729 research outputs found

    Synthesis and characterization of attosecond light vortices in the extreme ultraviolet

    Get PDF
    Infrared and visible light beams carrying orbital angular momentum (OAM) are currently thoroughly studied for their extremely broad applicative prospects, among which are quantum information, micromachining and diagnostic tools. Here we extend these prospects, presenting a comprehensive study for the synthesis and full characterization of optical vortices carrying OAM in the extreme ultraviolet (XUV) domain. We confirm the upconversion rules of a femtosecond infrared helically phased beam into its high-order harmonics, showing that each harmonic order carries the total number of OAM units absorbed in the process up to very high orders (57). This allows us to synthesize and characterize helically shaped XUV trains of attosecond pulses. To demonstrate a typical use of these new XUV light beams, we show our ability to generate and control, through photoionization, attosecond electron beams carrying OAM. These breakthroughs pave the route for the study of a series of fundamental phenomena and the development of new ultrafast diagnosis tools using either photonic or electronic vortices

    Professionalization of Educational Leadership for the Members of the Association of African Universities

    Get PDF
    This study sets out to theorize and conceptualize internal stakeholders’ provision of Educational Leadership for the Members of the Association of African Universities (AAU). It reviews research materials, policies and modalities in developing educational leadership, African Philosophies of Education (APE) and interviews of university academic staff and students in measuring the success of professionalization of educational leadership. The purposive sampling technique of data collection is used to ensure representativeness and qualitative methodology, including the use of document-based content analysis in order to generate valid, reliable and rich data based on interviews with academic staff, administrators and students. The findings of this study will contribute to the deeper understanding of internal stakeholders’ provision of a decolonized Educational Leadership Curriculum (DELC) objective at Postgraduate Diploma, Master’s and Doctorate programmes in Educational Leadership is therefore proposed for African universities. This will enable education leader, schools and School system leaders to play a critical role in having a clear vision, the ability to communicate the vision to team members, the ability to organize in an effective and efficient manner, inspiring subordinates towards the fulfillment of the organization’s goals, and balancing the conflict of interest of all subordinates and stakeholders. The proposed leadership learning programs focus on the actual improvement of schools and the educational systems to achieve equity, diversity, social inclusion, peace, economic growth and prosperity. These leadership programmes will address the challenges of developing human capital and well-being, promoting employment and economic integration, governance, strategic management and democracy in the different African union countries

    The effect of heterobifunctional crosslinkers on HEMA hydrogel modulus and toughness

    Full text link
    The use of hydrogels in load bearing applications is often limited by insufficient toughness. 2-Hydroxyethyl methacrylate (HEMA) based hydrogels are appealing for translational work, as they are affordable and the use of HEMA is FDA approved. Furthermore, HEMA is photopolymerizable, providing spatiotemporal control over mechanical properties. We evaluated the ability of vinyl methacrylate (VM), allyl methacrylate (AM), and 3-(Acryloyloxy)-2-hydroxypropyl methacrylate (AHPM) to tune hydrogel toughness and Young’s modulus. The crosslinkers were selected due to their heterobifunctionality (vinyl and methacrylate) and similar size and structure to EGDMA, which was shown previously to increase toughness as compared to longer crosslinkers. Vinyl methacrylate incorporation into HEMA hydrogels gave rise to hydrogels with Young’s moduli spanning ranges for ligament to cartilage, with a peak toughness of 519 ± 70 kJ/m3 under physiological conditions. We report toughness (work of extension) as a function of modulus and equilibrium water content for all formulations. The hydrogels exhibited 80%-100% cell viability, which suggests they could be used in tissue engineering applications

    Evaluating PET-CT in the detection and management of recurrent cervical cancer: Systematic reviews of diagnostic accuracy and subjective elicitation

