92 research outputs found
MLP: a MATLAB toolbox for rapid and reliable auditory threshold estimation
In this paper, we present MLP, a MATLAB toolbox enabling auditory
thresholds estimation via the adaptive Maximum Likelihood procedure proposed
by David Green (1990, 1993). This adaptive procedure is particularly appealing for
those psychologists that need to estimate thresholds with a good degree of accuracy
and in a short time. Together with a description of the toolbox, the current text
provides an introduction to the threshold estimation theory and a theoretical
explanation of the maximum likelihood adaptive procedure. MLP comes with a
graphical interface and it is provided with several built-in, classic psychoacoustics
experiments ready to use at a mouse click
Relationship between the magnitude of intraocular pressure during an episode of acute elevation and retinal damage four weeks later in rats
PURPOSE: To determine relationship between the magnitude of intraocular pressure (IOP) during a fixed-duration episode of acute elevation and the loss of retinal function and structure 4 weeks later in rats. METHODS: Unilateral elevation of IOP (105 minutes) was achieved manometrically in adult Brown Norway rats (9 groups; n = 4 to 8 each, 10-100 mm Hg and sham control). Full-field ERGs were recorded simultaneously from treated and control eyes 4 weeks after IOP elevation. Scotopic ERG stimuli were white flashes (-6.04 to 2.72 log cd.s.m(-2)). Photopic ERGs were recorded (1.22 to 2.72 log cd.s.m(-2)) after 15 min of light adaptation (150 cd/m(2)). Relative amplitude (treated/control, %) of ERG components versus IOP was described with a cummulative normal function. Retinal ganglion cell (RGC) layer density was determined post mortem by histology. RESULTS: All ERG components failed to recover completely normal amplitudes by 4 weeks after the insult if IOP was 70 mmHg or greater during the episode. There was no ERG recovery at all if IOP was 100 mmHg. Outer retinal (photoreceptor) function demonstrated the least sensitivity to prior acute IOP elevation. ERG components reflecting inner retinal function were correlated with post mortem RGC layer density. CONCLUSIONS: Retinal function recovers after IOP normalization, such that it requires a level of acute IOP elevation approximately 10 mmHg higher to cause a pattern of permanent dysfunction similar to that observed during the acute event. There is a 'threshold' for permanent retinal functional loss in the rat at an IOP between 60 and 70 mmHg if sustained for 105 minutes or more
Four theorems on the psychometric function
In a 2-alternative forced-choice (2AFC) discrimination task, observers choose which of two stimuli has the higher value. The psychometric function for this task gives the probability of a correct response for a given stimulus difference, Δx. This paper proves four theorems about the psychometric function. Assuming the observer applies a transducer and adds noise, Theorem 1 derives a convenient general expression for the psychometric function. Discrimination data are often fitted with a Weibull function. Theorem 2 proves that the Weibull "slope" parameter, β, can be approximated by [Formula: see text], where [Formula: see text] is the β of the Weibull function that fits best to the cumulative noise distribution, and [Formula: see text] depends on the transducer. We derive general expressions for [Formula: see text] and [Formula: see text], from which we derive expressions for specific cases. One case that follows naturally from our general analysis is Pelli's finding that, when [Formula: see text], [Formula: see text]. We also consider two limiting cases. Theorem 3 proves that, as sensitivity improves, 2AFC performance will usually approach that for a linear transducer, whatever the actual transducer; we show that this does not apply at signal levels where the transducer gradient is zero, which explains why it does not apply to contrast detection. Theorem 4 proves that, when the exponent of a power-function transducer approaches zero, 2AFC performance approaches that of a logarithmic transducer. We show that the power-function exponents of 0.4-0.5 fitted to suprathreshold contrast discrimination data are close enough to zero for the fitted psychometric function to be practically indistinguishable from that of a log transducer. Finally, Weibull β reflects the shape of the noise distribution, and we used our results to assess the recent claim that internal noise has higher kurtosis than a Gaussian. Our analysis of β for contrast discrimination suggests that, if internal noise is stimulus-independent, it has lower kurtosis than a Gaussian
Recommended from our members
Sit still and pay attention: Using the Wii Balance-Board to detect lapses in concentration in children during psychophysical testing.
