18 research outputs found

    High levels of B-type natriuretic peptide predict weaning failure from mechanical ventilation in adult patients after cardiac surgery

    Get PDF
    OBJECTIVE: The failure to wean from mechanical ventilation is related to worse outcomes after cardiac surgery. The aim of this study was to evaluate whether the serum level of B-type natriuretic peptide is a predictor of weaning failure from mechanical ventilation after cardiac surgery. METHODS: We conducted a prospective, observational cohort study of 101 patients who underwent on-pump coronary artery bypass grafting. B-type natriuretic peptide was measured postoperatively after intensive care unit admission and at the end of a 60-min spontaneous breathing test. The demographic data, hemodynamic and respiratory parameters, fluid balance, need for vasopressor or inotropic support, and length of the intensive care unit and hospital stays were recorded. Weaning failure was considered as either the inability to sustain spontaneous breathing after 60 min or the need for reintubation within 48 h. RESULTS: Of the 101 patients studied, 12 patients failed the weaning trial. There were no differences between the groups in the baseline or intraoperative characteristics, including left ventricular function, EuroSCORE and lengths of the cardiac procedure and cardiopulmonary bypass. The B-type natriuretic peptide levels were significantly higher at intensive care unit admission and at the end of the breathing test in the patients with weaning failure compared with the patients who were successfully weaned. In a multivariate model, a high B-type natriuretic peptide level at the end of a spontaneous breathing trial was the only independent predictor of weaning failure from mechanical ventilation. CONCLUSIONS: A high B-type natriuretic peptide level is a predictive factor for the failure to wean from mechanical ventilation after cardiac surgery. These findings suggest that optimizing ventricular function should be a goal during the perioperative period

    Hemodynamic Changes during Myocardial Revascularization without Extracorporeal Circulation

    Get PDF
    Background and objectives: Cardiac positioning and stabilization during myocardial revascularization without extracorporeal circulation (ECC) may cause hemodynamic changes dependent to the surgical site. The objective of this study was to evaluate these changes during distal coronary anastomosis. Methods: Twenty adult patients undergoing myocardial revascularization without ECC were monitored by pulmonary artery catheter and transesophageal Echo Doppler. Hemodynamic data were collected at the following times before removing the stabilizer wall: (1) after volume adjustments, (2) at the beginning of distal anastomosis, and (3) after 5 minutes. Treated coronary arteries were grouped according to their location in the lateral, anterior, or posterior wall. Two-way ANOVA with repetition and Newman-Keuls post-test were used in the analysis. A p value < 0.05 was considered statically significant. Results: During myocardial revascularization without ECC, pulmonary artery wedge pressure showed elevation from 17.7 +/- 6.1 to 19.2 +/- 6.5 (p < 0.001) and 19.4 +/- 5.9 mmHg (p < 0.001), while the central venous pressure went from 13.9 +/- 5.4 to 14.9 +/- 5.9 mmHg (p = 0.007) and 15.1 +/- 6.0 mmHg (p = 0.006). Intermittent cardiac output was reduced from 4.70 +/- 1.43 to 4.23 +/- 1.22 (p < 0.001) and 4.26 +/- 1.25 L.min(-1) (p < 0.001). According to transesophageal Doppler, a significant group-time interaction was observed in cardiac output, which was reduced in the lateral group from 4.08 +/- 1.99 to 2.84 +/- 1.82 (p = 0.02) and 2.86 +/- 1.73 L.min(-1) (p = 0.02), and aortic blood flow, which went from 2.85 +/- 1.39 to 1.99 +/- 1.26 (p = 0.02) and 2.00 +/- 1.21 L.min(-1) (p = 0.02). Other hemodynamic changes were not observed during anastomoses. Conclusions: A significant hemodynamic deterioration was observed during myocardial revascularization without ECC. Transesophageal Doppler detected a decrease in cardiac output only in the lateral group.Fundacao de Amparo a Pesquisa of the State of Sao Paulo (FAPESP)[03/07092-6