    Get PDF
    Background: Positron emission tomography-computed tomography (PET-CT) is recommended to triage women for exenterative surgery and surveillance after treatment for advanced cervical cancer. Objective: To evaluate diagnostic accuracy of additional whole body PET-CT compared with CT/magnetic resonance imaging (MRI) alone in women with suspected recurrent/persistent cervical cancer and in asymptomatic women as surveillance. Design: Systematic reviews. Subjective elicitation to supplement diagnostic information. Search strategy/Selection criteria/Data collection and analysis: Searches of electronic databases were performed to June 2013. Studies in women with suspected recurrent/persistent cervical cancer and in asymptomatic women undergoing follow up with sufficient numeric data were included. We calculated sensitivity, specificity and corresponding 95% confidence intervals. Meta-analyses employed a bivariate model that included a random-effects term for between-study variations (CT studies) and univariate random effects meta-analyses (PET-CT studies) for sensitivity and specificity separately. Subjective elicitation: Prevalence of recurrence and the accuracy of imaging elicited using the allocation of points technique. Coherence of elicited subjective probabilities with estimates in the literature examined. Results: We identified 15 relevant studies; none directly compared additional PET-CT with MRI or CT separately. Most CT and MRI studies used older protocols and the majority did not distinguish between asymptomatic and symptomatic women. Meta-analysis of nine PET-CT studies in mostly symptomatic women showed sensitivity of 94.8 (95% CI 91.2-96.9), and specificity of 86.9% (95% CI 82.2-90.5). The summary estimate of the sensitivity of CT for detection of recurrence was 89.64% (95% CI 81.59-94.41) and specificity was 76% (95% CI 43.68-92.82). Meta-analysis for MRI test accuracy studies was not possible because of clinical heterogeneity. The sensitivity and specificity of MRI in pelvic recurrence varied between 82 and 100% and between 78 and 100%, respectively. Formal statistical comparisons of the accuracy of index tests were not possible. Subjective elicitation provided estimates comparable to the literature. Subjective estimates of the increase in accuracy from the addition of PET-CT were less than elicited increases required to justify the use in PET-CT for surveillance. Conclusion: Evidence to support additional PET-CT is scarce, of average quality and does not distinguish between application for surveillance and diagnosis. Guidelines recommending PET-CT in recurrent cervical cancer need to be reconsidered in the light of the existing evidence base

    Bioresponsive matrices in drug delivery

    Get PDF
    For years, the field of drug delivery has focused on (1) controlling the release of a therapeutic and (2) targeting the therapeutic to a specific cell type. These research endeavors have concentrated mainly on the development of new degradable polymers and molecule-labeled drug delivery vehicles. Recent interest in biomaterials that respond to their environment have opened new methods to trigger the release of drugs and localize the therapeutic within a particular site. These novel biomaterials, usually termed "smart" or "intelligent", are able to deliver a therapeutic agent based on either environmental cues or a remote stimulus. Stimuli-responsive materials could potentially elicit a therapeutically effective dose without adverse side effects. Polymers responding to different stimuli, such as pH, light, temperature, ultrasound, magnetism, or biomolecules have been investigated as potential drug delivery vehicles. This review describes the most recent advances in "smart" drug delivery systems that respond to one or multiple stimuli

    Positron emission tomography/computerised tomography imaging in detecting and managing recurrent cervical cancer: systematic review of evidence, elicitation of subjective probabilities and economic modelling.

    Get PDF
    © Queen’s Printer and Controller of HMSO 2013. This work was produced by Meads et al. under the terms of a commissioning contract issued by the Secretary of State for Health. This issue may be freely reproduced for the purposes of private research and study and extracts (or indeed, the full report) may be included in professional journals provided that suitable acknowledgement is made and the reproduction is not associated with any form of advertising.Cancer of the uterine cervix is a common cause of mortality in women. After initial treatment women may be symptom free, but the cancer may recur within a few years. It is uncertain whether it is more clinically effective to survey asymptomatic women for signs of recurrence or to await symptoms or signs before using imaging.National Institute for Health Research Health Technology Assessment programm

    First Results of the Phase II SIMPLE Dark Matter Search

    Full text link
    We report results of a 14.1 kgd measurement with 15 superheated droplet detectors of total active mass 0.208 kg, comprising the first stage of a 30 kgd Phase II experiment. In combination with the results of the neutron-spin sensitive XENON10 experiment, these results yield a limit of |a_p| < 0.32 for M_W = 50 GeV/c2 on the spin-dependent sector of weakly interacting massive particle-nucleus interactions with a 50% reduction in the previously allowed region of the phase space formerly defined by XENON, KIMS and PICASSO. In the spin-independent sector, a limit of 2.3x10-5 pb at M_W = 45 GeV/c2 is obtained.Comment: 4 pages, 4 figures; PRL-accepted version with corrected SI contour (Fig. 4

