25 research outputs found

    Relocation and seismotectonic interpretation of the seismic swarm of August – December of 2012 in the Linares area, northeastern Mexico

    Get PDF
    We relocated 52 events of 2.5 ≤ Mc ≤ 3.6 from a seismic sequence of over 250 events that occurred during July-December 2012 southwest of the Linares area, northeastern Mexico. To examine this swarm four seismic stations were installed in the region and operated during different time periods from September to December. Relocation of the swarm showed that the earthquake hypocentral depths were at 8 (±5) km, and the time residuals had values ≤ 0.38 s. The fault plane solutions were generated for individual earthquakes and through the use of the composite mechanism technique. The focal mechanism solutions show pure reverse faulting; the SW dipping NNW – SSE trending nodal plane is the inferred fault plane (strike ~150°, dip ~50° and rake ~67°), which reveals that maximum horizontal stress (SHmax > Shmin > Sv) predominates in the area. RESUMEN En este trabajo relocalizamos 52 sismos en el rango de 2.5 ≤ Mc ≤ 3.6 de una secuencia sísmica de más de 250 eventos que ocurrió al suroeste de la ciudad de Linares, N.L., durante los meses de julio – diciembre de 2012, en el noreste de México. Para estudiar este enjambre se instalaron cuatro estaciones sismológicas en la región de interés, las cuales operaron durante diferentes periodos entre septiembre y diciembre. La relocalización de la secuencia demostró que las profundidades hipocentrales fueron de 8 (±5) km, y los residuales de los tiempos de arribo tuvieron valores ≤ 0.38 s. Se generaron soluciones del plano de falla para sismos individuales, así como a través de la técnica de mecanismos compuestos. La solución de los mecanismos focales encontrada corresponde con fallamiento inverso con rumbo NNW-SSE y buzamiento hacia el SW para el plano nodal inferido (rumbo ~150°, buzamiento ~50° y ángulo de deslizamiento ~67°), el cual revela que el esfuerzo horizontal máximo predomina en el área de estudio (SHmax > Shmin > Sv)

    The evolution of the ventilatory ratio is a prognostic factor in mechanically ventilated COVID-19 ARDS patients

    Get PDF
    Background: Mortality due to COVID-19 is high, especially in patients requiring mechanical ventilation. The purpose of the study is to investigate associations between mortality and variables measured during the first three days of mechanical ventilation in patients with COVID-19 intubated at ICU admission. Methods: Multicenter, observational, cohort study includes consecutive patients with COVID-19 admitted to 44 Spanish ICUs between February 25 and July 31, 2020, who required intubation at ICU admission and mechanical ventilation for more than three days. We collected demographic and clinical data prior to admission; information about clinical evolution at days 1 and 3 of mechanical ventilation; and outcomes. Results: Of the 2,095 patients with COVID-19 admitted to the ICU, 1,118 (53.3%) were intubated at day 1 and remained under mechanical ventilation at day three. From days 1 to 3, PaO2/FiO2 increased from 115.6 [80.0-171.2] to 180.0 [135.4-227.9] mmHg and the ventilatory ratio from 1.73 [1.33-2.25] to 1.96 [1.61-2.40]. In-hospital mortality was 38.7%. A higher increase between ICU admission and day 3 in the ventilatory ratio (OR 1.04 [CI 1.01-1.07], p = 0.030) and creatinine levels (OR 1.05 [CI 1.01-1.09], p = 0.005) and a lower increase in platelet counts (OR 0.96 [CI 0.93-1.00], p = 0.037) were independently associated with a higher risk of death. No association between mortality and the PaO2/FiO2 variation was observed (OR 0.99 [CI 0.95 to 1.02], p = 0.47). Conclusions: Higher ventilatory ratio and its increase at day 3 is associated with mortality in patients with COVID-19 receiving mechanical ventilation at ICU admission. No association was found in the PaO2/FiO2 variation

