Vibration isolation and pressure compensation apparatus for sensitive instrumentation
A system for attenuating the inherent vibration associated with a mechanical refrigeration unit employed to cryogenically cool sensitive instruments used in measuring chemical constituents of the atmosphere is described. A modular system including an instrument housing and a reaction bracket with a refrigerator unit floated there between comprise the instrumentation system. A pair of evacuated bellows that "float' refrigerator unit and provide pressure compensation at all levels of pressure from seal level to the vacuum of space. Vibration isolators and when needed provide additional vibration damping for the refrigerator unit. A flexible thermal strap (20 K) serves to provide essentially vibration free thermal contact between cold tip of the refrigerator unit and the instrument component mounted on the IDL mount. Another flexible strap (77 K) serves to provide vibration free thermal contact between the TDL mount thermal shroud and a thermal shroud disposed about the thermal shaft
Thermoelectric temperature control system for the pushbroom microwave radiometer (PBMR)
A closed loop thermoelectric temperature control system is developed for stabilizing sensitive RF integrated circuits within a microwave radiometer to an accuracy of + or - 0.1 C over a range of ambient conditions from -20 C to +45 C. The dual mode (heating and cooling) control concept utilizes partial thermal isolation of the RF units from an instrument deck which is thermally controlled by thermoelectric coolers and thin film heaters. The temperature control concept is simulated with a thermal analyzer program (MITAS) which consists of 37 nodes and 61 conductors. A full scale thermal mockup is tested in the laboratory at temperatures of 0 C, 21 C, and 45 C to confirm the validity of the control concept. A flight radiometer and temperature control system is successfully flight tested on the NASA Skyvan aircraft
Development of a high-altitude airborne dial system: The Lidar Atmospheric Sensing Experiment (LASE)
The ability of a Differential Absorption Lidar (DIAL) system to measure vertical profiles of H2O in the lower atmosphere was demonstrated both in ground-based and airborne experiments. In these experiments, tunable lasers were used that required real-time experimenter control to locate and lock onto the atmospheric H2O absorption line for the DIAL measurements. The Lidar Atmospheric Sensing Experiment (LASE) is the first step in a long-range effort to develop and demonstrate an autonomous DIAL system for airborne and spaceborne flight experiments. The LASE instrument is being developed to measure H2O, aerosol, and cloud profiles from a high-altitude ER-2 (extended range U-2) aircraft. The science of the LASE program, the LASE system design, and the expected measurement capability of the system are discussed
Criminal narrative experience: relating emotions to offence narrative roles during crime commission
A neglected area of research within criminality has been that of the experience of the offence for the offender. The present study investigates the emotions and narrative roles that are experienced by an offender while committing a broad range of crimes and proposes a model of Criminal Narrative Experience (CNE). Hypotheses were derived from the Circumplex of Emotions (Russell, 1997), Frye (1957), Narrative Theory (McAdams, 1988) and its link with Investigative Psychology (Canter, 1994). The analysis was based on 120 cases. Convicted for a variety of crimes, incarcerated criminals were interviewed and the data were subjected to Smallest Space Analysis (SSA). Four themes of Criminal Narrative Experience (CNE) were identified: Elated Hero, Calm Professional, Distressed Revenger and Depressed Victim in line with the recent theoretical framework posited for Narrative Offence Roles (Youngs & Canter, 2012). The theoretical implications for understanding crime on the basis of the Criminal Narrative Experience (CNE) as well as practical implications are discussed
Recommended from our members
Performance-based building and innovation: Balancing client and industry needs
One reason for the interest in performance-based building is that it is commonly advocated as a powerful way of enhancing innovation performance by articulating building performance outcomes, and by offering relevant procurement actors the discretion to innovate to meet these performance requirements more effectively and/or efficiently. The paper argues that the current approach to performance-based building assumes that relevant actors have the capacity, ability and motivation to innovate from a business perspective. It is proposed that the prevailing conceptualization of PBB is too restrictive and should be broadened explicitly to accommodate the required business logic that must be in place before actors will innovate. The relevant performance-based building and innovation literature is synthesized to support the assertion. The paper concludes with an innovation-focused definition of performance-based building
