4,416 research outputs found
Measurement of the eta mass at KLOE
An integrated luminosity of 410 pb^(-1), corresponding to ~ 17 million of eta
events, has been analyzed to measure the eta mass using the decay eta to gamma
gamma. The measurement is insensitive to the calorimeter energy calibration and
the systematic error on the measurement is dominated by the uniformity of the
detector response. As a cross check of the method the pi0 mass from the decay
phi to pi0 gamma, pi0 to gamma gamma has been measured and it is in agreement
with the most accurate previous determinations. The result obtained is m(eta) =
547.873 +/- 0.007 (stat.) +/- 0.031 (syst.) MeV, that is today best measurement
of the eta mass.Comment: 7 pages, 8 figures, Contributed paper to Lepton Photon 200
Measurement of the neutron detection efficiency of a 80% absorber - 20% scintillating fibers calorimeter
The neutron detection efficiency of a sampling calorimeter made of 1 mm
diameter scintillating fibers embedded in a lead/bismuth structure has been
measured at the neutron beam of the The Svedberg Laboratory at Uppsala. A
significant enhancement of the detection efficiency with respect to a bulk
organic scintillator detector with the same thickness is observed.Comment: 10 pages, 7 figure
An inhibitor of HIV-1 protease modulates constitutive eIF2α dephosphorylation to trigger a specific integrated stress response.
Inhibitors of the HIV aspartyl protease [HIV protease inhibitors (HIV-PIs)] are the cornerstone of treatment for HIV. Beyond their well-defined antiretroviral activity, these drugs have additional effects that modulate cell viability and homeostasis. However, little is known about the virus-independent pathways engaged by these molecules. Here we show that the HIV-PI Nelfinavir decreases translation rates and promotes a transcriptional program characteristic of the integrated stress response (ISR). Mice treated with Nelfinavir display hallmarks of this stress response in the liver, including α subunit of translation initiation factor 2 (eIF2α) phosphorylation, activating transcription factor-4 (ATF4) induction, and increased expression of known downstream targets. Mechanistically, Nelfinavir-mediated ISR bypassed direct activation of the eIF2α stress kinases and instead relied on the inhibition of the constitutive eIF2α dephosphorylation and down-regulation of the phophatase cofactor CReP (Constitutive Repressor of eIF2α Phosphorylation; also known as PPP1R15B). These findings demonstrate that the modulation of eIF2α-specific phosphatase cofactor activity can be a rheostat of cellular homeostasis that initiates a functional ISR and suggest that the HIV-PIs could be repositioned as therapeutics in human diseases to modulate translation rates and stress responses
A global fit to determine the pseudoscalar mixing angle and the gluonium content of the eta' meson
We update the values of the eta-eta' mixing angle and of the eta' gluonium
content by fitting our measurement R_phi = BR(phi to eta' gamma)/ BR(phi to eta
gamma) together with several vector meson radiative decays to pseudoscalars (V
to P gamma), pseudoscalar mesons radiative decays to vectors (P to V gamma) and
the eta' to gamma gamma, pi^0 to gamma gamma widths. From the fit we extract a
gluonium fraction of Z^2_G = 0.12 +- 0.04, the pseudoscalar mixing angle psi_P
= (40.4 +- 0.6) degree and the phi-omega mixing angle psi_V = (3.32 +- 0.09)
degree. Z^2_G and psi_P are fairly consistent with those previously published.
We also evaluate the impact on the eta' gluonium content determination of
future experimental improvements of the eta' branching ratios and decay width.Comment: 13 pages, 7 figures to submit to JHE
Boost operators in Coulomb-gauge QCD: the pion form factor and Fock expansions in phi radiative decays
In this article we rederive the Boost operators in Coulomb-Gauge Yang-Mills
theory employing the path-integral formalism and write down the complete
operators for QCD. We immediately apply them to note that what are usually
called the pion square, quartic... charge radii, defined from derivatives of
the pion form factor at zero squared momentum transfer, are completely blurred
out by relativistic and interaction corrections, so that it is not clear at all
how to interpret these quantities in terms of the pion charge distribution. The
form factor therefore measures matrix elements of powers of the QCD boost and
Moeller operators, weighted by the charge density in the target's rest frame.
In addition we remark that the decomposition of the eta' wavefunction in
quarkonium, gluonium, ... components attempted by the KLOE collaboration
combining data from phi radiative decays, requires corrections due to the
velocity of the final state meson recoiling against a photon. This will be
especially important if such decompositions are to be attempted with data from
J/psi decays.Comment: 14 pages, 4 figure
Determination of the total width of the eta' meson
Taking advantage of both the low-emittance proton-beam of the Cooler
Synchrotron COSY and the high momentum precision of the COSY-11 detector
system, the mass distribution of the eta' meson was measured with a resolution
of 0.33 MeV/c^2 (FWHM), improving the experimental mass resolution by almost an
order of magnitude with respect to previous results. Based on the sample of
more than 2300 reconstructed pp --> pp eta' events the total width of the eta'
meson was determined to be 0.226 +- 0.017(stat.) +- 0.014(syst.) MeV/c^2.Comment: 4 pages, 4 figure
Measurement of neutron detection efficiency between 22 and 174 MeV using two different kinds of Pb-scintillating fiber sampling calorimeters
We exposed a prototype of the lead-scintillating fiber KLOE calorimeter to
neutron beam of 21, 46 and 174 MeV at The Svedberg Laboratory, Uppsala, to
study its neutron detection efficiency. This has been found larger than what
expected considering the scintillator thickness of the prototype. %To check our
method, we measured also the neutron %detection efficiency of a 5 cm thick
NE110 scintillator. We show preliminary measurement carried out with a
different prototype with a larger lead/fiber ratio, which proves the relevance
of passive material to neutron detection efficiency in this kind of
calorimeters
Future circular collider studies
With the end of the High-Luminosity LHC (HL-LHC) run, the
physics potential of pp colliders at an energy of about 14 TeV will be completely exploited. Nevertheless important fundamental questions about the Standard Model, in case of missing evidences of new physics, still would need to be addressed. One possible option to continue the investiagtion of fundamental physics is the building up of higher-energy e+e− and pp machines. The physics potential and motivations
of such machines will be summarised in this contribution
- …
