656 research outputs found
Application of steady state finite element and transient finite difference theory to sound propagation in a variable area duct: A comparison with experiment
Sound propagation without flow in a rectangular duct with a converging-diverging area variation was studied experimentally and theoretically. The area variation was of sufficient magnitude to produce large reflections and induce modal scattering. The rms (root-mean-squared) pressure and phase angle on both the flat and curved surface were measured and tabulated. The steady state finite element theory and the transient finite difference theory are in good agreement with the data. It is concluded that numerical finite difference and finite element theories appear ideally suited for handling duct propagation problems which encounter large area variations
On Resilient Behaviors in Computational Systems and Environments
The present article introduces a reference framework for discussing
resilience of computational systems. Rather than a property that may or may not
be exhibited by a system, resilience is interpreted here as the emerging result
of a dynamic process. Said process represents the dynamic interplay between the
behaviors exercised by a system and those of the environment it is set to
operate in. As a result of this interpretation, coherent definitions of several
aspects of resilience can be derived and proposed, including elasticity, change
tolerance, and antifragility. Definitions are also provided for measures of the
risk of unresilience as well as for the optimal match of a given resilient
design with respect to the current environmental conditions. Finally, a
resilience strategy based on our model is exemplified through a simple
scenario.Comment: The final publication is available at Springer via
http://dx.doi.org/10.1007/s40860-015-0002-6 The paper considerably extends
the results of two conference papers that are available at http://ow.ly/KWfkj
and http://ow.ly/KWfgO. Text and formalism in those papers has been used or
adapted in the herewith submitted pape
A method for exploratory repeated-measures analysis applied to a breast-cancer screening study
When a model may be fitted separately to each individual statistical unit,
inspection of the point estimates may help the statistician to understand
between-individual variability and to identify possible relationships. However,
some information will be lost in such an approach because estimation
uncertainty is disregarded. We present a comparative method for exploratory
repeated-measures analysis to complement the point estimates that was motivated
by and is demonstrated by analysis of data from the CADET II breast-cancer
screening study. The approach helped to flag up some unusual reader behavior,
to assess differences in performance, and to identify potential random-effects
models for further analysis.Comment: Published in at http://dx.doi.org/10.1214/11-AOAS481 the Annals of
Applied Statistics (http://www.imstat.org/aoas/) by the Institute of
Mathematical Statistics (http://www.imstat.org
The impact of gender on the risk of cardiovascular events in older adults with advanced chronic kidney disease
Background. Patients with chronic kidney disease (CKD) are at a higher risk of major adverse cardiovascular events (MACE) compared with the general population, but gender differences in this risk, especially in older adults, are not fully known.We aim to identify gender differences in the risk of MACE in older European CKD patients, and explore factors that may explain these differences. Methods. The European Quality study (EQUAL) is a prospective study on stage 4-5 CKD patients, ≥65 years old, not on dialysis, from Germany, Italy, the Netherlands, Poland, Sweden and the UK. Cox regression and cumulative incidence competing risk curves were used to identify gender differences in MACE risks. Mediation analysis was used to identify variables which may explain risk differences between men and women. Results. A total of 417 men out of 1134 (37%) and 185 women out of 602 women (31%) experienced at least one MACE, over a follow-up period of 5 years.Women had an 18% lower risk of first MACE compared with men (hazard ratio 0.82; 95% confidence interval 0.69-0.97; P = .02), which was attenuated after adjusting for pre-existing cardiometabolic comorbidities and cardiovascular risk factors. There were no significant gender differences in the risk of recurrent MACE or fatal MACE. The risk difference in MACE by gender was larger in patients aged 65-75 years, compared with patients over 75 years. Conclusions. In a cohort of older adults with advanced CKD, women had lower risks of MACE. These risk differences were partially explained by pre-existing cardiometabolic comorbidities and cardiovascular risk factors.</p
Accuracy of Digital Breast Tomosynthesis for Depicting Breast Cancer Subgroups in a UK Retrospective Reading Study (TOMMY Trial)
Purpose
To compare the diagnostic performance of two-dimensional (2D) mammography, 2D mammography plus digital breast tomosynthesis (DBT), and synthetic 2D mammography plus DBT in depicting malignant radiographic features.
Materials and Methods
In this multicenter, multireader, retrospective reading study (the TOMMY trial), after written informed consent was obtained, 8869 women (age range, 29–85 years; mean, 56 years) were recruited from July 2011 to March 2013 in an ethically approved study. From these women, a reading dataset of 7060 cases was randomly allocated for independent blinded review of (a) 2D mammography images, (b) 2D mammography plus DBT images, and (c) synthetic 2D mammography plus DBT images. Reviewers had no access to results of previous examinations. Overall sensitivities and specificities were calculated for younger women and those with dense breasts.
