14 research outputs found

    Paralel kesintisiz güç kaynaklarından oluşan dağınık güç sistemlerinde aktif yük paylaşımı

    Get PDF
    Continuity of power flow is very important for telecommunication systems, hospitals, computers and critical industrial facilities. Uninterrupted Power Supplies (UPS) have been in use for several years for this purpose. Increased power requirement of these systems has led to operation of several UPS units in parallel. However, this has brought in issues related to the control of these systems. Initially, parallel systems composed of equally rated units were built. The controllers of these systems compared the current drawn by each unit to the average current levels to minimize the error. Equal rated unit selection requirement poses an important limitation for these systems. Later on, a communication line that carries the current and frequency information was used for control purposes. The most important disadvantage of these systems is that the communication lines are open to noise and any noise related problem may affect the whole system. Also, the system becomes more complicated due to the use of communication line. This study investigates the use of power-frequency droop method, which has been used in power systems for a long time, in parallel connected, distributed power systems. Each USP unit is supposed to have its own controller. These controllers operate only on its own output current and voltage data. As there is no communication line in this system, the operation is simpler and thus, more reliable. Controllers compute the active power by using the current and voltage values, and then adjust the frequency based on the power-frequency droop characteristic. Each unit has its own power-frequency characteristic. That means the system may consist of units with different rated power levels. When the load of the system changes each unit responds immediately and contributes in proportion with their rated power levels. This enables each unit to operate at their optimum operating level. It is obvious that this method causes the frequency to deviate from the rated value. The frequency of the system can be restored to the original value by shifting the power-frequency characteristic vertically. In this work, a distributed power system consisting of two parallel UPS units is investigated. The system can be loaded at two different points. Focus of the operation is on the inverter parts. Each inverter uses Sinusoidal PWM (SPWM) method, and has an LC filter at their outputs. Inverter outputs are connected together by a tie-line inductor. This line is required to transfer power from one unit to a load located near the other unit. PWM signals of each inverter are generated by using the frequency that is determined after using the power-frequency droop method. Since each unit has a different power-frequency droop characteristic and different power rating, they also have a different PWM frequency. This leads to a phase difference between the output voltages, and to a power flow through the tie-line. After a transient period following a load change, each unit shares the load power in proportion with their rated power values. First of all a system simulation was done by using Matlab-SIMULINK. Then, the simulation results were confirmed by an experimental set-up including a DS-1103 DSP controller and two ASIPM modules. One of the inverters was chosen to be 50% higher rated to experience transient frequency deviations when the load changes. As expected, different frequency values were observed following load changes. This led to a phase difference between the units, and thus power flow through tie-line. The frequencies are equalized at the steady state, and the phase difference is fixed. Frequency restoration algorithm then takes over, and brings the frequencies back to the rated level. The two load units used in the system are equal, but the inverters supply these loads in proportion with their power ratings, meaning that one supplies 50% more power than the other one. Simulation and experimental results are in agreement. Power-frequency droop algorithm yields the synchronous operation of two units in parallel, at a higher power level. As the individual units operate near their rated power levels the efficiency is increased. Due to the lack of communication line, the control is simpler and the operation is more reliable. Parallel operation also adds redundancy to the system.  Keywords: Parallel operated UPS systems, distributed power systems, load sharing, mircogrid.Bu çalışmada, iki adet üç fazlı kesintisiz güç kaynağından (KGK) oluşan bir dağınık güç sisteminde aktif güç paylaşımı incelenmektedir. Çalışmada KGK sistemlerinin, çıkış katındaki eviricileri üzerinde durulduğundan, sistemin iki adet paralel eviriciden oluştuğu varsayılmıştır. Bu çalışmada enterkonnekte güç sistemlerinde yıllardır kullanılmakta olan yük-frekans düşüm yönteminin paralel çalışan KGK birimlerine uyarlanabildiği gösterilmiştir. Bu yöntemde her bir KGK birimi kendi denetleyicisine sahiptir ve sadece denetlediği birimin çıkış akım ve gerilim bilgilerini kullanmaktadır. Bu sayede herhangi bir haberleşme hattının kullanılmasına gerek kalmamaktadır. Denetleyiciler, birimlerden aldığı akım ve gerilim bilgilerinden aktif gücü hesaplayarak, yük-frekans düşüm karakteristiğine göre belirlenen yeni frekansı, ayar değeri olarak kullanır. Her bir birimin kendine ait bir yük-frekans düşüm karakteristiği olduğundan, sistemde farklı nominal güç değerlerine sahip KGK birimleri kullanılabilir. Sistemdeki toplam yük değişimine her bir birim anında tepki vererek, değişim miktarını kendi güçleri oranında karşılar. Böylece farklı güçlerdeki birimlerin her biri optimal bir güç seviyesinde çalışır. Her bir eviriciye ait olan kontrol algoritması, düşüm karakteristiğini kullanarak, eviricilerin güçleri oranına ve sistemde bulunan yüklerin değerine göre eviricilerin frekanslarını, tespit eder. Bu frekanslar, çıkış gerilimleri arasında faz farkına yola açar ve eviricilerin sisteme verecekleri güç ve ara bağlantı hattından akacak güç akışı sağlanmış olur. Sonuçta paralel çalışma ve sistemin toplam yükünün eviricilerin güçleri oranında paylaşılması gerçekleşmiş olur. Sistemin benzetimi Matlab-Simulink paket programında yapılmıştır. Deneysel çalışmada ise ASIPM evirici modülleri ve denetleyici kart olarak da DS-1103 kullanılmıştır. Anahtar Kelimeler: Paralel çalışan KGK sistemleri, dağınık güç sistemleri, yük paylaşımı, mikro şebeke.&nbsp

