10 research outputs found

    An experimental study to compare the interface pressure and experience of healthy participants when lying still for 20 minutes in a supine position on two different imaging surfaces

    Get PDF
    Introduction: Pressure ulcers are a high cost, high volume issue for health and medical care providers, affecting patients’ recovery and psychological wellbeing. The current research of support surfaces on pressure as a risk factor in the development of pressure ulcers is not relevant to the specialised, controlled environment of the radiological setting. Method: 38 healthy participants aged 19-51 were placed supine on two different imaging surfaces. The XSENSOR pressure mapping system was used to measure the interface pressure. Data was acquired over a time of 20 minutes preceded by 6 minutes settling time to reduce measurement error. Qualitative information regarding participants’ opinion on pain and comfort was recorded using a questionnaire. Data analysis was performed using SPSS 22. Results: Data was collected from 30 participants aged 19 to 51 (mean 25.77, SD 7.72), BMI from 18.7 to 33.6 (mean 24.12, SD 3.29), for two surfaces, following eight participant exclusions due to technical faults. Total average pressure, average pressure for jeopardy areas (head, sacrum & heels) and peak pressure for jeopardy areas were calculated as interface pressure in mmHg. Qualitative data showed that a significant difference in experiences of comfort and pain was found in the jeopardy areas (P<0.05) between the two surfaces. Conclusion: A significant difference is seen in average pressure between the two surfaces. Pain and comfort data also show a significant difference between the surfaces, both findings support the proposal for further investigation into the effects of radiological surfaces as a risk factor for the formation of pressure ulcers

    An experimental intervention study assessing the impact of a thin silicone gel surface overlay on interface pressure

    Get PDF
    Introduction. The incidence of pressure ulcers (PUs) presents a substantial threat to patients, especially geriatric patients, those with restricted mobility, and patients suffering from chronic diseases such as cancer. PUs creates a huge financial burden on healthcare authorities and patients, costing billions to treat and manage. Radiography and radiotherapy patients may experience medical device related (MDR) PUs and studies have shown that high interface pressure (IP) values exist for the head when placed on an X-ray table without a mattress. These high IP values pose a PU risk to patients, especially those accessing prolonged radiography/radiology and radiotherapy procedures. The current study assessed the impact on IP values for the head from using a thin silicone gel surface overlay during radiographic procedures and identified whether this reduced the risk of PUs. Materials and Methods. A calibrated XSENSOR pressure mat was used to measure IP for the head on an X-ray table with and without a thin silicone gel surface overlay. Prior to pressure mapping, the silicone gel surface overlay was assessed for its impact on radiation attenuation and image quality. Results. Study participants were 14 males (70%) and six females (30%), with an age range of 25–53 years (mean = 34.4 ± 7.0). Paired-samples t-test results indicated that there was a statistically significant decrease in the mean IP for the head on the X-ray table without the silicone gel surface overlay (mean = 83.9 ± 8.2 in mmHg) and the X-ray table with the gel surface overlay (mean = 62.4 ± 6.1 in mmHg), p ≤ 0.001 . Paired-samples t-test results indicated that there was a statistically significant decrease in the mean peak pressure index (PPI) for the head on the X-ray table without the silicone gel surface overlay (mean = 205.1 ± 28.2 in mmHg) and the X-ray table with the gel surface overlay (mean = 159.8 ± 26.8 in mmHg), p ≤ 0.001 . Conclusions. The use of a thin silicone gel surface overlay could reduce IP risk for the head by approximately 25%. The reduction in IP risk could have a significant impact in reducing the risk of developing a PU. To ensure maximum benefit, the silicone gel surface overlay should be evaluated to address the specific needs within radiography and radiotherapy planning and treatment settings

    Review article – The effects of clinical support surfaces on pressure as a risk factor in the development of pressure ulcers, from a radiographical perspective: a narrative literature review

    Get PDF
    Purpose: Pressure ulcers are a high cost, high volume issue for health and medical care providers, having a detrimental effect on patients and relatives. Pressure ulcer prevention is widely covered in the literature, but little has been published regarding the risk to patients in the radiographical setting. This review of the current literature is to identify findings relevant to radiographical context. Methods: Literature searching was performed using Science Direct and Medline databases. The search was limited to articles published in the last ten years to remain current and excluded studies containing participants less than 17 years of age. In total 14 studies were acquired; three were excluded as they were not relevant. The remaining 11 studies were compared and reviewed. Discussion: Eight of the studies used ‘healthy’ participants and three used symptomatic participants. Nine studies explored interface pressure with a range of pressure mat technologies, two studies measured shear (MRI finite element modelling, and a non-invasive instrument), and one looked at blood flow and haemoglobin oxygenation. A range of surfaces were considered from trauma, nursing and surgical backgrounds for their ability to reduce pressure including standard mattresses, high specification mattresses, rigid and soft layer spine boards, various overlays (gel, air filled, foam). Conclusion: The current literature is not appropriate for the radiographic patient and cannot be extrapolated to a radiologic context. Sufficient evidence is presented in this review to support the need for further work specific to radiography in order to minimise the development of PU in at risk patients