    Canagliflozin and renal outcomes in type 2 diabetes and nephropathy

    Get PDF
    BACKGROUND Type 2 diabetes mellitus is the leading cause of kidney failure worldwide, but few effective long-term treatments are available. In cardiovascular trials of inhibitors of sodium–glucose cotransporter 2 (SGLT2), exploratory results have suggested that such drugs may improve renal outcomes in patients with type 2 diabetes. METHODS In this double-blind, randomized trial, we assigned patients with type 2 diabetes and albuminuric chronic kidney disease to receive canagliflozin, an oral SGLT2 inhibitor, at a dose of 100 mg daily or placebo. All the patients had an estimated glomerular filtration rate (GFR) of 30 to <90 ml per minute per 1.73 m2 of body-surface area and albuminuria (ratio of albumin [mg] to creatinine [g], >300 to 5000) and were treated with renin–angiotensin system blockade. The primary outcome was a composite of end-stage kidney disease (dialysis, transplantation, or a sustained estimated GFR of <15 ml per minute per 1.73 m2), a doubling of the serum creatinine level, or death from renal or cardiovascular causes. Prespecified secondary outcomes were tested hierarchically. RESULTS The trial was stopped early after a planned interim analysis on the recommendation of the data and safety monitoring committee. At that time, 4401 patients had undergone randomization, with a median follow-up of 2.62 years. The relative risk of the primary outcome was 30% lower in the canagliflozin group than in the placebo group, with event rates of 43.2 and 61.2 per 1000 patient-years, respectively (hazard ratio, 0.70; 95% confidence interval [CI], 0.59 to 0.82; P=0.00001). The relative risk of the renal-specific composite of end-stage kidney disease, a doubling of the creatinine level, or death from renal causes was lower by 34% (hazard ratio, 0.66; 95% CI, 0.53 to 0.81; P<0.001), and the relative risk of end-stage kidney disease was lower by 32% (hazard ratio, 0.68; 95% CI, 0.54 to 0.86; P=0.002). The canagliflozin group also had a lower risk of cardiovascular death, myocardial infarction, or stroke (hazard ratio, 0.80; 95% CI, 0.67 to 0.95; P=0.01) and hospitalization for heart failure (hazard ratio, 0.61; 95% CI, 0.47 to 0.80; P<0.001). There were no significant differences in rates of amputation or fracture. CONCLUSIONS In patients with type 2 diabetes and kidney disease, the risk of kidney failure and cardiovascular events was lower in the canagliflozin group than in the placebo group at a median follow-up of 2.62 years

    Cinna Lomnitz in his own words

    No full text
    ¿Cuántas personas habrían tenido la desgracia de estar presentes cerca del epicentro del terremoto más grande de la historia y también del sismo más destructivo jamás ocurrido en México? Ciertamente no mucha gente, pero menos aún son los que dedican su vida a la sismología

    Carta de los Editores

    Get PDF
    Cerca de la medianoche del 7 de septiembre de 2017 (08/09/2017, 04:49:17 UTC) ocurrió uno de los sismos más grandes registrados instrumentalmente en México. La magnitud estimada (Mw=8.2) es solo comparable con el sismo de 1932 ocurrido en las costas de Jalisco y Colima. doi: https://doi.org/10.22201/igeof.00167169p.2020.59.2.208

    Carta de los Editores

    Get PDF
    Cerca de la medianoche del 7 de septiembre de 2017 (08/09/2017, 04:49:17 UTC) ocurrió uno de los sismos más grandes registrados instrumentalmente en México. La magnitud estimada (Mw=8.2) es solo comparable con el sismo de 1932 ocurrido en las costas de Jalisco y Colima. doi: https://doi.org/10.22201/igeof.00167169p.2020.59.3.211

    Apilado de funciones de auto-correlación de ruido sísmico para obtener la profundidad del moho

    No full text
    Actualmente las aplicaciones del uso del ruido sísmico van desde el monitoreo local de campos geotérmicos y volcánicos, hasta tomografías a gran escala. Una de las aplicaciones es la determinación de los tiempos de arribo asociados a las reflexiones justo debajo de la estación con cada discontinuidad en el medio. Para esto es necesario calcular la función de auto-correlación (FAC) de series de tiempo de ruido sísmico de larga duración y apilarlas. De esta manera se logra resaltar señales coherentes contenidas en el ruido que son interpretadas como las reflexiones en los diferentes estratos. En este trabajo se presenta una metodología para determinar el tiempo de estas reflexiones. El método consiste en definir un espectro de frecuencias de interés, que estará en función de la discontinuidad que se quiera encontrar. Después se debe discretizar el espectro en un número finito de frecuencias centrales con un ancho de banda. Para cada frecuencia central se deben filtrar los datos de ruido sísmico. Teniendo esto se calculan las FAC y se apilan en series de 1 día. El siguiente paso es realizar correlogramas para cada filtro y todos los días en busca de la reflexión de interés y seleccionar aquellas frecuencias centrales donde es visible, así como los días donde los datos tienen resolución. Por último se toman las FAC de las frecuencias y días de interés y se hace un apilado por día de todas las frecuencias y al final un apilado de todos los días. El resultado es una FAC que muestra la reflexión buscada. Para probar el método, se diseñó una estrategia para modelar el ruido registrado en una estación sobre un modelo de velocidades 1D. Dado que se conoce el modelo es posible determinar el tiempo de arribo para las diferentes discontinuidades, de manera que al aplicar el método descrito los tiempos de arribo coincidían. Finalmente, aplicamos la misma metodología al arreglo de estaciones MASE y contrastamos los resultados con los obtenidos por otros autores

