61 research outputs found

    Diagnóstico anatomopatológico, imuno-histoquímico e biomolecular de um caso de miocardite por Clostridium chauvoei em um bovino

    Get PDF
    The aim of this study was to report a case of clostridial myocarditis in a bovine in Brazil with emphasis on the pathological findings, isolation and molecular identification associated with the in situ localization of C. chauvoei. The animal, a male Brangus bull with nine months of age, was found dead without prior clinical signs. Multifocal and coalescent areas of necrosis were observed in the myocardium. Rod cells in the cardiac muscle fibers were positive immunostaining for C. chauvoei, while this bacterium was also isolated and identified by polymerase chain reaction (PCR).O objetivo deste estudo foi relatar um caso de miocardite clostridial em um bovino no Brasil, com ênfase nos achados patológicos, isolamento e identificação molecular do agente e visualização in situ de C. chauvoei. O animal, um macho da raça Brangus com nove meses de idade, foi encontrado morto sem sinais clínicos prévios. Foram observadas áreas de necrose multifocal e coalescente no miocárdio, com a presença de bastonetes imunomarcados para C. chauvoei nas fibras musculares cardíacas. Uma estirpe de C. chauvoei foi isolada do tecido e sua identidade foi confirmada por reação em cadeia da polimeras (PCR)

    Scavenging Activity on Reactive Oxygen Species with Biological Relevance by Varronia curassavica

    Get PDF
    Varronia curassavica Jacq. is a medicinal plant found in Brazil used as anti-inflammatory. Here, we investigated the in vitro antioxidant activity of 70 % ethanol extract of V. curassavica leaves on synthetic radicals (ABTS•+/DPPH•) and reactive oxygen species (O2•-, ROO•, HOCl/OCl-, H2O2), besides its in vitro cytotoxicity. The extract was characterized by UPLC-ESI-QToF-MSE and the annotated compounds were one hydroxybenzoic acid, five phenylpropanoids, and three glycosylated quercetin derivatives, being the main compound rosmarinic acid or its isomer. The antioxidant activity was very promising in all tests, highlighting on the capture of O2•-, which EC50 value was three times lower than Trolox. This activity may be due to the presence of the major compounds, all phenolic compounds. The extract also presented low cytotoxicity. Thus, the extract from V. curassavica leaves has great potential as an antioxidant

    Rapid responses of root traits and productivity to phosphorus and cation additions in a tropical lowland forest in Amazonia

    Get PDF
    • Soil nutrient availability can strongly affect root traits. In tropical forests, phosphorus (P) is often considered the main limiting nutrient for plants. However, support for the P paradigm is limited, and N and cations might also control tropical forests functioning. • We used a large‐scale experiment to determine how the factorial addition of nitrogen (N), P and cations affected root productivity and traits related to nutrient acquisition strategies (morphological traits, phosphatase activity, arbuscular mycorrhizal colonisation and nutrient contents) in a primary rainforest growing on low‐fertility soils in Central Amazonia after one year of fertilisation. • Multiple root traits and productivity were affected. Phosphorus additions increased annual root productivity and root diameter, but decreased root phosphatase activity. Cation additions increased root productivity at certain times of year, also increasing root diameter and mycorrhizal colonisation. P and cation additions increased their element concentrations in root tissues. No responses were detected with N addition. • Here we show that rock‐derived nutrients determine root functioning in low‐fertility Amazonian soils, demonstrating not only the hypothesised importance of P, but also highlighting the role of cations. The changes in fine root traits and productivity indicate that even slow‐growing tropical rainforests can respond rapidly to changes in resource availability

    Monitoramento pós-mercado dos testes rápidos para COVID-19: enfrentamento da pandemia:

    Get PDF
    Introduction: In December 2019, the  first group of patients with symptoms of atypical pneumonia was discovered in Wuhan, China. On January 7, 2020, the etiologic agent was identified; it was a new betacoronavirus, genetically similar to SARS-CoV-1, consisting of a simple RNA strand, an enveloped virus of 50-200nm in diameter, which was called SARS-CoV-2. Soon after, the disease was named COVID-19. On January 30, WHO declared a Public Health Emergency of International Importance due to the spread of the coronavirus. Tests for serological detection of IgM and IgG antibodies are those that provide an estimate of the immune response to SARS-CoV-2, highlighting the Rapid Diagnostic Tests (RDT), simple and accessible with a result within 5-30 minutes, based on sensitization of antigens/antibodies conjugated to colloidal gold capturing specific proteins present in the infected serum, plasma or blood. Objective: This work aims to show the analysis carried out with RDT for COVID-19 diagnosis in compliance with the current legislation from 02.04 to 18.08.2020. Method: In March of 2020, 25 serum/plasma samples were donated, without any identification. These samples were the remaining samples of tests performed on individuals with a confirmed diagnosis of SARS-CoV-2 infection by the RT-PCR technique from health services (National Institute of Infectious Diseases Evandro Chagas – INI and State Institute of the Brain Paulo Niemeyer – IEC) located in the metropolitan region of the state of Rio de Janeiro. The samples obtained in order to become a serological panel were stored at -20ºC until the moment of use. Simultaneously, a panel of samples with confirmed reactivity for IgM and IgG antibodies from COVID-19 was being made, throughout the pandemic and the samples used were evaluated against three Rapid Tests, of different antigenic compositions or different brands; two ELISA tests for IgM and IgG; two chemiluminescence tests and when applicable, a molecular test. In order to assess the specificity of the products sent, surplus donation plasma samples were selected, known to be negative for HIV, HTLV, hepatitis b and c, chagas and syphilis, collected between 2013 and 2014, in the southern regions of the country, period in which SARS-CoV-2 was nonexistent in the world. In addition to True Positive (VP) and True Negative (VN) samples, interfering serum or plasma samples with reactivity for HIV, HCV, HTLV, HBsAg, chagas disease, syphilis and dengue were also included in the evaluation. Results:  Out of 178 TR lots, 74.1%, 132 lots were from China and 25.9%, 46 TR lots were from Brazil; Germany; South Korea; Canada; USA; Singapore; Ireland and Switzerland. The analytical result showed that 57.0%, 101 TR lots obtained a Satisfactory result and 43%, 77 lots had Unsatisfactory results, when compared to the Sensitivity and Specificity values declared by the manufacturer, in the Instructions for Use. Conclusions:The results obtained show the need for constant monitoring of TRs for COVID-19 with the primary purpose of guaranteeing the quality of products sold in the country, one of the National Health Surveillance System pillars of action.  Introdução: Em dezembro de 2019, foi descoberto na cidade de Wuhan, China, um primeiro grupo de pacientes com sintomas de uma pneumonia atípica. Em 7 de janeiro de 2020, o seu agente etiológico foi identificado: tratava-se de um novo betacoronavírus, geneticamente similar ao SARS-CoV-1, constituído defita simples de RNA, vírus envelopado de 50-200 nm de diâmetro designado como SARS-CoV-2, e a doença foi denominada COVID-19. Em 30 de janeiro, a Organização Mundial da Saúde declarou Emergência de Saúde Pública de Importância Internacional em razão da disseminação desse novo vírus. Os testes para detecção sorológica de anticorpos IgM e IgG fornecem uma estimativa da resposta imune ao SARS-CoV-2, com destaque para os Testes Rápidos (TR) que são simples e acessíveis fornecendo resultados em 5-30 min. Esses testes são sensibilizados com antígenos/anticorpos conjugados ao ouro coloidal, capturando proteínas específicas presentes no soro, plasma ou sangue de pacientes infectados. Objetivo: Demonstrar a análise efetuada nos TR para diagnóstico da COVID-19, em atendimento a legislação vigente, no período de 2 de abril a 18 de agosto de 2020. Método: Durante o mês de março de 2020, foram cedidas 25 amostras de soro/plasma, sem qualquer identificação, excedentes dos testes efetuados em indivíduos com diagnóstico confirmado de infecção pelo SARS-CoV-2 pela técnica de RT-PCR provenientes de serviços de saúde (InstitutoNacional de Infectologia Evandro Chagas – INI e Instituto Estadual do Cérebro Paulo Niemeyer – IEC) localizados na região metropolitana do estado do Rio de Janeiro. As amostras obtidas para a confecção de painel sorológico foram armazenadas a -20ºC até o momento do uso. Concomitantemente, um painel de amostras com reatividade confirmada para anticorpos IgM e IgG da COVID-19 foi sendo confeccionado ao longo da pandemia e as amostras utilizadas foram avaliadas frente a três TR, de diferentes composições antigênicas ou diferentes marcas; dois testes ELISA para IgM e IgG; dois testes de quimioluminescência e quando aplicável, um teste molecular. Para avaliação da especificidade dos produtos encaminhados, foram selecionadas amostras de plasma excedentes de doação, sabidamente negativas para HIV, HTLV, hepatite B e C, doença de chagas e sífilis coletadas nos anos de 2013 e 2014, na Região Sul do país, período no qual o SARS-CoV-2 era inexistente. Além de amostras Verdadeiro Positivas (VP) e Verdadeiro Negativas (VN), ainda foram incluídas na avaliação amostras de soro ou plasma interferentes com reatividade para HIV, HCV, HTLV, HBsAg, doença de chagas, sífilis e dengue. Resultados:  Dos 178 lotes de TR, 74,1% foram provenientes da China e 25,9%, do Brasil, da Alemanha, da Coreia do Sul, do Canadá, dos EUA, da Cingapura,da Irlanda e da Suíça. O resultado analítico demonstrou que 57,0% dos TR obtiveram resultados satisfatórios e 43,0%, resultados insatisfatórios, quando comparados aos valores de sensibilidade e especificidade declarados pelo fabricante na instrução de uso. Conclusões: Há necessidade de constante monitoramento dos TR para COVID-19, com finalidade precípua de garantir a qualidade dos produtos comercializados no país, um dos pilares das ações do Sistema Nacional de Vigilância Sanitária
    corecore