    State diagrams of the heart – a new approach to describing cardiac mechanics

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cardiac time intervals have been described as a measure of cardiac performance, where prolongation, shortening and delay of the different time intervals have been evaluated as markers of cardiac dysfunction. A relatively recently developed method with improved ability to measure cardiac events is Tissue Doppler Imaging (TDI), allowing accurate measurement of myocardial movements.</p> <p>Methods</p> <p>We propose the state diagram of the heart as a new visualization tool for cardiac time intervals, presenting comparative, normalized data of systolic and diastolic performance, providing a more complete overview of cardiac function. This study aimed to test the feasibility of the state diagram method by presenting examples demonstrating its potential use in the clinical setting and by performing a clinical study, which included a comparison of the state diagram method with established echocardiography methods (E/E' ratio, LVEF and WMSI). The population in the clinical study consisted of seven patients with non ST-elevation myocardial infarction (NSTEMI) and seven control subjects, individually matched according to age and gender. The state diagram of the heart was generated from TDI curves from seven positions in the myocardium, visualizing the inter- and intraventricular function of the heart by displaying the cardiac phases.</p> <p>Results</p> <p>The clinical examples demonstrated that the state diagram allows for an intuitive visualization of pathological patterns as ischemia and dyssynchrony. Further, significant differences in percentage duration between the control group and the NSTEMI group were found in eight of the totally twenty phases (10 phases for each ventricle), e.g. in the transition phases (Pre-Ejection and Post-Ejection). These phases were significantly longer (> 2.18%) for the NSTEMI group than for the control group (p < 0.05). No significant differences between the groups were found for the established echocardiography methods.</p> <p>Conclusion</p> <p>The test results clearly indicate that the state diagram has potential to be an efficient tool for visualization of cardiac dysfunction and for detection of NSTEMI.</p

    New ultrasonographic approaches to monitoring cardiac and vascular function

    No full text
    Atherosclerotic cardiovascular disease is the leading cause of death worldwide. To decrease mortality and morbidity in cardiovascular disease, the development of accurate, non-invasive methods for early diagnosis of atherosclerotic cardiac and vascular engagement is of considerable clinical interest. Cardiovascular ultrasound imaging is today the cornerstone in the routine evaluation of cardiovascular function and recent development has resulted in two new techniques, tissue velocity imaging (TVI) and speckle tracking, which allow objective quantification of cardiovascular function. TVI and speckle tracking are the basis for three new approaches to cardiac and vascular monitoring presented in this thesis: wave intensity wall analysis (WIWA), two-dimensional strain imaging in the common carotid artery, and the state diagram of the heart.   WIWA uses longitudinal and radial strain rate as input for calculations of wave intensity in the arterial wall. In this thesis, WIWA was validated against a commercially available wave intensity system, showing that speckle tracking-derived strain variables can be useful in wave intensity analysis. WIWA was further tested in patients with end stage renal disease and documented high mortality in cardiovascular disease. The latter study evaluated the effects of a single session of hemodialysis using WIWA and TVI variables and showed improved systolic function after hemodialysis. The results also indicated that preload-adjusted early systolic wave intensity obtained by the WIWA system may contribute in the assessment of left ventricular contractility in this patient category. Two-dimensional strain imaging in the common carotid artery is a new approach showing great potential to detect age-dependent differences in mechanical properties of the common carotid artery. Among the measured strain variables, global circumferential strain had the best discriminating performance and appeared to be superior to conventional measures of arterial stiffness such as elastic modulus and β stiffness index. The state diagram is a visualisation tool that provides a quantitative overview of the temporal interrelationship of mechanical events in the left and right ventricles. Case examples and a small clinical study showed that state diagrams clearly visualize cardiac function and can be useful in the detection of non ST-elevation myocardial infarction (NSTEMI).   Even though WIWA, two-dimensional strain imaging in the common carotid artery and the state diagram show potential to be useful in the evaluation of cardiovascular function, there still remains a considerable amount of work to be done before they can be used in the daily clinical practice.QC 20100705</p

    Paper Title (use style: paper title)

    No full text
    Abstract-There are advantages of using a polymeric shelled contrast agent (CA) during ultrasound imaging instead of lipid shelled CA, e.g. particles can be attached to the surface, which enables an introduction of antibodies to the surface making the CA target specific. For this application it is essential to have a sensitive imaging technique suitable for polymeric CA. However, previously presented results have indicated difficulties in visualizing polymeric CA with commercially available contrast algorithms. Therefore a new subtraction algorithm (SA), was developed that define the difference between contrast and reference images. The aim of this study was to evaluate the response from a polymeric CA, when using the SA and compare it with existing contrast algorithms. Moreover, the possibility to detect a thin layer of CA was tested using the SA. Ultrasound short-axis images of a tissue-mimicking vessel phantom with a pulsating flow were obtained using a GE Vivid7 system (M12L) and a Philips iE33 system (S5-1). Repeated (n=91) contrast to tissue ratios (CTR) calculated at various mechanical index (MI) using the contrast algorithms pulse inversion (PI), power modulatio

