37 research outputs found

    Evaluation of skin temperature, reactive C protein, and hemosedimentation speed variation in uncomplicated primary knee total arthroplasty

    Get PDF
    OBJECTIVE: To study the variation of skin temperature values (deltaT) on operative site, of reactive C protein (RCP) and of hemosedimentation speed (HSS) in patients submitted to primary knee total arthroplasty (KTA), in an attempt to establish a correlation among its curves over time. MATERIALS AND METHODS: This prospective clinical study evaluated 29 patients followed up during 12 weeks, with measurements of skin temperature in both knees and RCP and HSS serum dosages. RESULTS: After comparing the variables tested (deltaT, RCP and HSS), no statistical correlation was observed for both the Pearson s test (parametric test) and the Spearman s test (non-parametric test) among variables. Skin temperature variation follows a different pattern from that observed both for RCP and for HSS, with no correlation among curves. A standard curve was established for the three variables, and a statistically significant reduction was seen in RCP and HSS values from pre- to post-operative period. CONCLUSION: No correlation was observed between skin temperature and HSS and RCP levels in patients submitted to uncomplicated primary KTA.OBJETIVO: Estudar a variação dos valores da temperatura cutânea (deltaT) do sítio operatório, da proteína C reativa (PCR) e da velocidade de hemossedimentação (VHS) em pacientes submetidos a artroplastia total do joelho (ATJ) primária, tentando estabelecer correlação entre suas curvas ao longo do tempo. MATERIAL E MÉTODOS: Esse estudo clínico prospectivo, avaliou 29 pacientes acompanhados por 12 semanas, sendo aferida a temperatura cutânea em ambos os joelhos e realizada dosagem sérica da PCR e VHS. RESULTADOS: Após a comparação entre as variáveis testadas (deltaT, PCR e VHS), observou-se tanto para o teste de Pearson (avaliação paramétrica), quanto para o de Spearman (avaliação não-paramétrica) que não houve correlação estatística entre elas. A variação da temperatura cutânea segue um padrão diferente do observado tanto para a PCR quanto para a VHS, não existindo correlação entre as curvas. Foi estabelecida a curva padrão das três variáveis, verificando-se redução estatisticamente significativa nos valores da PCR e da VHS entre o pré e o pós-operatório. CONCLUSÃO: Não foi observada correlação entre a temperatura cutânea e os níveis de VHS e PCR em pacientes submetidos a ATJ primária, isenta de complicações.UNIFESPUFMG Faculdade de Medicina Departamento do Aparelho locomotorUFMG Serviço de Ortopedia do HCUNIFESPSciEL

    Femoral shaft fracture: reproducibility of AO-ASIF and Winquist classifications

    Get PDF
    OBJECTIVE: To evaluate inter-observer reproducibility of AO / ASIF and Winquist-Hansen classifications for shaft fractures of the femur in adults. METHODS: 50 anterior-posterior and profilelateral radiographs were randomly selected, of adult patients awith diaphyseal fracture of the femur. The radiographs were analyzed by 5 observers-a member of the Brazilian Society of Orthopedic Trauma, a radiologist and 3 residents. To assess the concordance between these classifications, we used the statistical index Kappa (K). RESULTS: In all analyses, we observed a statistically significant correlation coefficient between observers (p <0.05) and according to the criteria of Landis and Koch, they were ranked them as good (values of 0.61 to 0.80) or very good (values above 0.80). CONCLUSION: The AO rating and Winquist present a high rate of concordance between observers for shaft fractures of the femur in adults.OBJETIVO: Avaliar a reprodutibilidade interobservadores das classificações AO/ASIF e de Winquist para as fraturas diafisárias do fêmur no adulto. MÉTODOS: foram selecionadas aleatoriamente 50 radiografias de pacientes adultos portadores de fratura diafisária do fêmur nas incidências em antero-posterior e perfil. As radiografias foram analisadas por 5 observadores, sendo um membro da Sociedade Brasileira de Trauma Ortopédico, um radiologista, um residente do terceiro ano de Ortopedia e Traumatologia, um do segundo e um do primeiro. Para avaliar a concordância interobservadores destas classificações, foi utilizado o índice estatístico Kappa (K). RESULTADOS: Em todas as análises, observou-se um coeficiente de concordância entre observadores estatisticamente significativo (valor p < 0,05) e classificado como bom (valores de 0,61 a 0,80) ou muito bom (valores acima de 0,80), segundo os critérios de Landis e Koch. CONCLUSÃO: As classificações AO e Winquist apresentam alto índice de concordância interobservadores para as fraturas diafisárias do fêmur no adulto.Universidade Federal de Minas Gerais Hospitais Felício Rocho e da Baleia Departamento do Aparelho LocomotorUniversidade Federal de São Paulo (UNIFESP) Escola Paulista de MedicinaHospital Felício Rocho Serviço de Ortopedia e TraumatologiaUniversidade Federal de Minas Gerais Departamento do Aparelho LocomotorUNIFESP, EPMSciEL

    Relationship of the Pelvic-Trochanteric Index with greater trochanteric pain syndrome

