774 research outputs found

    Body mass index, abdominal fatness, fat mass and the risk of atrial fibrillation: a systematic review and dose–response meta-analysis of prospective studies

    Get PDF
    Different adiposity measures have been associ- ated with increased risk of atrial fibrillation, however, results have previously only been summarized for BMI. We therefore conducted a systematic review and meta- analysis of prospective studies to clarify the association between different adiposity measures and risk of atrial fibrillation. PubMed and Embase databases were searched up to October 24th 2016. Summary relative risks (RRs) were calculated using random effects models. Twenty-nine unique prospective studies (32 publications) were included. Twenty-five studies (83,006 cases, 2,405,381 participants) were included in the analysis of BMI and atrial fibrillation. The summary RR was 1.28 (95% confidence interval: 1.20–1.38, I 2 = 97%) per 5 unit increment in BMI, 1.18 (95% CI: 1.12–1.25, I 2 = 73%, n = 5) and 1.32 (95% CI: 1.16–1.51, I 2 = 91%, n = 3) per 10 cm increase in waist and hip circumference, respectively, 1.09 (95% CI: 1.02–1.16, I 2 = 44%, n = 4) per 0.1 unit increase in waist- to-hip ratio, 1.09 (95% CI: 1.02–1.16, I 2 = 94%, n = 4) per 5 kg increase in fat mass, 1.10 (95% CI: 0.92–1.33, I 2 = 90%, n = 3) per 10% increase in fat percentage, 1.10 (95% CI: 1.08–1.13, I 2 = 74%, n = 10) per 5 kg increase in weight, and 1.08 (95% CI: 0.97–1.19, I 2 = 86%, n = 2) per 5% increase in weight gain. The association between BMI and atrial fibrillation was non- linear, p nonlinearity \ 0.0001, with a stronger association at higher BMI levels, however, increased risk was observed even at a BMI of 22–24 compared to 20. In conclusion, general and abdominal adiposity and higher body fat mass increase the risk of atrial fibrillation

    Performance of the Micromegas detector in the CAST experiment

    Full text link
    The gaseous Micromegas detector designed for the CERN Axion search experiment CAST, operated smoothly during Phase-I, which included the 2003 and 2004 running periods. It exhibited linear response in the energy range of interest (1-10keV), good spatial sensitivity and energy resolution (15-19% FWHM at 5.9keV)as well as remarkable stability. The detector's upgrade for the 2004 run, supported by the development of advanced offline analysis tools, improved the background rejection capability, leading to an average rate 5x10^-5 counts/sec/cm^2/keV with 94% cut efficiency. Also, the origin of the detected background was studied with a Monte Carlo simulation, using the GEANT4 package.Comment: Prepared for PSD7: The Seventh International Conference on Position Sensitive Detectors, Liverpool, United Kingdom, 12-16 Sep. 200

    Neutrophil to lymphocyte ratio and cancer prognosis: an umbrella review of systematic reviews and meta-analyses of observational studies

    Get PDF
    Background Although neutrophils have been linked to the progression of cancer, uncertainty exists around their association with cancer outcomes, depending on the site, outcome and treatments considered. We aimed to evaluate the strength and validity of evidence on the association between either the neutrophil to lymphocyte ratio (NLR) or tumour-associated neutrophils (TAN) and cancer prognosis. Methods We searched MEDLINE, Embase and Cochrane Database of Systematic Reviews from inception to 29 May 2020 for systematic reviews and meta-analyses of observational studies on neutrophil counts (here NLR or TAN) and specific cancer outcomes related to disease progression or survival. The available evidence was graded as strong, highly suggestive, suggestive, weak or uncertain through the application of pre-set GRADE criteria. Results A total of 204 meta-analyses from 86 studies investigating the association between either NLR or TAN and cancer outcomes met the criteria for inclusion. All but one meta-analyses found a hazard ratio (HR) which increased risk (HR > 1). We did not find sufficient meta-analyses to evaluate TAN and cancer outcomes (N = 9). When assessed for magnitude of effect, significance and bias related to heterogeneity and small study effects, 18 (9%) associations between NLR and outcomes in composite cancer endpoints (combined analysis), cancers treated with immunotherapy and some site specific cancers (urinary, nasopharyngeal, gastric, breast, endometrial, soft tissue sarcoma and hepatocellular cancers) were supported by strong evidence. Conclusion In total, 60 (29%) meta-analyses presented strong or highly suggestive evidence. Although the NLR and TAN hold clinical promise in their association with poor cancer prognosis, further research is required to provide robust evidence, assess causality and test clinical utility