During psychophysical testing, a loss of concentration can cause observers to answer incorrectly, even when the stimulus is clearly perceptible. Such lapses limit the accuracy and speed of many psychophysical measurements. This study evaluates an automated technique for detecting lapses based on body movement (postural instability). Thirty-five children (8-11 years of age) and 34 adults performed a typical psychophysical task (orientation discrimination) while seated on a Wii Fit Balance Board: a gaming device that measures center of pressure (CoP). Incorrect responses on suprathreshold catch trials provided the "reference standard" measure of when lapses in concentration occurred. Children exhibited significantly greater variability in CoP on lapse trials, indicating that postural instability provides a feasible, real-time index of concentration. Limitations and potential applications of this method are discussed
Characteristics of dynamic processing in the visual field of patients with age-related maculopathy
Purpose To investigate the characteristics of dynamic processing in the visual field of patients with age-related maculopathy (ARM) by measuring motion sensitivity, double-pulse resolution (DPR), and critical flicker fusion. Methods Fourteen subjects with ARM (18 eyes), 14 age-matched controls (19 eyes), and 7 young controls (8 eyes) served as subjects. Motion contrast thresholds were determined by a four-alternative forced-choice (4 afc) staircase procedure with a modification by Kernbach for presenting a plaid (size=3.8 degrees) moving within a stationary spatial and temporal Gaussian envelope in one of four directions. Measurements were performed on the horizontal meridian at 10 degrees, 20 degrees, 30 degrees, 40 degrees, and 60 degrees eccentricity. DPR was defined as the minimal temporal gap detectable by the subject using a 9-fold interleaved adaptive procedure, with stimuli positioned on concentric rings at 5 degrees, 10 degrees, and 20 degrees eccentricity on the principal and oblique meridians. Critical flicker fusion thresholds (CFF) and the Lanthony D-15 color vision test were applied foveally, and the subjects were free to use their fovea or whatever retinal area they needed to use instead, due to their retinal lesions caused by ARM. All measurements were performed under photopic conditions. Results Motion contrast sensitivity in subjects with ARM was pronouncedly reduced (0.23-0.66 log units, p < 0.01), not only in the macula but in a region up to 20 degrees eccentricity. In the two control groups, motion contrast sensitivity systematically declined with retinal eccentricity (0.009-0.032 log units/degree) and with age (0.01 log units/year). Double-pulse thresholds in healthy subjects were approximately constant in the central visual field and increased outside a radius of 10 degrees (1.73 ms/degree). DPR thresholds were elevated in subjects with ARM (by 23-32 ms, p < 0.01) up to 20 degrees eccentricity, and their foveal CFFs were increased by 5.5 Hz or 14% (p < 0.01) as compared with age-matched controls. Conclusions Dynamic processing properties in subjects with ARM are severely impaired in the central visual field up to 20 degrees eccentricity, which is clearly beyond the borders of the macula
Evaluation of volumetric modulated arc therapy (VMAT) with Oncentra MasterPlan® for the treatment of head and neck cancer
Background
Several comparison studies have shown the capability of VMAT to achieve similar or better plan quality as IMRT, while reducing the treatment time. The experience of VMAT in a multi vendor environment is limited. We compared the plan quality and performance of VMAT to IMRT and we investigate the effects of varying various user-selectable parameters.
Methods
IMRT, single arc VMAT and dual arc VMAT were compared for four different head-and-neck tumors. For VMAT, the effect of varying gantry angle spacing and treatment time on the plan quality was investigated. A comparison of monitor units and treatment time was performed.
Results
IMRT and dual arc VMAT achieved a similar plan quality, while single arc could not provide an acceptable plan quality. Increasing the number of control points does not improve the plan quality. Dual arc VMAT delivery time is about 30% of IMRT delivery time.