Electron paramagnetic resonance and other properties of hydrogenases isolated from Desulfovibrio vulgaris (strain Hildenborough) and Megasphaera elsdenii
Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/65872/1/j.1432-1033.1983.tb07727.x.pd
Healthcare designers’ use of prescriptive and performance-based approaches
In the UK, healthcare built environment design is guided by a series of long-established design standards and guidance issued by the Department of Health. More recently, healthcare design focus has broadened to encompass new approaches, supported by large bodies of credible research evidence. It is therefore timely to rethink how healthcare design standards and guidance should be best expressed to suit ‘designerly ways’ of using evidence, to improve their use and effectiveness in practice. This research explored how designers use performance and prescriptive approaches during the healthcare design process. Three in-depth healthcare built environment case studies were used to explore how designers employed such approaches during the design of selected exemplar design elements. Results show that design elements in the pre and conceptual design phases significantly employed performance-based approaches, and due to project-unique circumstances, prescriptive solutions were often significantly modified based on performance criteria. For design elements in the detailed and technical design phases, there was a significant use of solutions based on prescriptive approaches, whilst performance-based criteria were used to evaluate design solutions. This research proposes a performance-based, specification-driven healthcare design with supplementary prescriptive specifications provided for optimum healthcare environment design
Three-dimensional random Voronoi tessellations: From cubic crystal lattices to Poisson point processes
We perturb the SC, BCC, and FCC crystal structures with a spatial Gaussian noise whose adimensional strength is controlled by the parameter a, and analyze the topological and metrical properties of the resulting Voronoi Tessellations (VT). The topological properties of the VT of the SC and FCC crystals are unstable with respect to the introduction of noise, because the corresponding polyhedra are geometrically degenerate, whereas the tessellation of the BCC crystal is topologically stable even against noise of small but finite intensity. For weak noise, the mean area of the perturbed BCC and FCC crystals VT increases quadratically with a. In the case of perturbed SCC crystals, there is an optimal amount of noise that minimizes the mean area of the cells. Already for a moderate noise (a>0.5), the properties of the three perturbed VT are indistinguishable, and for intense noise (a>2), results converge to the Poisson-VT limit. Notably, 2-parameter gamma distributions are an excellent model for the empirical of of all considered properties. The VT of the perturbed BCC and FCC structures are local maxima for the isoperimetric quotient, which measures the degre of sphericity of the cells, among space filling VT. In the BCC case, this suggests a weaker form of the recentluy disproved Kelvin conjecture. Due to the fluctuations of the shape of the cells, anomalous scalings with exponents >3/2 is observed between the area and the volumes of the cells, and, except for the FCC case, also for a->0. In the Poisson-VT limit, the exponent is about 1.67. As the number of faces is positively correlated with the sphericity of the cells, the anomalous scaling is heavily reduced when we perform powerlaw fits separately on cells with a specific number of faces
Shadowing in Inelastic Scattering of Muons on Carbon, Calcium and Lead at Low XBj
Nuclear shadowing is observed in the per-nucleon cross-sections of positive
muons on carbon, calcium and lead as compared to deuterium. The data were taken
by Fermilab experiment E665 using inelastically scattered muons of mean
incident momentum 470 GeV/c. Cross-section ratios are presented in the
kinematic region 0.0001 < XBj <0.56 and 0.1 < Q**2 < 80 GeVc. The data are
consistent with no significant nu or Q**2 dependence at fixed XBj. As XBj
decreases, the size of the shadowing effect, as well as its A dependence, are
found to approach the corresponding measurements in photoproduction.Comment: 22 pages, incl. 6 figures, to be published in Z. Phys.
- …