    Kikuchi-Fujimoto Disease Masquerading as Metastatic Papillary Carcinoma of the Thyroid

    Get PDF
    Kikuchi-Fujimoto disease also known as histiocytic necrotizing lymphadenitis is a rare cervical inflammatory lymphadenitis that is most commonly seen in young Asian women. It is mainly characterized by lymphadenopathy, hepatosplenomegaly, fever, nocturnal sweats, myalgia, weight loss, and arthralgia, and commonly follows a self-limited course. The differential diagnosis is challenging as many other conditions such as malignant lymphoma, metastatic disease, tuberculosis and infectious lymphadenopathies can present in a similar way. We present an unusual case of Kikuchi-Fujimoto disease masquerading as metastatic papillary carcinoma of the thyroid. A 30-year-old young female presented, 2 months post-partum, with complaints of neck pain and fever. A computed tomography scan showed enlarged right-sided lymph nodes and a thyroid nodule. Subsequent biopsy of a thyroid nodule revealed papillary thyroid carcinoma and reactive inflammation in one of the lymph nodes. She underwent an elective total thyroidectomy, central node dissection and a right modified lymph node dissection for enlarged lymph nodes. Her recovery was uneventful and the pathology report was consistent with a papillary carcinoma of the thyroid with one lymph node positive for metastatic disease and several other lymph nodes showing histiocytic necrotizing lymphadenitis. This coexistence of Kikuchi-Fujimoto disease with localized metastatic papillary thyroid cancer is unusual and presents an interesting, challenging, and complex management dilemma

    Final Analysis and Results of the Phase II SIMPLE Dark Matter Search

    Full text link
    We report the final results of the Phase II SIMPLE measurements, comprising two run stages of 15 superheated droplet detectors each, the second stage including an improved neutron shielding. The analyses includes a refined signal analysis, and revised nucleation efficiency based on reanalysis of previously-reported monochromatic neutron irradiations. The combined results yield a contour minimum of \sigma_{p} = 4.2 x 10^-3 pb at 35 GeV/c^2 on the spin-dependent sector of WIMP-proton interactions, the most restrictive to date from a direct search experiment and overlapping for the first time results previously obtained only indirectly. In the spin-independent sector, a minimum of 3.6 x 10^-6 pb at 35 GeV/c^2 is achieved, with the exclusion contour challenging the recent CoGeNT region of current interest.Comment: revised, PRL-accepted version with slightly weakened limit contour

    Association of hydrophobically-modified poly(ethylene glycol) with fusogenic liposomes

    Get PDF
    AbstractWe present results on using cooperative interactions to shield liposomes by incorporating multiple hydrophobic anchoring sites on polyethylene glycol (PEG) polymers. The hydrophobically-modified PEGs (HMPEGs) are comb-graft polymers with strictly alternating monodisperse PEG blocks (Mw=6, 12, or 35 kDa) bonded to C18 stearylamide hydrophobes. Cooperativity is varied by changing the degree of oligomerization at a constant ratio of PEG to stearylamide. Fusogenic liposomes prepared from N-C12-DOPE:DOPC 7:3 (mol:mol) were equilibrated with HMPEGs. Affinity for polymer association to liposomes increases with the degree of oligomerization; equilibrium constants (given as surface coverage per equilibrium concentration of free polymer) for 6 kDa PEG increased from 6.1±0.8 (mg/m2)/(mg/ml) for 2.5 loops to 78.1±12.2 (mg/m2)/(mg/ml) for 13 loops. In contrast, the equilibrium constant for distearoylphosphatidylethanolamine-poly(ethylene glycol) (DSPE-PEG5k) was 0.4±0.1 (mg/m2)/(mg/ml).The multi-loop HMPEGs demonstrate higher levels of protection from complement binding than DSPE-PEG5k. Greater protection does not correlate with binding strength alone. The best shielding was by HMPEG6k-DP3 (with three 6 kDa PEG loops), suggesting that PEG chains with adequate surface mobility provide optimal protection from complement opsonization. Complement binding at 30 min and 12 h demonstrates that protection by multi-looped PEGs is constant whereas DSPE-PEG5k initially protects but presumably partitions off of the surface at longer times
    corecore