    The effects of clinical support surfaces on pressure as a risk factor in the development of pressure ulcers, from a radiographical perspective: a narrative literature review

    Get PDF
    Purpose: Pressure ulcers are a high cost, high volume issue for health and medical care providers, having a detrimental effect on patients and relatives. Pressure ulcer prevention is widely covered in the literature, but little has been published regarding the risk to patients in the radiographical setting. This review of the current literature is to identify findings relevant to radiographical context. Methods: Literature searching was performed using Science Direct and Medline databases. The search was limited to articles published in the last ten years to remain current and excluded studies containing participants less than 17 years of age. In total 14 studies were acquired; three were excluded as they were not relevant. The remaining 11 studies were compared and reviewed. Discussion: Eight of the studies used ‘healthy’ participants and three used symptomatic participants. Nine studies explored interface pressure with a range of pressure mat technologies, two studies measured shear (MRI finite element modelling, and a non-invasive instrument), and one looked at blood flow and haemoglobin oxygenation. A range of surfaces were considered from trauma, nursing and surgical backgrounds for their ability to reduce pressure including standard mattresses, high specification mattresses, rigid and soft layer spine boards, various overlays (gel, air filled, foam). Conclusion: The current literature is not appropriate for the radiographic patient and cannot be extrapolated to a radiologic context. Sufficient evidence is presented in this review to support the need for further work specific to radiography in order to minimise the development of PU in at risk patients

    Compression force variability in mammography in Ghana – a baseline study

    Get PDF
    Introduction: Breast compression during mammographic examinations improves image quality and patient management. Several studies have been conducted to assess compression force variability among practitioners in order to establish compression guidelines. However, no such study has been conducted in Ghana. This study aims to investigate the compression force variability in mammography in Ghana. Methods: This retrospective study used data gathered from 1071 screening and diagnostic mammography patients from January, 2018–December, 2019. Data were gathered by seven radiographers at three centers. Compression force, breast thickness and practitioners' years of work experience were recorded. Compression force variability among practitioners and the correlation between compression force and breast thickness were investigated. Results: Mean compression force values recorded for craniocaudal (CC) (17.2 daN) and mediolateral oblique (MLO) (18.2 daN), were within the recommended values used by western countries. Most of the mammograms performed – 80% – were within the National Health Service Breast Screening Programme (NHSBSP) range. However, 65% were above the Norwegian Breast Cancer Screening Programme (NBCSP) range. Compression forces varied significantly (p = 0.0001) among practitioners. Compression forces increased significantly (p = 0.0001) with the years of work experience. A weak negative correlation (r = −0.144) and a weak positive correlation (r = 0.142) were established between compression force and breast thickness for CC and MLO projections respectively. Conclusion: This initial study confirmed that although wide variations in compression force exist among practitioners in Ghana, most practitioners used compression forces broadly within the range set by the NHSBSP. As no national guidelines for compression force currently exist in Ghana, provision of these may help to reduce the range of variations recorded. Implications for practice: Confirmation of variations in compression will guide future practice to minimize image quality disparities and improve quality of care

    A narrative review on pressure ulcer (PU) studies relevant to medical imaging

    Get PDF
    Pressure ulcers (PUs) are defined as localised injuries to the skin and/or underlying tissue as a result of pressure or pressure together with shear. PUs present significant health implications to patients; costing billions to manage and/or treat. The burden of PU prevention in hospitals must be the concern of all healthcare professionals, including radiographers. The purpose of this narrative review article is to identify and critically evaluate relevant literature and research conducted into pressure ulcers (PUs) relevant to medical imaging. It is expected that this review article will increase the level of awareness about PUs amongst radiographers and help to develop appropriate interventions to minimise the risk of PUs. A literature search was conducted in PubMed/Medline, Scopus, CINAHL, and Google Scholar to retrieve relevant articles. Also, books, professional body guidelines, magazines, grey and unpublished literatures were also searched. The search was limited to English Language articles. Only five articles were retrieved and reviewed. There are limited studies on PUs relevant to medical imaging. Available studies provide some evidence that radiographic procedures and settings subject patients attending for radiographic procedures to the risk of PUs. Further studies are needed into PU risk assessment, minimisation and management in medical imaging to help raise awareness and address the problem of the potential for PU development
    corecore