    Burn Rehabilitation

    No full text
    Burn injuries are important in terms of causing serious disability and threatening life. With the establishment of modern burn treatment units and advances in acute care management contributed to a reduced mortality rate over the last decades. As a result of improved outcome, more attention has to be given to a comprehensive burn rehabilitation program. Burn rehabilitation is a process that starts from day of admission and continues for months or sometimes years after the initial event. The term ‘burn rehabilitation’ incorporates the physical, physiological and social aspects of care. Burns can leave a patient with severely debilitating and deforming contractures, which can lead to significant disability when left untreated. Burn rehabilitation aims to prevent the possible complications, minimalize joint contractures and deformities, increase range of motion, control hypertrophic scarring, achieve the best possible functional capacity and to regain the patients vocational and recreational activities. (Journal of the Turkish Society Intensive Care 2011; 9 Suppl: 70-7

    Preliminary Report on the 2021 Fieldwork at Phoenix

    No full text
    Situé dans la partie sud-ouest de la péninsule de Bozburun (Marmaris), le site an- tique de Phoenix a fait l'objet d'une première campagne de prospection archéologique multidisciplinaire durant le mois de septembre 2021. Les travaux sur le terrain avaient pour objectif de mieux connaître l'espace urbain du site en général, ainsi que certaines structures en particulier, comme le temple d'Apollon transformé en église, l'acropole et les nécropoles parsemées de nombreuses terrasses. Parallèlement à nos recherches purement archéologiques, nous avons pu mettre en œuvre un programme d'éducation sur le patrimoine culturel et écologique pour les enfants vivant dans la région. Nous avons également lancé un programme pour documenter l'architecture rurale de la région et nous avons mené des entretiens d'histoire orale avec les personnes âgées du village de Taşlıca.Located in the southwestern part of the Bozburun Peninsula (Marmaris), the ancient site of Phoenix was the subject of a first multidisciplinary archaeological survey campaign in September 2021. The fieldwork aimed to better understand the town planning of the site in general, as well as certain structures in particular such as the temple of Apollo converted into a church, the acropolis, and the necropoleis dotted with numerous terraces. In addition to purely archaeological research, we also carried out a cultural and ecological heritage edu- cation program for children who live in the region. We also started a program to document the area’s rural architecture and conducted oral history interviews with the elderly people of Taşlıca village

    Çocuk onkoloji hastalarında ve kardeşlerinde ekran ve internet bağımlılığının değerlendirilmesi