Conclusions
Dual arc VMAT is a fast and accurate technique for the treatment of head and neck cancer. It applies similar number of MUs as IMRT, but the treatment time is strongly reduced, maintaining similar or better dose conformity to the PTV and OAR sparing
Haptic Perception of Object Curvature in Parkinson's Disease
The haptic perception of the curvature of an object is essential for adequate object manipulation and critical for our guidance of actions. This study investigated how the ability to perceive the curvature of an object is altered by Parkinson's disease (PD).Eight healthy subjects and 11 patients with mild to moderate PD had to judge, without vision, the curvature of a virtual "box" created by a robotic manipulandum. Their hands were either moved passively along a defined curved path or they actively explored the curved curvature of a virtual wall. The curvature was either concave or convex (bulging to the left or right) and was judged in two locations of the hand workspace--a left workspace location, where the curved hand path was associated with curved shoulder and elbow joint paths, and a right workspace location in which these joint paths were nearly linear. After exploring the curvature of the virtual object, subjects had to judge whether the curvature was concave or convex. Based on these data, thresholds for curvature sensitivity were established. The main findings of the study are: First, 9 out 11 PD patients (82%) showed elevated thresholds for detecting convex curvatures in at least one test condition. The respective median threshold for the PD group was increased by 343% when compared to the control group. Second, when distal hand paths became less associated with proximal joint paths (right workspace), haptic acuity was reduced substantially in both groups. Third, sensitivity to hand trajectory curvature was not improved during active exploration in either group.Our data demonstrate that PD is associated with a decreased acuity of the haptic sense, which may occur already at an early stage of the disease
Application of volumetric modulated arc therapy (VMAT) in a dual-vendor environment
Background and Purpose
The purpose of this study was to assess plan quality and treatment time achievable with the new VMAT optimization tool implemented in the treatment planning system Oncentra MasterPlan® as compared to IMRT for Elekta SynergyS® linear accelerators.
Materials and methods
VMAT was implemented on a SynergyS® linear accelerator (Elekta Ltd., Crawley, UK) with Mosaiq® record and verify system (IMPAC Medical Systems, Sunnyvale, CA) and the treatment planning system Oncentra MasterPlan® (Nucletron BV, Veenendaal, the Netherlands). VMAT planning was conducted for three typical target types of prostate cancer, hypopharynx/larynx cancer and vertebral metastases, and compared to standard IMRT with respect to plan quality, number of monitor units (MU), and treatment time.
Results
For prostate cancer and vertebral metastases single arc VMAT led to similar plan quality as compared to IMRT. For treatment of the hypopharynx/larynx cancer, a second arc was necessary to achieve sufficient plan quality. Treatment time was reduced in all cases to 35% to 43% as compared to IMRT. Times required for optimization and dose calculation, however, increased by a factor of 5.0 to 6.8.
Conclusion
Similar or improved plan quality can be achieved with VMAT as compared to IMRT at reduced treatment times but increased calculation times
The psychophysics of uneconomical choice: non-linear reward evaluation by a nectar feeder
Uneconomical choices by humans or animals that evaluate reward options challenge the expectation that decision-makers always maximize the return currency. One possible explanation for such deviations from optimality is that the ability to sense differences in physical value between available alternatives is constrained by the sensory and cognitive processes for encoding profitability. In this study, we investigated the capacity of a nectarivorous bat species (Glossophaga commissarisi) to discriminate between sugar solutions with different concentrations. We conducted a two-alternative free-choice experiment on a population of wild electronically tagged bats foraging at an array of computer-automated artificial flowers that recorded individual choices. We used a Bayesian approach to fit individual psychometric functions, relating the strength of preferring the higher concentration option to the intensity of the presented stimulus. Psychometric analysis revealed that discrimination ability increases non-linearly with respect to intensity. We combined this result with a previous psychometric analysis of volume perception. Our theoretical analysis of choice for rewards that vary in two quality dimensions revealed regions of parameter combinations where uneconomic choice is expected. Discrimination ability may be constrained by non-linear perceptual and cognitive encoding processes that result in uneconomical choice
Accurate and Rapid Estimation of Phosphene Thresholds (REPT)
To calibrate the intensity of transcranial magnetic stimulation (TMS) at the occipital pole, the phosphene threshold is used as a measure of cortical excitability. The phosphene threshold (PT) refers to the intensity of magnetic stimulation that induces illusory flashes of light (phosphenes) on a proportion of trials. The existing PT estimation procedures lack the accuracy and mathematical rigour of modern threshold estimation methods. We present an improved and automatic procedure for estimating the PT which is based on the well-established Ψ Bayesian adaptive staircase approach. To validate the new procedure, we compared it with another commonly used procedure for estimating the PT. We found that our procedure is more accurate, reliable, and rapid when compared with an existing PT measurement procedure. The new procedure is implemented in Matlab and works automatically with the Magstim Rapid2 stimulator using a convenient graphical user interface. The Matlab program is freely available for download
- …