    Get PDF
    OBJECTIVES: This study aimed to correlate a higher Pelvic-Trochanteric Index (PTI) with an increased varus of the femoral neck with greater trochanteric pain syndrome (GTPS). The secondary objective was to check whether the pelvic width changes with age. METHODS: A prospective study was conducted to compare female patients diagnosed with GTPS (case group) with asymptomatic female participants (control group) from March 2011 to June 2017. On an anteroposterior pelvic radiograph, lines were drawn by two radiologists, and the PTI (ratio of the distance between the greater trochanters and distance between the iliac crests) was defined and the femoral neck-shaft angle was measured. RESULTS: Data collected based on radiographs of 182 female patients (cases) and 150 female participants (controls) showed that the mean PTI was 1.09 (SD=0.01) in the case group and 1.07 (SD=0.01) in the control group (p&lt;0.05), regardless of age. The distance between iliac crests increased with age (p&lt;0.05) in symptomatic and asymptomatic individuals. It was also found that the mean femoral neck-shaft angle was 130.6° (SD=0.59) and progression of the varus angulation occurred with age in both groups, with a significance level of 5%. CONCLUSIONS: The PTI was higher in patients with GTPS. The femoral neck-shaft angle does not differ between individuals with and without GTPS; however, it does decrease with age. The pelvic width tends to increase with aging in symptomatic or asymptomatic individuals; therefore, the increase in the pelvic width and decrease in the femoral neck-shaft angle can be interpreted as normal in aging women, which could alter the biomechanics of the hips and pelvis

    Uso Terapêutico de Tecnologias Assistivas: direito das pessoas com deficiência e habilidade física e motora

    Get PDF
    Este curso integra um conjunto de quatro qualificações sobre o tema geral “uso terapêutico de tecnologias assistivas”, organizado com esta finalidade. Por meio deste módulo, o objetivo é promover a atualização sobre o uso terapêutico das tecnologias assistivas no âmbito da habilitação e da reabilitação das pessoas com deficiência, enfocando habilidade física e autonomia motora com utilização das órteses, próteses e meios auxiliares. Os temas abordados são: Contexto e pressupostos: pessoas com deficiências, direitos, políticas públicas e inclusão social; A atenção à saúde das pessoas com deficiência; Habilidade física e motora2015Ministério da Saúd

    TOURNIQUET VERSUS NO TOURNIQUET USE IN KNEE VIDEOARTHROSCOPY: A MULTICENTRIC, PROSPECTIVE, DOUBLE-BLIND, RANDOMIZED CLINICAL TRIAL

    Get PDF
    ABSTRACTTo evaluate whether, by using an arthropump (irrigation equipment with pressure sensor), pneumatic tourniquet use could interfere with the duration of surgery, recovery of movement and joint volume in patients who underwent knee videoarthroscopy for partial meniscectomy. Methods: 103 patients divided randomly into two groups regarding use or nonuse of a pneumatic tourniquet were evaluated in five different centers by seven different surgeons. The variables were evaluated during the surgery and seven days after the operation. Results: No statistically significant differences were found among any of the variables studied. Conclusion: There are no reasons that would either justify or discredit tourniquet use in this specific situation

    Reconstrução do ligamento cruzado anterior: impacto do desempenho muscular e funcional no retorno ao mesmo nível de atividade pré-lesão

    No full text
    INTRODUÇÃO: A reconstrução do LCA objetiva restabelecer a biomecânica e minimizar a instabilidade do joelho. OBJETIVO: comparar performance muscular, funcional e frouxidão ligamentar, entre voluntários que retornaram ao mesmo nível de atividade pré-lesão e aqueles que não retornaram, após a reconstrução ligamentar. MÉTODOS: 25 homens, operados pelo mesmo cirurgião, com o ligamento patelar, via artroscopia e mais de dois anos de pós-operatório. Utilizou-se a Cincinnati Knee Rating System para divisão em: grupo adaptado - 15 indivíduos - retornaram ao mesmo nível pré-lesão e grupo não adaptado - 10 indivíduos - não retornaram ao mesmo nível. Todos realizaram o hop test e a corrida em oito para avaliação do desempenho funcional. A performance muscular foi avaliada pelo dinamômetro isocinético (Biodex System 3 Pro®) e a frouxidão ligamentar determinada pelo artrômetro KT-1000 (Medmetric®). Utilizou-se o teste t independente e ANOVA para análise de associação. RESULTADOS: não houve diferença significativa entre os grupos em nenhuma das variáveis testadas e não houve diferença entre os membros - operado e não operado. CONCLUSÃO: O não retorno ao mesmo nível funcional pré-lesão não pode ser explicado pela frouxidão ligamentar residual ou pelas diferenças do desempenho muscular e funcional