    Intraosseous Anesthesia in Hemodynamic Studies in Children with Cardiopathy

    Get PDF
    Aliman AC, Piccioni MA, Piccioni JL, Oliva JL, Auler Junior JOC - Intraosseous Anesthesia in Hemodynamic Studies in Children with Cardiopathy. Background and objectives: Intraosseous (IO) access has been used with good results in emergency situations, when venous access is not available for fluids and drugs infusion. The objective of this study was to evaluate IO a useful technique for anesthesia and fluids infusion during hemodynamic studies and when peripheral intravascular access is unobtainable. The setting was an university hospital hemodynamics unit, and the subjects were twenty one infants with congenital heart disease enrolled for elective hemodynamic study diagnosis. Methods: This study compared the effectiveness of IO access in relation to IV access for infusion of anesthetics agents (ketamine, midazolann, and fentanyl) and fluids during hemodynamic studies. The anesthetic induction time, procedure duration, anesthesia recovery time, adequate hydration, and IV and IO puncture complications were compared between groups. Results: The puncture time was significantly smaller in IO group (3.6 min) that in IV group (9.6 min). The anesthetic onset time (56.3 second) for the IV group was faster than IO group (71.3 second). No significant difference between groups were found in relation to hydration (IV group, 315.5 mL vs IO group, 293.2 mL), and anesthesia recovery time (IO group, 65.2 min vs IV group, 55.0 min). The puncture site was reevaluated after 7 and 15 days without signs of infection or other complications. Conclusions: Results showed superiority for IO infusion when considering the puncture time of the procedure. Due to its easy manipulation and efficiency, hydration and anesthesia by IO access was satisfactory for hemodynamic studies without the necessity of other infusion access

    Evaluation of hemodynamic effects of xenon in dogs undergoing hemorrhagic shock

    Get PDF
    OBJECTIVES: The anesthetic gas xenon is reported to preserve hemodynamic stability during general anesthesia. However, the effects of the gas during shock are unclear. The objective of this study was to evaluate the effect of Xe on hemodynamic stability and tissue perfusion in a canine model of hemorrhagic shock. METHOD: Twenty-six dogs, mechanically ventilated with a fraction of inspired oxygen of 21% and anesthetized with etomidate and vecuronium, were randomized into Xenon (Xe; n = 13) or Control (C; n = 13) groups. Following hemodynamic monitoring, a pressure-driven shock was induced to reach an arterial pressure of 40 mmHg. Hemodynamic data and blood samples were collected prior to bleeding, immediately after bleeding and 5, 20 and 40 minutes following shock. The Xe group was treated with 79% Xe diluted in ambient air, inhaled for 20 minutes after shock. RESULT: The mean bleeding volume was 44 mL.kg-1 in the C group and 40 mL.kg-1 in the Xe group. Hemorrhage promoted a decrease in both the cardiac index (p<0.001) and mean arterial pressure (p<0.001). These changes were associated with an increase in lactate levels and worsening of oxygen transport variables in both groups (p<0.05). Inhalation of xenon did not cause further worsening of hemodynamics or tissue perfusion markers. CONCLUSIONS: Xenon did not alter hemodynamic stability or tissue perfusion in an experimentally controlled hemorrhagic shock model. However, further studies are necessary to validate this drug in other contexts

    Penetration of cefuroxime in subcutaneous tissue during coronary artery bypass grafting surgery

    No full text
    A sensitive and rapid HPLC assay for determining cefuroxime penetration in the subcutaneous tissue near to surgical incision of patients submitted to coronary artery bypass grafting (CABC) with or without cardiopulmonary bypass (CPB) was performed. Blood and subcutaneous tissue samples were collected from 14 patients. in four periods during surgery. The analytical method presented linearity from 0.5 to 100 mu g/g. LOQ = 0.50 mu g/g, LOD = 0.25 mu g/g. intra- and interday precision (%CV) ranged from 4.9 to 8.9% and 6.4 to 9.9%, respectively, and intra-and interday accuracy expressed as % of the nominal concentration ranged from 87.1 to 104.6% and 94.8 to 103.8%, respectively (mean of three concentrations). Relative recovery was 98.4%. Tissue/plasma ratios obtained for CPB and non-CPB were, respectively: 14.6% vs 19.0% (0.6 h); 15.7% vs 15.7% (2.1 h); 22.5% vs 19.9% (3.6 h); 15.7% vs 18.8% (4.5 h). Data obtained indicate that tissue/plasma ratio remains unchanged in CPB and non-CPB patients during all period of surgery and the CPB does not affect the penetration of cefuroxime in tissues close to the surgical wound. (C) 2009 Elsevier B.V. All rights reserved.Brazilians foundations FAPESPCNP