    Progress on a spherical TPC for low energy neutrino detection

    Full text link
    The new concept of the spherical TPC aims at relatively large target masses with low threshold and background, keeping an extremely simple and robust operation. Such a device would open the way to detect the neutrino-nucleus interaction, which, although a standard process, remains undetected due to the low energy of the neutrino-induced nuclear recoils. The progress in the development of the fist 1 m3^3 prototype at Saclay is presented. Other physics goals of such a device could include supernova detection, low energy neutrino oscillations and study of non-standard properties of the neutrino, among others.Comment: 3 pages, talk given at the 9th Workshop on Topics in Astroparticle and Underground Physics, Zaragoza, September 10-1

    Blood pressure, hypertension and the risk of atrial fibrillation: a systematic review and meta-analysis of cohort studies

    Get PDF
    Elevated blood pressure and hypertension have been associated with increased risk of atrial fibrillation in a number of epidemiological studies, however, the strength of the association has differed between studies. We conducted a systematic review and meta-analysis of the association between blood pressure and hypertension and atrial fibrillation. PubMed and Embase databases were searched for studies of hypertension and blood pressure and atrial fibrillation up to June 6th 2022. Cohort studies reporting adjusted relative risk (RR) estimates and 95% confidence intervals (CIs) of atrial fibrillation associated with hypertension or blood pressure were included. A random effects model was used to estimate summary RRs. Sixty eight cohort studies were included in the meta-analysis. The summary RR was 1.50 (95% CI: 1.42-1.58, I2 = 98.1%, n = 56 studies) for people with hypertension compared to those without hypertension (1,080,611 cases, 30,539,230 participants), 1.18 (95% CI: 1.16-1.21, I2 = 65.9%, n = 37 studies) per 20 mmHg increase in systolic blood pressure (346,471 cases, 14,569,396 participants), and 1.07 (95% CI: 1.03-1.11, I2 = 91.5%, n = 22 studies) per 10 mmHg increase in diastolic blood pressure (332,867 cases, 14,354,980 participants). There was evidence of a nonlinear association between diastolic blood pressure and atrial fibrillation with a steeper increase in risk at lower levels of diastolic blood pressure, but for systolic blood pressure the association appeared to be linear. For both systolic and diastolic blood pressure, the risk increased even within the normal range of blood pressure and persons at the high end of systolic and diastolic blood pressure around 180/110 mmHg had a 1.8-2.3 fold higher risk of atrial fibrillation compared to those with a blood pressure of 90/60 mmHg. These results suggest that elevated blood pressure and hypertension increases the risk of atrial fibrillation and there is some increase in risk even within the normal range of systolic and diastolic blood pressure

    Lowering the background level and the energy threshold of Micromegas x-ray detectors for axion searches

