235 research outputs found

    Vascular variations of the kidney, retrospective analysis of computed tomography images of ninety-one laparoscopic donor nephrectomies, and comparison of computed tomography images with perioperative findings

    Get PDF
    Background: In this retrospective study, we aimed to determine the variations of kidney arteries and veins in kidney donor patients who underwent preoperative, computed tomography angiography (CTA).Materials and methods: We analysed kidney CTA findings of 91 donor nephrectomy patients operated from July 2016 through December 2017. Demographics, vascular diameters, abnormalities, numbers, branching variations, routing variations of arteries, and veins were assessed according to CTA images. We also compared the radiological findings with perioperative findings. Two radiologists evaluated CTA images, and the same surgical team performed all donor nephrectomies by laparoscopic approach.Results: Ninety-one of the 96 patients involved to study. Forty-six (50.5%) patients were female. Thirty-five (38.4%) of 91 cases had accessory arteries. Seven (7.6%) right, 1 (1.1%) left and 8 (8.7%) bilateral double hilar artery was observed on CTA. No statistically significant difference was observed in the evaluation of the side of accessory/polar arteries (p > 0.05), and in the evaluation of the distribution of arterial/venous variations according to perioperative findings (p > 0.05). However, in the evaluation of CTA images, we found that the diameter of the kidney artery and vein differed according to gender and side.Conclusions: The knowledge of the vascular variations of the kidney is essential for surgeons performing kidney transplantation. It is also essential for urologist and vascular surgeons. Incompatible with the literature, the right kidney has more vascular variations and, one kidney artery is found in the majority of Turkish kidneydonor patients

    Cutting tool tracking and recognition based on infrared and visual imaging systems using principal component analysis (PCA) and discrete wavelet transform (DWT) combined with neural networks

    Get PDF
    The implementation of computerised condition monitoring systems for the detection cutting tools’ correct installation and fault diagnosis is of a high importance in modern manufacturing industries. The primary function of a condition monitoring system is to check the existence of the tool before starting any machining process and ensure its health during operation. The aim of this study is to assess the detection of the existence of the tool in the spindle and its health (i.e. normal or broken) using infrared and vision systems as a non-contact methodology. The application of Principal Component Analysis (PCA) and Discrete Wavelet Transform (DWT) combined with neural networks are investigated using both types of data in order to establish an effective and reliable novel software program for tool tracking and health recognition. Infrared and visual cameras are used to locate and track the cutting tool during the machining process using a suitable analysis and image processing algorithms. The capabilities of PCA and Discrete Wavelet Transform (DWT) combined with neural networks are investigated in recognising the tool’s condition by comparing the characteristics of the tool to those of known conditions in the training set. The experimental results have shown high performance when using the infrared data in comparison to visual images for the selected image and signal processing algorithms

    Influence of Test Procedures on the Thermomechanical Properties of a 55NiTi Shape Memory Alloy

    Get PDF
    Over the past few decades, binary NiTi shape memory alloys have received attention due to their unique mechanical characteristics, leading to their potential use in low-temperature, solid-state actuator applications. However, prior to using these materials for such applications, the physical response of these systems to mechanical and thermal stimuli must be thoroughly understood and modeled to aid designers in developing SMA-enabled systems. Even though shape memory alloys have been around for almost five decades, very little effort has been made to standardize testing procedures. Although some standards for measuring the transformation temperatures of SMA s are available, no real standards exist for determining the various mechanical and thermomechanical properties that govern the usefulness of these unique materials. Consequently, this study involved testing a 55NiTi alloy using a variety of different test methodologies. All samples tested were taken from the same heat and batch to remove the influence of sample pedigree on the observed results. When the material was tested under constant-stress, thermal-cycle conditions, variations in the characteristic material responses were observed, depending on test methodology. The transformation strain and irreversible strain were impacted more than the transformation temperatures, which only showed an affect with regard to applied external stress. In some cases, test methodology altered the transformation strain by 0.005-0.01mm/mm, which translates into a difference in work output capability of approximately 2 J/cu cm (290 in!lbf/cu in). These results indicate the need for the development of testing standards so that meaningful data can be generated and successfully incorporated into viable models and hardware. The use of consistent testing procedures is also important when comparing results from one research organization to another. To this end, differences in the observed responses will be presented, contrasted and rationalized, in hopes of eventually developing standardized testing procedures for shape memory alloys