    A new ultrasound-based approach to visualize target specific polymeric contrast agent

    No full text
    There are advantages of using a polymeric shelled contrast agent (CA) during ultrasound imaging instead of lipid shelled CA, e.g. particles can be attached to the surface, which enables an introduction of antibodies to the surface making the CA target specific. For this application it is essential to have a sensitive imaging technique suitable for polymeric CA. However, previously presented results have indicated difficulties in visualizing polymeric CA with commercially available contrast algorithms. Therefore a new subtraction algorithm (SA), was developed that define the difference between contrast and reference images. The aim of this study was to evaluate the response from a polymeric CA, when using the SA and compare it with existing contrast algorithms. Moreover, the possibility to detect a thin layer of CA was tested using the SA. Ultrasound short-axis images of a tissue-mimicking vessel phantom with a pulsating flow were obtained using a GE Vivid7 system (M12L) and a Philips iE33 system (S5-1). Repeated (n=91) contrast to tissue ratios (CTR) calculated at various mechanical index (MI) using the contrast algorithms pulse inversion (PI), power modulation (PM) and SA at a concentration of 105microbubbles/ml. The developed SA showed improvements in CTR compared to existing contrast algorithms. The CTRs were -0.99 dB ± 0.67 (MI 0.2), 9.46 dB ± 0.77 (MI 0.4) and 2.98 dB ± 0.60 (MI 0.8) with PI, 8.17 dB ± 1.15 (MI 0.2), 15.60 dB ± 1.29 (MI0.4) and 11.60 dB ± 0.73 (MI 0.8) with PM and 14.97 dB ± 3.97 (MI 0.2), 20.89 dB ± 3.54 (MI 0.4) and 21.93 dB ± 4.37 (MI 0.8) with the SA. In addition to this, the layer detection, when using the SA was successful.© 2011 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.</p

    Shear wave elastography of the arterial wall : Where are we today

    No full text
    1. Introduction Shear Wave Elastography (SWE) is a recently developed noninvasive method for elastography assessment using ultrasound. The technique consists of sending an acoustic radiation force (pushing sequence) into the tissue that in turn generates an orthogonal low frequency propagating shear wave. The shear wave propagation is measured real time by high speed B-mode imaging. From the B-mode images, the shear wave is tracked via normalized cross-correlation and the speed is calculated, which is used to generate an elasticity map of the tissue’s shear modulus. To date, the technique has mostly been used in large homogeneous tissues such as breast and liver where it successfully detects lesions and tumors that are easily missed with normal B-mode ultrasound [1]. SWE could potentially be applied in vascular applications to assess elasticity of the arterial wall to characterize the stiffness as an early indicator of cardiac disease. Furthermore, SWE could aid in the characterization of plaques in the carotid artery, which is critical for the prevention of ischemic stroke 2. Methods and Results An initial study was performed using an Aixplorer SWE system (Supersonic Imagine, France) to measure the shear modulus in a polyvinyl alcohol phantom (PVA) vessel with a plaque inclusion (Figure 1). It was possible to distinguish the softer inclusion mean shear wave speed (2.1 m/s) from the arterial wall (3.5 m/s) on the SWE colour-map, but the Young’s Modulus calculation of the arterial wall (E=19.8 kPa) did not match the measured Young’s Modulus (E=53.1 kPa) from comparative mechanical testing.&lt;/p&gt;&lt;p&gt;We have begun implementing various pushing sequences (single unfocused push, single focused push, line push, comb push) on a programmable ultrasound machine (Verasonics, USA) using a linear transducer (Philips L7-4) in a homogeneous PVA phantom. An algorithm for one dimensional cross-correlation tracking and shear wave speed estimation has been developed and initially tested in an experimental setup 3. Discussion According to our initial results, it is possible that SWE could be applied in vascular applications. However, the initial mechanical testing vs. SWE comparison indicated that further development to the post processing is needed before applying it on the carotid artery, which is a heterogeneous tissue with other wave propagation properties than e.g. breast tissue. The carotid artery has a difficult geometry to study for several reasons. The intima-media complex is very thin (&amp;lt; 1mm), and the vessel wall is not stationary. Furthermore, the cylindrical shape of the artery produces complex wave reflections within the arterial wall, which result in a polychromatic propagation of the shear wave. A few studies have applied techniques based on SWE to the arterial wall with promising results and a pilot study demonstrating the feasibility of the technique in-vivo has been published [2]. Still, a considerable effort is needed to validate and optimize the technique for the clinical vascular setting