Results
Overall sensitivity was 87% for 2D mammography, 89% for 2D mammography plus DBT, and 88% for synthetic 2D mammography plus DBT. The addition of DBT was associated with a 34% increase in the odds of depicting cancer (odds ratio [OR] = 1.34, P = .06); however, this level did not achieve significance. For patients aged 50–59 years old, sensitivity was significantly higher (P = .01) for 2D mammography plus DBT than it was for 2D mammography. For those with breast density of 50% or more, sensitivity was 86% for 2D mammography compared with 93% for 2D mammography plus DBT (P = .03). Specificity was 57% for 2D mammography, 70% for 2D mammography plus DBT, and 72% for synthetic 2D mammography plusmDBT. Specificity was significantly higher than 2D mammography (P < .001in both cases) and was observed for all subgroups (P < .001 for all cases).
Conclusion
The addition of DBT increased the sensitivity of 2D mammography in patients with dense breasts and the specificity of 2D mammography for all subgroups. The use of synthetic 2D DBT demonstrated performance similar to that of standard 2D mammography with DBT. DBT is of potential benefit to screening programs, particularly in younger women with dense breasts.
© RSNA, 2015The TOMMY Trial (a comparison of digital breast tomosynthesis with mammography in the UK Breast Screening Programme) was supported by the NIHR Health Technology Assessment Programme.This is the final published version of the article. It was originally published in Radiology (Gilbert et al., Radiology, 2015, doi:10.1148/radiol.2015142566). The final version is available at http://dx.doi.org/10.1148/radiol.201514256
Symptoms and syndromes associated with SARS-CoV-2 infection and severity in pregnant women from two community cohorts
We tested whether pregnant and non-pregnant women differ in COVID-19 symptom profile and severity, and we extended previous investigations on hospitalized pregnant women to those who did not require hospitalization. Two female community-based cohorts (18-44 years) provided longitudinal (smartphone application, N = 1,170,315, n = 79 pregnant tested positive) and cross-sectional (web-based survey, N = 1,344,966, n = 134 pregnant tested positive) data, prospectively collected through self-participatory citizen surveillance in UK, Sweden and USA. Pregnant and non-pregnant were compared for frequencies of events, including SARS-CoV-2 testing, symptoms and hospitalization rates. Multivariable regression was used to investigate symptoms severity and comorbidity effects. Pregnant and non-pregnant women positive for SARS-CoV-2 infection were not different in syndromic severity, except for gastrointestinal symptoms. Pregnant were more likely to have received testing, despite reporting fewer symptoms. Pre-existing lung disease was most closely associated with syndromic severity in pregnant hospitalized. Heart and kidney diseases and diabetes increased risk. The most frequent symptoms among non-hospitalized women were anosmia [63% pregnant, 92% non-pregnant] and headache [72%, 62%]. Cardiopulmonary symptoms, including persistent cough [80%] and chest pain [73%], were more frequent among pregnant who were hospitalized. Consistent with observations in non-pregnant populations, lung disease and diabetes were associated with increased risk of more severe SARS-CoV-2 infection during pregnancy
Accuracy of Digital Breast Tomosynthesis for Depicting Breast Cancer Subgroups in a UK Retrospective Reading Study (TOMMY Trial).
PURPOSE: To compare the diagnostic performance of two-dimensional (2D) mammography, 2D mammography plus digital breast tomosynthesis (DBT), and synthetic 2D mammography plus DBT in depicting malignant radiographic features. MATERIALS AND METHODS: In this multicenter, multireader, retrospective reading study (the TOMMY trial), after written informed consent was obtained, 8869 women (age range, 29-85 years; mean, 56 years) were recruited from July 2011 to March 2013 in an ethically approved study. From these women, a reading dataset of 7060 cases was randomly allocated for independent blinded review of (a) 2D mammography images, (b) 2D mammography plus DBT images, and (c) synthetic 2D mammography plus DBT images. Reviewers had no access to results of previous examinations. Overall sensitivities and specificities were calculated for younger women and those with dense breasts. RESULTS: Overall sensitivity was 87% for 2D mammography, 89% for 2D mammography plus DBT, and 88% for synthetic 2D mammography plus DBT. The addition of DBT was associated with a 34% increase in the odds of depicting cancer (odds ratio [OR] = 1.34, P = .06); however, this level did not achieve significance. For patients aged 50-59 years old, sensitivity was significantly higher (P = .01) for 2D mammography plus DBT than it was for 2D mammography. For those with breast density of 50% or more, sensitivity was 86% for 2D mammography compared with 93% for 2D mammography plus DBT (P = .03). Specificity was 57% for 2D mammography, 70% for 2D mammography plus DBT, and 72% for synthetic 2D mammography plusmDBT. Specificity was significantly higher than 2D mammography (P < .001in both cases) and was observed for all subgroups (P < .001 for all cases). CONCLUSION: The addition of DBT increased the sensitivity of 2D mammography in patients with dense breasts and the specificity of 2D mammography for all subgroups. The use of synthetic 2D DBT demonstrated performance similar to that of standard 2D mammography with DBT. DBT is of potential benefit to screening programs, particularly in younger women with dense breasts. (©) RSNA, 2015.The TOMMY Trial (a comparison of digital breast tomosynthesis with mammography in the UK Breast Screening Programme) was supported by the NIHR Health Technology Assessment Programme.This is the final published version of the article. It was originally published in Radiology (Gilbert et al., Radiology, 2015, doi:10.1148/radiol.2015142566). The final version is available at http://dx.doi.org/10.1148/radiol.201514256
- …