14 research outputs found

    Double sampling of a faecal immunochemical test is not superior to single sampling for detection of colorectal neoplasia: a colonoscopy controlled prospective cohort study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A single sampled faecal immunochemical test (FIT) has moderate sensitivity for colorectal cancer and advanced adenomas. Repeated FIT sampling could improve test sensitivity. The aim of the present study is to determine whether any of three different strategies of double FIT sampling has a better combination of sensitivity and specificity than single FIT sampling.</p> <p>Methods</p> <p>Test performance of single FIT sampling in subjects scheduled for colonoscopy was compared to double FIT sampling intra-individually. Test positivity of double FIT sampling was evaluated in three different ways: 1) "one of two FITs+" when at least one out of two measurements exceeded the cut-off value, 2) "two of two FITs+" when both measurements exceeded the cut-off value, 3) "mean of two FITs+" when the geometric mean of two FITs exceeded the cut-off value. Receiver operator curves were calculated and sensitivity of single and the three strategies of double FIT sampling were compared at a fixed level of specificity.</p> <p>Results</p> <p>In 124 of 1096 subjects, screen relevant neoplasia (SRN) were found (i.e. early stage CRC or advanced adenomas). At any cut-off, "two of two FITs+" resulted in the lowest and "one of two FITs+" in the highest sensitivity for SRN (range 35-44% and 42%-54% respectively). ROC's of double FIT sampling were similar to single FIT sampling. At specificities of 85/90/95%, sensitivity of any double FIT sampling strategy did not differ significantly from single FIT (p-values 0.07-1).</p> <p>Conclusion</p> <p>At any cut off, "one of two FITs+" is the most sensitive double FIT sampling strategy. However, at a given specificity level, sensitivity of any double FIT sampling strategy for SRN is comparable to single FIT sampling at a different cut-off value. None of the double FIT strategies has a superior combination of sensitivity and specificity over single FIT.</p

    Decision making as a predictor of first ecstasy use: a prospective study

    Get PDF
    Ecstasy (+/- 3,4-methylenedioxymethamphetamine) is a widely used recreational drug that may damage the serotonin system and may entail neuropsychological dysfunctions. Few studies investigated predictors for ecstasy use. Self-reported impulsivity does not predict the initiation of ecstasy use; the question is if neuropsychological indicators of impulsivity can predict first ecstasy use. This study tested the hypothesis that a neuropsychological indicator of impulsivity predicts initiation of ecstasy use. Decision-making strategy and decision-making reaction times were examined with the Iowa Gambling Task in 149 ecstasy-naive subjects. The performance of 59 subjects who initiated ecstasy use during a mean follow-up period of 18 months (range, 11-26) was compared with the performance of 90 subjects that remained ecstasy-naive. Significant differences in decision-making strategy between female future ecstasy users and female persistent ecstasy-naive subjects were found. In addition, the gap between decision-making reaction time after advantageous choices and reaction time after disadvantageous choices was smaller in future ecstasy users than in persistent ecstasy-naives. Decision-making strategy on a gambling task was predictive for future use of ecstasy in female subjects. Differences in decision-making time between future ecstasy users and persistent ecstasy-naives may point to lower punishment sensitivity or higher impulsivity in future ecstasy users. Because differences were small, the clinical relevance is questionabl

    Home care in Europe: a systematic literature review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Health and social services provided at home are becoming increasingly important. Hence, there is a need for information on home care in Europe. The objective of this literature review was to respond to this need by systematically describing what has been reported on home care in Europe in the scientific literature over the past decade.</p> <p>Methods</p> <p>A systematic literature search was performed for papers on home care published in English, using the following data bases: Cinahl, the Cochrane Library, Embase, Medline, PsycINFO, Sociological Abstracts, Social Services Abstracts, and Social Care Online. Studies were only included if they complied with the definition of home care, were published between January 1998 and October 2009, and dealt with at least one of the 31 specified countries. Clinical interventions, instrument developments, local projects and reviews were excluded. The data extracted included: the characteristics of the study and aspects of home care 'policy & regulation', 'financing', 'organisation & service delivery', and 'clients & informal carers'.</p> <p>Results</p> <p>Seventy-four out of 5,133 potentially relevant studies met the inclusion criteria, providing information on 18 countries. Many focused on the characteristics of home care recipients and on the organisation of home care. Geographical inequalities, market forces, quality and integration of services were also among the issues frequently discussed.</p> <p>Conclusions</p> <p>Home care systems appeared to differ both between and within countries. The papers included, however, provided only a limited picture of home care. Many studies only focused on one aspect of the home care system and international comparative studies were rare. Furthermore, little information emerged on home care financing and on home care in general in Eastern Europe. This review clearly shows the need for more scientific publications on home care, especially studies comparing countries. A comprehensive and more complete insight into the state of home care in Europe requires the gathering of information using a uniform framework and methodology.</p

    Faecal immunochemical test accuracy in patients referred for surveillance colonoscopy: a multi-centre cohort study

    No full text
    Abstract Background Given the increasing burden on colonoscopy capacity, it has been suggested that faecal immunochemical test (FIT) results could guide surveillance colonoscopy intervals. Against this background, we have evaluated the test accuracy of single and double FIT sampling to detect colorectal cancer (CRC) and/or advanced adenomas in an asymptomatic colonoscopy-controlled high-risk population. Methods Cohort study of asymptomatic high-risk patients (personal history of adenomas/CRC or family history of CRC), who provided one or two FITs before elective colonoscopy. Test accuracy of FIT for detection of CRC and advanced adenomas was determined (cut-off level 50 ng/ml). Results 1,041 patients provided a FIT (516 personal history of adenomas, 172 personal history of CRC and 353 family history of CRC). Five CRCs (0.5%) and 101 advanced adenomas (9.7%) were detected by colonoscopy. Single FIT sampling resulted in a sensitivity, specificity, PPV and NPV for CRC of 80%, 89%, 3% and 99.9%, respectively, and for advanced adenoma of 28%, 91%, 24% and 92%, respectively. Double FIT sampling did not result in a significantly higher sensitivity for advanced neoplasia. Simulation of multiple screening rounds indicated that sensitivity of FIT for advanced adenoma could reach 81% after 5 screening rounds. Conclusions In once-only FIT sampling before surveillance colonoscopy, 70% of advanced neoplasia were missed. A simulation approach indicates that multiple screening rounds may be more promising in detecting advanced neoplasia and could potentially alleviate endoscopic burden.</p
    corecore