    Full text link
    Axion helioscopes search for solar axions by their conversion in x-rays in the presence of high magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. In this work, we review the recent advances on Micromegas detectors used in the CERN Axion Solar Telescope (CAST) and proposed for the future International Axion Observatory (IAXO). The actual setup in CAST has achieved background levels below 10−6^{-6} keV−1^{-1} cm−2^{-2} s−1^{-1}, a factor 100 lower than the first generation of Micromegas detectors. This reduction is based on active and passive shielding techniques, the selection of radiopure materials, offline discrimination techniques and the high granularity of the readout. We describe in detail the background model of the detector, based on its operation at CAST site and at the Canfranc Underground Laboratory (LSC), as well as on Geant4 simulations. The best levels currently achieved at LSC are low than 10−7^{-7} keV−1^{-1} cm−2^{-2} s−1^{-1} and show good prospects for the application of this technology in IAXO. Finally, we present some ideas and results for reducing the energy threshold of these detectors below 1 keV, using high-transparent windows, autotrigger electronics and studying the cluster shape at different energies. As a high flux of axion-like-particles is expected in this energy range, a sub-keV threshold detector could enlarge the physics case of axion helioscopes.Comment: Proceedings of 3rd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2014

    Micromegas in a Bulk

    Full text link
    In this paper we present a novel way to manufacture the bulk Micromegas detector. A simple process based on the PCB (Printed Circuit Board) technology is employed to produce the entire sensitive detector. Such fabrication process could be extended to very large area detectors made by the industry. The low cost fabrication together with the robustness of the electrode materials will make it extremely attractive for several applications ranging from particle physics and astrophysics to medicineComment: 6 pages, 4 figure

    Characterization of microbulk detectors in argon- and neon-based mixtures

    Full text link
    A recent Micromegas manufacturing technique, so called Microbulk, has been developed, improving the uniformity and stability of this kind of detectors. Excellent energy resolutions have been obtained, reaching values as low as 11% FWHM at 5.9 keV in Ar+5%iC4H10. This detector has other advantages like its flexible structure, low material budget and high radio-purity. Two microbulk detectors with gaps of 50 and 25 um have been characterized in argon- and neon-based mixtures with ethane, isobutane and cyclohexane. The results will be presented and discussed. The gain curves have been fitted to the Rose-Korff gain model and dependences of the electron mean free path and the threshold energy for ionization have been obtained. The possible relation between these two parameters and the energy resolution will be also discussed.Comment: Submitted to the Journal of Instrumentatio

    CAST microbulk micromegas in the Canfranc Underground Laboratory

    Get PDF
    During the last taking data campaigns of the CAST experiment, the micromegas detectors have achieved background levels of ≈5×10−6\approx 5 \times 10^{-6}keV−1^{-1}cm−2^{-2}s−1^{-1} between 2 and 9 keV. This performance has been possible thanks to the introduction of the microbulk technology, the implementation of a shielding and the development of discrimination algorithms. It has motivated new studies towards a deeper understanding of CAST detectors background. One of the working lines includes the construction of a replica of the set-up used in CAST by micromegas detectors and its installation in the Canfranc Underground Laboratory. Thanks to the comparison between the performance of the detectors underground and at surface, shielding upgrades, etc, different contributions to the detectors background have been evaluated. In particular, an upper limit <2×10−7< 2 \times 10^{-7}keV−1^{-1}cm−2^{-2}s−1^{-1} for the intrinsic background of the detector has been obtained. This work means a first evaluation of the potential of the newest micromegas technology in an underground laboratory, the most suitable environment for Rare Event Searches.Comment: 6 pages, 8 figures. To appear in the proceedings of the 2nd International Conference on Technology and Instrumentation for Particle Physics (TIPP 2011

    A low background Micromegas detector for the CAST experiment

    Full text link
    A low background Micromegas detector has been operating on the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector operated efficiently and achieved a very low level of background rejection (5×10−55\times 10^{-5} counts keV−1^{-1}cm−2^{-2}s−1^{-1}) thanks to its good spatial and energy resolution as well as the low radioactivity materials used in the construction of the detector. For the second phase of the experiment (2005-2007), the detector will be upgraded by adding a shielding and including focusing optics. These improvements should allow for a background rejection better than two orders of magnitude.Comment: 6 pages, 3 figures To appear on the proceedings of the 9th ICATPP Conference on AStroparticle, Particle, Space Physics, Detectors and Medical Physics Application
    • …
    corecore