dose computed tomography (CT) in prone position.</p> <p>Aims</p> <p>To describe and test the reliability of this new method, compare it with other methods in use and evaluate the influence of body position on the degree of vertebral rotation measured by different radiological methods.</p> <p>Study design</p> <p>Retrospective study.</p> <p>Methods</p> <p>25 consecutive patients with adolescent idiopathic scoliosis scheduled for surgery (17 girls, 8 boys) aged 15 ± 2 years (mean ± SD) were included in the analysis of this study. The degree of the vertebral rotation was in all patients measured according to the method of Perdriolle on standing plain radiographs and on supine CT scanogram, and according to the method of Aaro and Dahlborn on axial CT images in prone position and on magnetic resonance imaging (MRI) in supine position. The measurements were done by one neuroradiologist at two different occasions. Bland and Altman statistical approach was used in the reliability assessment.</p> <p>Results</p> <p>The reliability of measuring vertebral rotation by axial CT images in prone position was almost perfect with an intraclass correlation coefficient of 0.95, a random error of the intraobserver differences of 2.3°, a repeatability coefficient of 3.2° and a coefficient of variation of 18.4%. Corresponding values for measurements on CT scanogram were 0.83, 5.1°, 7.2°, and 32.8%, respectively, indicating lower reliability of the latter modality and method. The degree of vertebral rotation measured on standing plain radiographs, prone CT scanogram, axial images on CT in prone position and on MRI in supine position were 25.7 ± 9.8°, 21.9 ± 8.3°, 17.4 ± 7.1°, and 16.1 ± 6.5°, respectively. The vertebral rotation measured on axial CT images in prone position was in average 7.5% larger than that measured on axial MRI in supine position.</p> <p>Conclusions</p> <p>This study has shown that measurements of vertebral rotation in prone position were more reliable on axial CT images than on CT scanogram. The measurement of vertebral rotation on CT (corrected to the pelvic tilt) in prone position imposes lower impact of the recumbent position on the vertebral rotation than did MRI in supine position. However, the magnitude of differences is of doubtful clinical significance.</p

    Development and Validation of Automated Magnetic Resonance Parkinsonism Index 2.0 to Distinguish Progressive Supranuclear Palsy-Parkinsonism From Parkinson's Disease

    Get PDF
    Background: Differentiating progressive supranuclear palsy-parkinsonism (PSP-P) from Parkinson's disease (PD) is clinically challenging. Objective: This study aimed to develop an automated Magnetic Resonance Parkinsonism Index 2.0 (MRPI 2.0) algorithm to distinguish PSP-P from PD and to validate its diagnostic performance in two large independent cohorts. Methods: We enrolled 676 participants: a training cohort (n&nbsp;=&nbsp;346; 43 PSP-P, 194 PD, and 109 control subjects) from our center and an independent testing cohort (n&nbsp;=&nbsp;330; 62 PSP-P, 171 PD, and 97 control subjects) from an international research group. We developed a new in-house algorithm for MRPI 2.0 calculation and assessed its performance in distinguishing PSP-P from PD and control subjects in both cohorts using receiver operating characteristic curves. Results: The automated MRPI 2.0 showed excellent performance in differentiating patients with PSP-P from patients with PD and control subjects both in the training cohort (area under the receiver operating characteristic curve [AUC]&nbsp;=&nbsp;0.93 [95% confidence interval, 0.89–0.98] and AUC&nbsp;=&nbsp;0.97 [0.93–1.00], respectively) and in the international testing cohort (PSP-P versus PD, AUC&nbsp;=&nbsp;0.92 [0.87–0.97]; PSP-P versus controls, AUC&nbsp;=&nbsp;0.94 [0.90–0.98]), suggesting the generalizability of the results. The automated MRPI 2.0 also accurately distinguished between PSP-P and PD in the early stage of the diseases (AUC&nbsp;=&nbsp;0.91 [0.84–0.97]). A strong correlation (r&nbsp;=&nbsp;0.91, P &lt; 0.001) was found between automated and manual MRPI 2.0 values. Conclusions: Our study provides an automated, validated, and generalizable magnetic resonance biomarker to distinguish PSP-P from PD. The use of the automated MRPI 2.0 algorithm rather than manual measurements could be important to standardize measures in patients with PSP-P across centers, with a positive impact on multicenter studies and clinical trials involving patients from different geographic regions. © 2022 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society

    Saccadic latency in hepatic encephalopathy: a pilot study

    Get PDF
    Hepatic encephalopathy is a common complication of cirrhosis. The degree of neuro-psychiatric impairment is highly variable and its clinical staging subjective. We investigated whether eye movement response times—saccadic latencies—could serve as an indicator of encephalopathy. We studied the association between saccadic latency, liver function and paper- and pencil tests in 70 patients with cirrhosis and 31 patients after liver transplantation. The tests included the porto-systemic encephalopathy (PSE-) test, critical flicker frequency, MELD score and ammonia concentration. A normal range for saccades was established in 31 control subjects. Clinical and biochemical parameters of liver, blood, and kidney function were also determined. Median saccadic latencies were significantly longer in patients with liver cirrhosis when compared to patients after liver transplantation (244 ms vs. 278 ms p < 0.001). Both patient groups had prolonged saccadic latency when compared to an age matched control group (175 ms). The reciprocal of median saccadic latency (μ) correlated with PSE tests, MELD score and critical flicker frequency. A significant correlation between the saccadic latency parameter early slope (σE) that represents the prevalence of early saccades and partial pressure of ammonia was also noted. Psychometric test performance, but not saccadic latency, correlated with blood urea and sodium concentrations. Saccadic latency represents an objective and quantitative parameter of hepatic encephalopathy. Unlike psychometric test performance, these ocular responses were unaffected by renal function and can be obtained clinically within a matter of minutes by non-trained personnel

    Cost-effectiveness of minimal interventional procedures for chronic mechanical low back pain: design of four randomised controlled trials with an economic evaluation

    Get PDF
    Background: Minimal interventional procedures are frequently applied in patients with mechanical low back pain which is defined as pain presumably resulting from single sources: facet, disc, sacroiliac joint or a combination of these. Usually, these minimal interventional procedures are an integral part of a multidisciplinary pain programme. A recent systematic review issued by the Dutch Health Insurance Council showed that the effectiveness of these procedures for the total group of patients with chronic low back pain is yet unclear and cost-effectiveness unknown. The aim of the study is to evaluate whether a multidisciplinary pain programme with minimal interventional procedures is cost-effective compared to the multidisciplinary pain programme alone for patients with chronic mechanical low back pain who did not respond to conservative primary care and were referred to a pain clinic. Methods. All patients with chronic low back pain who are referred to one of the 13 participating pain clinics will be asked to participate in an observational study. Patients with a suspected diagnosis of facet, disc or sacroiliac joint problems will receive a diagnostic block to confirm this diagnosis. If confirmed, they will be asked to participate in a Randomized Controlled Trial (RCT). For each single source a separate RCT will be conducted. Patients with a combination of facet, disc or sacroiliac joint problems will be invited for participation in a RCT as well. An economic evaluation from a societal perspective will be performed alongside these four RCTs. Patients will complete questionnaires at baseline, 3 and 6 weeks, 3, 6, 9 and 12 months after start of the treatment
    corecore