    A source study of the October, 2007 earthquake sequence of Morelia, Mexico and ground-motion estimation from larger earthquakes in the region

    Get PDF
    En este artículo se analiza una secuencia de siete sismos (2.5<Mw<3.0) ocurridos en la Ciudad de Morelia, México. Esta serie de temblores ocurrieron en un intervalo de 33 horas en el mes de octubre de 2007. Fueron registrados por dos estaciones locales ubicadas en esa Ciudad. Morelia se encuentra en la la parte central de la Faja Volcánica Trans-Mexicana (CTMVB, por sus siglas en inglés). Las formas de onda y los espectros de estos sismos son sorprendentemente similares, sugiriendo que sus localizaciones y mecanismos focales son casi idénticos. La inversión de forma de onda, restringida a partir de fallas descritas anteriormente en el área (rumbo ~E-O, buzando al norte), arroja un mecanismo focal definido por =2650, =750 y = -300, lo cual es consistente con los mecanismos focales reportados previamente en la región. Dado que, para estos pequeños eventos, la señal se confunde con el ruido para frecuencias f<0.2Hz, se estimó el momento sísmico M0 a partir del espectro de las ondas S en una banda de frecuencias definida en el intervalo 0.2≤f≤1Hz. Sin embargo, en esta banda de frecuencias, existe una amplificación significativa de las ondas símicas debida a una capa de baja velocidad provocada por rocas volcánicas superficiales presentes en cualquier sitio localizado en el CTMVB. En la estimación del M0 y en la interpretación de los espectros observados, se aproximó esta amplificación usando el cociente espectral H/Z. Asumiendo un modelo de fuente 2, los espectros observados pueden ser explicados con ternas (Δσ, t*, fm) (5MPa, 0.02s, 20Hz) y (20 MPa, 0.03 s, 20 Hz), donde Δσ es la caída de esfuerzos asumiendo el modelo de Brune y t* y fm son los parámetros de atenuación. Con el fin de simular el movimiento fuerte del terreno, para un sismo postulado de Mw5, se usaron estas combinaciones de parámetros junto con las técnicas de Empirical Green Function (EGF) y Random Vibration Theory (RVT). Las aceleraciones horizontales PGA y velocidades PGV en los sitios de referencia están en el rango de 23 a 46 cm/s2 y de 1.5 a 3.52 cm/s para una caída de esfuerzos de Δσ=5Mpa. Los valores pronosticados para una caída de esfuerzos Δσ=20Mpa son casi el doble (44-89 cm/s2 and 2.5-6.1 cm/s). Las estimaciones obtenidas, especialmente para Δσ=5MPa, son considerablemente más pequeñas que las reportadas a partir de datos globales. Esta comparación sugiere que existe una alta atenuación en la región volcánica o una inadecuada estimación del efecto de t* y fm. doi: https://doi.org/10.22201/igeof.00167169p.2012.51.1.14

    Estimation of source, path and site effects at MASE array stations: a comprehensive study

    Get PDF
    En este trabajo se presenta una técnica de inversión parametrizada de los efectos de la fuente y el trayecto, basada en el empleo de métodos de optimización global. Se aplica esta técnica a los datos de velocidad correspondientes a varios eventos sísmicos registrados entre agosto de 2005 y abril de 2007 en México, por la red sísmica regional MASE (Meso American Subduction Experiment) así como por otras estaciones pertenecientes a la red permanente del Servicio Sismológico Nacional (SSN). Los parámetros de la fuente, el trayecto y el efecto de sitio, correspondientes a los espectros de amplitud para ondas S de 219 registros sísmicos de velocidad (162 pertenecientes a la red MASE y 57 a la red SSN), fueron estimados por medio de este esquema de inversión generalizada. Los parámetros invertidos simultáneamente a partir de los registros de 55 estaciones muestran un acuerdo significativo entre los espectros observados y calculados, lo cual apoya la confiabilidad de tales estimaciones. Se empleó la técnica de Nakamura para calcular una estimación inicial para la inversión generalizada. Se establecieron comparaciones entre la técnica de Nakamura y la inversión parametrizada de los efectos de la fuente y el trayecto, utilizando el método de simulated annealing. Finalmente, se calculó una nueva relación de atenuación dependiente de la frecuencia para el área de estudio, empleando un esquema de inversión basado en algoritmos genéticos. doi: https://doi.org/10.22201/igeof.00167169p.2017.56.1.174
    corecore