20 research outputs found

    Grip control and motor coordination with implanted and surface electrodes while grasping with an osseointegrated prosthetic hand

    Get PDF
    Background: Replacement of a lost limb by an artificial substitute is not yet ideal. Resolution and coordination of motor control approximating that of a biological limb could dramatically improve the functionality of prosthetic devices, and thus reduce the gap towards a suitable limb replacement. Methods: In this study, we investigated the control resolution and coordination exhibited by subjects with transhumeral amputation who were implanted with epimysial electrodes and an osseointegrated interface that provides bidirectional communication in addition to skeletal attachment (e-OPRA Implant System). We assessed control resolution and coordination in the context of routine and delicate grasping using the Pick and Lift and the Virtual Eggs Tests. Performance when utilizing implanted electrodes was compared with the standard-of-care technology for myoelectric prostheses, namely surface electrodes. Results: Results showed that implanted electrodes provide superior controllability over the prosthetic terminal device compared to conventional surface electrodes. Significant improvements were found in the control of the grip force and its reliability during object transfer. However, these improvements failed to increase motor coordination, and surprisingly decreased the temporal correlation between grip and load forces observed with surface electrodes. We found that despite being more functional and reliable, prosthetic control via implanted electrodes still depended highly on visual feedback. Conclusions: Our findings indicate that incidental sensory feedback (visual, auditory, and osseoperceptive in this case) is insufficient for restoring natural grasp behavior in amputees, and support the idea that supplemental tactile sensory feedback is needed to learn and maintain the motor tasks internal model, which could ultimately restore natural grasp behavior in subjects using prosthetic hands

    Spinal cord from body donors is suitable for multicolor immunofluorescence

    Get PDF
    Immunohistochemistry is a powerful tool for studying neuronal tissue from humans at the molecular level. Obtaining fresh neuronal tissue from human organ donors is difficult and sometimes impossible. In anatomical body donations, neuronal tissue is dedicated to research purposes and because of its easier availability, it may be an alternative source for research. In this study, we harvested spinal cord from a single organ donor 2 h (h) postmortem and spinal cord from body donors 24, 48, and 72 h postmortem and tested how long after death, valid multi-color immunofluorescence or horseradish peroxidase (HRP) immunohistochemistry is possible. We used general and specific neuronal markers and glial markers for immunolabeling experiments. Here we showed that it is possible to visualize molecularly different neuronal elements with high precision in the body donor spinal cord 24 h postmortem and the quality of the image data was comparable to those from the fresh organ donor spinal cord. High-contrast multicolor images of the 24-h spinal cords allowed accurate automated quantification of different neuronal elements in the same sample. Although there was antibody-specific signal reduction over postmortem intervals, the signal quality for most antibodies was acceptable at 48 h but no longer at 72 h postmortem. In conclusion, our study has defined a postmortem time window of more than 24 h during which valid immunohistochemical information can be obtained from the body donor spinal cord. Due to the easier availability, neuronal tissue from body donors is an alternative source for basic and clinical research

    The long-term effects of an implantable drop foot stimulator on gait in hemiparetic patients

    Get PDF
    Drop foot is a frequent abnormality in gait after central nervous system lesions. Different treatment strategies are available to functionally restore dorsal extension during swing phase in gait. Orthoses as well as surface and implantable devices for electrical stimulation of the peroneal nerve may be used in patients who do not regain good dorsal extension. While several studies investigated the effects of implanted systems on walking speed and gait endurance, only a few studies have focussed on the system’s impact on kinematics and long-term outcomes. Therefore, our aim was to further investigate the effects of the implanted system ActiGait on gait kinematics and spatiotemporal parameters for the first time with a 1-year follow-up period. 10 patients were implanted with an ActiGait stimulator, with 8 patients completing baseline and follow-up assessments. Assessments included a 10-m walking test, video-based gait analysis and a Visual Analogue Scale (VAS) for health status. At baseline, gait analysis was performed without any assistive device as well as with surface electrical stimulation. At follow-up patients walked with the ActiGait system switched off and on. The maximum dorsal extension of the ankle at initial contact increased significantly between baseline without stimulation and follow-up with ActiGait (p = 0.018). While the spatio-temporal parameters did not seem to change much with the use of ActiGait in convenient walking speed, patients did walk faster when using surface stimulation or ActiGait compared to no stimulation at the 10-m walking test at their fastest possible walking speed. Patients rated their health better at the 1-year follow-up. In summary, a global improvement in gait kinematics compared to no stimulation was observed and the long-term safety of the device could be confirmed

    PlayBionic: Interactive rehabilitation for patients after nerve transfer or upper extremity amputation

    No full text

    Rehabilitations-App zur spielerischen Verbesserung der prothetischen Kontrolle

    No full text

    Videospiele als interaktive Rehablitationsmethode zum Erlernen der Steuerung einer myoelektrischen Prothese

    No full text

    Bidirectional bionic limbs: a perspective bridging technology and physiology

    No full text
    Precise control of bionic limbs relies on robust decoding of motor commands from nerves or muscles signals and sensory feedback from artificial limbs to the nervous system by interfacing the afferent nerve pathways. Implantable devices for bidirectional communication with bionic limbs have been developed in parallel with research on physiological alterations caused by an amputation. In this perspective article, we question whether increasing our effort on bridging these technologies with a deeper understanding of amputation pathophysiology and human motor control may help to overcome pressing stalls in the next generation of bionic limbs.TN

    Simultaneous GDNF and BDNF application leads to increased motoneuron survival and improved functional outcome in an experimental model for obstetric brachial plexus lesions

    No full text
    Motoneurons of the neonate rat respond to proximal axonal injury with morphologic and functional changes and ultimately with neuronal death. Recent studies showed that both glial cell-line-derived neurotrophic factor (GDNF) and brain-derived neurotrophic factor (BDNF) reduce induced degeneration of motoneurons after axotomy and avulsion. Whether rescued motoneurons are functionally intact has been argued. In the present investigation, the authors have used a proximal crush lesion of the brachial plexus in neonatal rats as the experimental model of neuronal injury. This allowed the authors to study the effects of trophic factor administration on injured motoneurons and the relationship between motoneuron survival and extremity function. Trophic factors were locally released by small polymer implants in a low-dose slow-release mode. Six groups of 10 animals were prepared: BDNF, GDNF, GDNF/BDNF, control, sham, and normals. The number of surviving motoneurons was determined by retrograde tracer techniques using Fluorogold and Fastblue. Extremity function was quantitatively evaluated with functional muscle testing at day 56. The results of this study demonstrate that trophic factors applied separately had no effect, whereas combined trophic factor application (GDNF/BDNF group) had a dramatic rescue effect on motoneuron survival as compared with the control groups, which also effected significantly greater strength. The authors conclude that a combination of trophic factors leads to enhanced motoneuron survival, with improved voluntary function as the animal enters adulthood so that exogenous trophic support of motoneurons might have a role in the treatment of all types of severe neonatal plexopathies, maintaining the viability of motoneurons until reconstructive surgery provides them with a pathway for regeneration and endogenous trophic support
    corecore