    No full text
    Giriş: Gerek hızlı gelişen teknoloji gerekse COVİD-19 pandemisi insanları internet ile daha çok vakit geçirmeye itmiştir. İnternet ve ekranbağımlılığında en büyük risk grubu çocuklar ve ergenlerdir. Herşeyin aşırıya kaçımında sorunlar doğduğu gibi internetin aşırı kullanımında da fiziksel ve psikolojik sorunlar ortaya çıkmaktadır. Bu çalışmanın amacı, DEÜ Onkoloji Enstitüsü Çocuk Onkolojisi Bilim Dalındatedavi gören çocukların ve kardeşlerinin internet ve ekran bağımlılığını değerlendirmektir.Yöntem: Bu çalışmada, hastalarımızın, gerek hastanede yatarken gerekse evde oldukları dönemde televizyon, tablet ve telefon ile nekadar süre ilgilendikleri, hangi içerikleri tercih ettiklerinin değerlendirilmesi hedeflenmiştir. Bu amaçla tarafımızca hazırlanan 128 soruluk bir anket ebeveynlere, hasta çocuğa ve kardeşe uygulanmıştır. Anket verileri Excel dosyasına kaydedilmiş ve tanımlayıcı istatistikselanalizler yapılmıştır.Bulgular: Hastalarımızın 53’ü kız, 47’si erkekti. Ortanca tanı yaşı 3 yaş (0–17) idi. Ebeveynlerin %89’u evli, %11’i boşanmış idi. Evlerin %89’undainternet vardı. Yüz çocuk onkoloji hastası ve 66 sağlıklı kardeş üzerinde yaptığımız anket çalışması sonucunda her iki grupta elektronik cihazve ekran ile temas oranının çok yüksek olduğunu (Tablo1) ve çok küçük yaşta elektronik cihazlarla temas etmeye başladıklarını gördük. Kitapokuma, resim yapma, müzik enstrumanı çalma, el işi ile ilgilenme oranlarını elektronik cihaz kullanım oranlarına göre daha düşük bulduk(Tablo2). Elektronik cihazları ve interneti erken yaşta ve uzun süreli kullanmak ile ilişkili olabilecek şekilde çocukların uyku saatlerinin çokgeç olduğunu ve dikkat eksikliğinin her iki grupta %20 üzerinde olduğunu, gözlük kullanma sıklığının yine %20 civarında olduğunu gördük.Yorum: Gerek çocuk onkoloji hastalarında gerekse sağlıklı kardeşlerinde ekran ve internet kullanımını objektif olarak saptamış ve dökümante etmiş olduk. Bu çalışmanın devamı olarak çocukları internet ve ekrandan uzak tutmaya veya sınırlı maruziyeti sağlamaya yönelikebeveynleri bilgilendirici broşürler hazırlanabileceği; ekran ve internet bağımlılıklarını azaltmak üzere çocuklarla kitap okuma, resimveya el işi yapma, kutu oyunu oynama, müzik dinletisi, tiyatro gibi etkinliklerin sosyal sorumluluk projeleri olarak planlanmasının yararsağlayacağı görüşündeyiz.Anahtar Kelimeler:&nbsp;Ekran ve internet bağımlığı, anket, çocuk onkoloji</p

    Clinical outcomes and independent risk factors for 90-day mortality in critically ill patients with respiratory failure infected with sars-cov-2: A multicenter study in turkish intensive care units

    Get PDF
    Background: There are limited data on the long-term outcomes of COVID-19 from different parts of the world. Aims: To determine risk factors of 90-day mortality in critically ill patients in Turkish intensive care units (ICUs), with respiratory failure. Study design: Retrospective, observational cohort. Methods: Patients with laboratory-confirmed COVID-19 and who had been followed up in the ICUs with respiratory failure for more than 24 hours were included in the study. Their demographics, clinical characteristics, laboratory variables, treatment protocols, and survival data were recorded. Results: A total of 421 patients were included. The median age was 67 (IQR: 57-76) years, and 251 patients (59.6%) were men. The 90-day mortality rate was 55.1%. The factors independently associated with 90-day mortality were invasive mechanical ventilation (IMV) (HR 4.09 [95% CI: [2.20-7.63], P 2 mmol/L (2.78 [1.93-4.01], P < .001), age ≥60 years (2.45 [1.48-4.06)], P < .001), cardiac arrhythmia during ICU stay (2.01 [1.27-3.20], P = .003), vasopressor treatment (1.94 [1.32-2.84], P = .001), positive fluid balance of ≥600 mL/day (1.68 [1.21-2.34], P = .002), PaO2 /FiO2 ratio of ≤150 mmHg (1.66 [1.18-2.32], P = .003), and ECOG score ≥1 (1.42 [1.00-2.02], P = .050). Conclusion: Long-term mortality was high in critically ill patients with COVID-19 hospitalized in intensive care units in Turkey. Invasive mechanical ventilation, lactate level, age, cardiac arrhythmia, vasopressor therapy, positive fluid balance, severe hypoxemia and ECOG score were the independent risk factors for 90-day mortality. Copyright@Author(s)
    corecore