    Tratamento cirúrgico da instabilidade fêmoro-patelar

    No full text
    OBJETIVO: Descrever os resultados funcionais do tratamento cirúrgico de pacientes portadores de instabilidade fêmoro-patelar submetidos a realinhamento do aparelho extensor. Métodos: Trata-se de estudo retrospectivo de 34 joelhos operados devido à instabilidade fêmoro-patelar no período de 1989 a 2004. Os pacientes foram avaliados no pós-operatório remoto, sendo aplicado questionário funcional. RESULTADOS: Em um seguimento médio de seis anos e cinco meses, o valor médio de pontuação foi de 82,94 pontos no grupo operado (p = 0,00037). Melhora do quadro de dor (97,05% de excelentes e bons resultados) e baixa taxa de recorrência dos episódios de luxação (5,88%) foram observadas no grupo, embora pontuações mais baixas tenham sido obtidas em atividades de maior demanda articular (agachamento, prática de corridas e execução de saltos). Nenhum dos pacientes avaliados desenvolveu artrose no tempo de seguimento. CONCLUSÃO: O procedimento de realinhamento articular descrito neste artigo mostrou-se eficaz no tratamento dos pacientes com instabilidade fêmoro-patelar recidivante

    SURGICAL TREATMENT OF PATELLOFEMORAL INSTABILITY

    Get PDF
    ABSTRACTObjective: To describe functional outcomes following surgical treatment of patients with patellofemoral instability submitted to patellar realignment. Methods: This was a retrospective study evaluating 34 operated knees for patellofemoral instability between 1989 and 2004. The patients were evaluated in the late postoperative period when a functional questionnaire was applied. Results: After a mean follow-up time of 6 years and 5 months, the mean score was 82.94 in the surgical group (p=0.00037). The results of this investigation showed pain relief in 97.05% and low rate of recurrent dislocation (5.88%), although lower scores were seen in intense articular activities (squatting, running and jumping). No patient developed osteoarthritis while being followed up. Conclusion: The procedure for joint described in this paper was shown to be effective for treating patients with recurrent patellofemoral instability

    Estudo comparativo funcional e radiográfico preliminar da artroplastia total do joelho com componente tibial metal-backed e all-polyethylene A functional and roentgenographic preliminary comparative study using metal-backed and all-polyethylene tibial components in total knee arthroplasty

    No full text
    OBJETIVO: Descrever e comparar clínica e radiograficamente pacientes submetidos a artroplastia total do joelho (ATJ) com implantes tibiais tipo all-polyethylene (ALP) e metal-backed (MTB). MÉTODOS: Pacientes submetidos a ATJ realizadas entre janeiro de 1998 e dezembro de 2004 foram agrupados de acordo com o tipo de implante recebido: all-polyethylene ou metal-backed. Sessenta pacientes compareceram para a avaliação, totalizando 82 joelhos operados. Destes, 22 pacientes haviam sido submetidos a ATJ apenas com ALP (12 unilaterais e 10 bilaterais), 33 pacientes apenas com MTB (26 unilaterais e sete bilaterais) e cinco pacientes foram submetidos a ATJ com ALP em um joelho e MTB em outro joelho, assim divididos: Grupo 1-37 joelhos com ALP e Grupo 2 - 45 joelhos com MTB. RESULTADOS: Não houve diferença na avaliação clínica e funcional entre os grupos. A média de radioluscência no fêmur foi de 0,838mm para os pacientes do grupo 1 e 0,356mm para os pacientes do grupo 2 (p = 0,049). Para a tíbia, na incidência AP, houve um valor médio de 2,703mm para o grupo 1 e de 0,733mm para o grupo 2 (p = 0,000). Na incidência em perfil, o valor médio de osteólise foi de 0,405mm para o grupo 1 e de 0,200mm para o grupo 2 (p = 0,074). CONCLUSÕES: Não houve diferença entre os grupos na avaliação clínica e funcional. Houve aumento da radioluscência nas artroplastias com ALP, tanto no fêmur na incidência em perfil quanto na tíbia na incidência em AP. Nível de evidência IV - Estudo tipo série de caso.<br>OBJECTIVE: To evaluate and clinically and roentgenographically compare two populations who had undergone total knee arthroplasty (TKA) with all-polyethylene (ALP) and metal-backed (MTB) tibial components. METHODS: Two groups of 40 patients underwent TKA between January 1988 and December 2004. Sixty patients showed up for evaluation, totaling 82 operated knees. From these, 22 patients had undergone TKA with only ALP (12 unilateral and 10 bilateral), 33 patients with only MTB (26 unilateral and 7 bilateral) and 5 patients had undergone both implants. The 82 operated knees were divided into two groups according to the type of tibial implant: Group 1 - 37 knees with ALP and Group 2 - 45 knees with MTB. RESULTS: There was no clinical or functional difference in outcome between the studied groups. The measurement of radioluscent line in the femoral component averaged 0.838 mm in Group 1 and 0.356 mm in Group 2 (p=0.049). For the tibial component, in the AP view radioluscent line measurement averaged 2.703 mm in Group 1 and 0.733 mm in Group 2 (p=0.000); and in the lateral view, the average values were 0.405 mm in Group 1 and 0.200 mm in Group 2 (p=0.074). CONCLUSIONS: There was no difference in the functional or clinical outcomes between the groups. However, radioluscent line was observed more frequently in the ALP arthroplasty group, in the lateral view in the femoral component as well as the AP view of the tibial component. Level of evidence IV - case series study
    corecore