    A Comparison Between Pulse Pressure Variation and Right End Diastolic Volume Index as Guides to Resuscitation in a Model of Hemorrhagic Shock in Pigs

    No full text
    Background: Different hemodynamic parameters including static indicators of cardiac preload as right ventricular end-diastolic volume index (RVEDVI) and dynamic parameters as pulse pressure variation (PPV) have been used in the decision-making process regarding volume expansion in critically ill patients. The objective of this study was to compare fluid resuscitation guided by either PPV or RVEDVI after experimentally induced hemorrhagic shock. Methods: Twenty-six anesthetized and mechanically ventilated pigs were allocated into control (group I), PPV (group II), or RVEDVI (group III) group. Hemorrhagic shock was induced by blood withdrawal to target mean arterial pressure of 40 mm Hg, maintained for 60 minutes. Parameters were measured at baseline, time of shock, 60 minutes after shock, immediately after resuscitation with hydroxyethyl starch 6% (130/0.4), 1 hour and 2 hours thereafter. The endpoint of fluid resuscitation was determined as the baseline values of PPV and RVEDVI. Statistical analysis of data was based on analysis of variance for repeated measures followed by the Bonferroni test (p < 0.05). Results: Volume and time to resuscitation were higher in group III than in group II (group III = 1,305 +/- 331 mL and group II = 965 +/- 245 mL, p < 0.05; and group III = 24.8 +/- 4.7 minutes and group II = 8.8 +/- 1.3 minutes, p < 0.05, respectively). All static and dynamic parameters and biomarkers of tissue oxygenation were affected by hemorrhagic shock and nearly all parameters were restored after resuscitation in both groups. Conclusion: In the proposed model of hemorrhagic shock, resuscitation to the established endpoints was achieved within a smaller amount of time and with less volume when guided by PPV than when guided by pulmonary artery catheter-derived RVEDVI.FAPESP[05/59470-0]Universidade de São Paulo - Laboratory of Medical Investigation (FM-USP)[FMUSP/LIM-08

    Pulse pressure variation and stroke volume variation under different inhaled concentrations of isoflurane, sevoflurane and desflurane in pigs undergoing hemorrhage.

    Get PDF
    OBJECTIVES: Inhalant anesthesia induces dose-dependent cardiovascular depression, but whether fluid responsiveness is differentially influenced by the inhalant agent and plasma volemia remains unknown. The aim of this study was to compare the effects of isoflurane, sevoflurane and desflurane on pulse pressure variation and stroke volume variation in pigs undergoing hemorrhage. METHODS: Twenty-five pigs were randomly anesthetized with isoflurane, sevoflurane or desflurane. Hemodynamic and echocardiographic data were registered sequentially at minimum alveolar concentrations of 1.00 (M1), 1.25 (M2), and 1.00 (M3). Then, following withdrawal of 30% of the estimated blood volume, these data were registered at a minimum alveolar concentrations of 1.00 (M4) and 1.25 (M5). RESULTS: The minimum alveolar concentration increase from 1.00 to 1.25 (M2) decreased the cardiac index and increased the central venous pressure, but only modest changes in mean arterial pressure, pulse pressure variation and stroke volume variation were observed in all groups from M1 to M2. A significant decrease in mean arterial pressure was only observed with desflurane. Following blood loss (M4), pulse pressure variation, stroke volume variation and central venous pressure increased (p < 0.001) and mean arterial pressure decreased in all groups. Under hypovolemia, the cardiac index decreased with the increase of anesthesia depth in a similar manner in all groups. CONCLUSION: The effects of desflurane, sevoflurane and isoflurane on pulse pressure variation and stroke volume variation were not different during normovolemia or hypovolemia

    A pragmatic multi-center trial of goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery

    Get PDF
    Background: Intraoperative fluid therapy guided by mechanical ventilation-induced pulse-pressure variation (PPV) may improve outcomes after major surgery. We tested this hypothesis in a multi-center study. Methods: The patients were included in two periods: a first control period (control groupn = 147) in which intraoperative fluids were given according to clinical judgment. After a training period, intraoperative fluid management was titrated to maintain PPV < 10% in 109 surgical patients (PPV group). We performed 1:1 propensity score matching to ensure the groups were comparable with regard to age, weight, duration of surgery, and type of operation. The primary endpoint was postoperative hospital length of stay. Results: After matching, 84 patients remained in each group. Baseline characteristics, surgical procedure duration and physiological parameters evaluated at the start of surgery were similar between the groups. The volume of crystalloids (4500 mL [3200-6500 mL] versus 5000 mL [3750-8862 mL]P = 0.01), the number of blood units infused during the surgery (1.7 U [0.9-2.0 U] versus 2.0 U [1.7-2.6 U]P = 0.01), the fraction of patients transfused (13.1% versus 32.1%P = 0.003) and the number of patients receiving mechanical ventilation at 24 h (3.2% versus 9.7%P = 0.027) were smaller postoperatively in PPV group. Intraoperative PPV-based improved the composite outcome of postoperative complications OR 0.59 [95% CI 0.35-0.99] and reduced the postoperative hospital length of stay (8 days [6-14 days] versus 11 days [7-18 days]P = 0.01). Conclusions: In high-risk surgeries, PPV-directed volume loading improved postoperative outcomes and decreased the postoperative hospital length of stay.DIXTAL BIOMEDICA INDUSTRIA E COMERCIO LIDAUniv Sao Paulo, Fac Med, Hosp Clin, Div Anestesia, Av Eneas Carvalho de Aguiar,255 2 Andar, BR-05403900 Sao Paulo, SP, BrazilHosp Padre Albino, Catanduva Med Sch, Catanduva, SP, BrazilUniv Fed Sao Paulo, Hosp Sao Paulo, Sao Paulo, SP, BrazilUniv Fed Sao Paulo, Hosp Sao Paulo, Sao Paulo, SP, BrazilWeb of Scienc

    Heart Rate Variability Analysis in an Experimental Model of Hemorrhagic Shock and Resuscitation in Pigs

    No full text
    <div><p>Background</p><p>The analysis of heart rate variability (HRV) has been shown as a promising non-invasive technique for assessing the cardiac autonomic modulation in trauma. The aim of this study was to evaluate HRV during hemorrhagic shock and fluid resuscitation, comparing to traditional hemodynamic and metabolic parameters.</p><p>Methods</p><p>Twenty anesthetized and mechanically ventilated pigs were submitted to hemorrhagic shock (60% of estimated blood volume) and evaluated for 60 minutes without fluid replacement. Surviving animals were treated with Ringer solution and evaluated for an additional period of 180 minutes. HRV metrics (time and frequency domain) as well as hemodynamic and metabolic parameters were evaluated in survivors and non-survivors animals.</p><p>Results</p><p>Seven of the 20 animals died during hemorrhage and initial fluid resuscitation. All animals presented an increase in time-domain HRV measures during haemorrhage and fluid resuscitation restored baseline values. Although not significantly, normalized low-frequency and LF/HF ratio decreased during early stages of haemorrhage, recovering baseline values later during hemorrhagic shock, and increased after fluid resuscitation. Non-surviving animals presented significantly lower mean arterial pressure (43±7vs57±9 mmHg, P<0.05) and cardiac index (1.7±0.2vs2.6±0.5 L/min/m<sup>2</sup>, P<0.05), and higher levels of plasma lactate (7.2±2.4vs3.7±1.4 mmol/L, P<0.05), base excess (-6.8±3.3vs-2.3±2.8 mmol/L, P<0.05) and potassium (5.3±0.6vs4.2±0.3 mmol/L, P<0.05) at 30 minutes after hemorrhagic shock compared with surviving animals.</p><p>Conclusions</p><p>The HRV increased early during hemorrhage but none of the evaluated HRV metrics was able to discriminate survivors from non-survivors during hemorrhagic shock. Moreover, metabolic and hemodynamic variables were more reliable to reflect hemorrhagic shock severity than HRV metrics.</p></div
    corecore