    Cell-phone traces reveal infection-associated behavioral change

    Get PDF
    To access publisher's full text version of this article, please click on the hyperlink in Additional Links field or click on the hyperlink at the top of the page marked DownloadEpidemic preparedness depends on our ability to predict the trajectory of an epidemic and the human behavior that drives spread in the event of an outbreak. Changes to behavior during an outbreak limit the reliability of syndromic surveillance using large-scale data sources, such as online social media or search behavior, which could otherwise supplement healthcare-based outbreak-prediction methods. Here, we measure behavior change reflected in mobile-phone call-detail records (CDRs), a source of passively collected real-time behavioral information, using an anonymously linked dataset of cell-phone users and their date of influenza-like illness diagnosis during the 2009 H1N1v pandemic. We demonstrate that mobile-phone use during illness differs measurably from routine behavior: Diagnosed individuals exhibit less movement than normal (1.1 to 1.4 fewer unique tower locations; [Formula: see text]), on average, in the 2 to 4 d around diagnosis and place fewer calls (2.3 to 3.3 fewer calls; [Formula: see text]) while spending longer on the phone (41- to 66-s average increase; [Formula: see text]) than usual on the day following diagnosis. The results suggest that anonymously linked CDRs and health data may be sufficiently granular to augment epidemic surveillance efforts and that infectious disease-modeling efforts lacking explicit behavior-change mechanisms need to be revisited. Keywords: call detail records; disease; influenza; outbreak; surveillance.Alan Turing Institute Engineering and Physical Sciences Research Council EP/N510129/1 UK Research & Innovation (UKRI) Medical Research Council UK (MRC) European Commission National Institute for Health Research (NIHR) Health Protection Research Unit in Evaluation of Interventions at the University of Brist

    Intrabiliary rupture of liver hydatid cyst: a case report and review of the literature

    Get PDF
    Herein, we report a 66 year old woman who was diagnosed to have intrabiliary rupture of liver hydatid cyst with demonstrative computed tomography, magnetic resonance imaging, and magnetic resonance cholangiopancreatography findings, with a review of the literature

    HySenS data exploitation for urban land cover analysis

    Get PDF
    This paper addresses the use of HySenS airborne hyperspectral data for environmental urban monitoring. It is known that hyperspectral data can help to characterize some of the relations between soil composition, vegetation characteristics, and natural/artificial materials in urbanized areas. During the project we collected DAIS and ROSIS data over the urban test area of Pavia, Northern Italy, though due to a late delivery of ROSIS data only DAIS data was used in this work. Here we show results referring to an accurate characterization and classification of land cover/use, using different supervised approaches, exploiting spectral as well as spatial information. We demonstrate the possibility to extract from the hyperspectral data information which is very useful for environmental characterization of urban areas

    Cardiorespiratory effects of venous lipid micro embolization in an experimental model of mediastinal shed blood reinfusion

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Retransfusion of the patient's own blood during surgery is used to reduce the need for allogenic blood transfusion. It has however been found that this blood contains lipid particles, which form emboli in different organs if the blood is retransfused on the arterial side. In this study, we tested whether retransfusion of blood containing lipid micro-particles on the venous side in a porcine model will give hemodynamic effects.</p> <p>Methods</p> <p>Seven adult pigs were used. A shed blood surrogate containing 400 ml diluted blood and 5 ml radioactive triolein was produced to generate a lipid embolic load. The shed blood surrogate was rapidly (<2 minutes) retransfused from a transfusion bag to the right atrium under general anesthesia. The animals' arterial, pulmonary, right and left atrial pressure were monitored, together with cardiac output and deadspace. At the end of the experiment, an increase in cardiac output and pulmonary pressure was pharmacologically induced to try to flush out lipid particles from the lungs.</p> <p>Results</p> <p>A more than 30-fold increase in pulmonary vascular resistance was observed, with subsequent increase in pulmonary artery pressure, and decrease in cardiac output and arterial pressure. This response was transient, but was followed by a smaller, persistent increase in pulmonary vascular resistance. Only a small portion of the infused triolein passed the lungs, and only a small fraction could be recirculated by increasing cardiac output and pulmonary pressure.</p> <p>Conclusion</p> <p>Infusion of blood containing lipid micro-emboli on the venous side leads to acute, severe hemodynamic responses that can be life threatening. Lipid particles will be trapped in the lungs, leading to persistent effects on the pulmonary vascular resistance.</p
    • 

    corecore