98 research outputs found

    Deep Learning-based Polyp Detection in Wireless Capsule Endoscopy Images

    Get PDF
    Gastrointestinal (GI) system diseases have increased significantly, where colon and rectum cancer is considered the second cause of death in 2020. Wireless Capsule Endoscopy (WCE) is a revolutionary procedure for detecting Colorectal lesions. It was automatically used to detect the polyps, multiple SB lesions, bleeding, and Ulcer. The acquired video by the WCE can be processed using a Computer-Aided Diagnosis (CAD) system. However, such videos suffer several problems, including burling, high illumination. and distortion. These effects obligate the development of image processing techniques of high accuracy in detection using deep learning-based segmentation. In this paper, a transfer learning-based U-Net was proposed to transfer the knowledge between the medical images in the training phase and the subsequent segmentation using transfer learning to achieve better results and high accuracy results compared to other related studies. The improvement is done by using an algorism written in python code The results showed average segmentation accuracy of 98.67

    Modified Canny Detector-based Active Contour for Segmentation

    Get PDF
    In the present work, an integrated modified canny detector and an active contour were proposed for automated medical image segmentation. Since the traditional canny detector (TCD) detects only the edge’s pixels, which are insufficient for labelling the image, a shape feature was extracted to select the initial region of interest ‘IROI’ as an initial mask for the active contour without edge (ACWE), using a proposed modified canny detector (MCD). This procedure overcomes the drawback of the manual initialization of the mask location and shape in the traditional ACWE, which is sensitive to the shape of region of region of interest (ROI). The proposed method solves this problem by selecting the initial location and shape of the IROI using the MCD. Also, a post-processing stage was applied for more cleaning and smoothing the ROI. A practical computational time is achieved as the proposed system requires less than 5 minutes, which is significantly less than the required time using the traditional ACWE. The results proved the ability of the proposed method for medical image segmentation with average dice 87.54%

    Modified Canny Detector-based Active Contour for Segmentation

    Get PDF
    In the present work, an integrated modified canny detector and an active contour were proposed for automated medical image segmentation. Since the traditional canny detector (TCD) detects only the edge’s pixels, which are insufficient for labelling the image, a shape feature was extracted to select the initial region of interest ‘IROI’ as an initial mask for the active contour without edge (ACWE), using a proposed modified canny detector (MCD). This procedure overcomes the drawback of the manual initialization of the mask location and shape in the traditional ACWE, which is sensitive to the shape of region of region of interest (ROI). The proposed method solves this problem by selecting the initial location and shape of the IROI using the MCD. Also, a post-processing stage was applied for more cleaning and smoothing the ROI. A practical computational time is achieved as the proposed system requires less than 5 minutes, which is significantly less than the required time using the traditional ACWE. The results proved the ability of the proposed method for medical image segmentation with average dice 87.54%

    Optimized Adaptive Frangi-based Coronary Artery Segmentation using Genetic Algorithm

    Get PDF
    Diseases of coronary artery are deliberated as one of the most common heart diseases leading to death worldwide. For early detection of such disease, the X-ray angiography is a benchmark imaging modality for diagnosing such illness. The acquired X-ray angiography images usually suffer from low quality and the presence of noise. Therefore, for developing a computer-aided diagnosis (CAD) system, vessel enhancement and segmentation play significant role. In this paper, an optimized adapter filter based on Frangi filter was proposed for superior segmentation of the angiography images using genetic algorithm (GA). The original angiography image is initially preprocessed to enhance its contrast followed by generating the vesselness map using the proposed optimized Frangi filter. Then, a segmentation technique is applied to extract only the artery vessels, where the proposed system for extracting only the main vessel was evaluated. The experimental results on angiography images established the superiority of the vessel regions extraction showing 98.58% accuracy compared to the state-of-the-art

    DeepLab V3+ Based Semantic Segmentation of COVID -19 Lesions in Computed Tomography Images

    Get PDF
    Abstract- Coronavirus 2019 spreads rapidly worldwide causing a global epidemic. Early detection and diagnosis of COVID-19 is critical for treatment as it causes respiratory syndrome appears in the chest medical images, such as computed tomography (CT) images, and X-ray images. The CT images are more sensitive and have more details compared to the X-ray images. Thus, automated segmentation plays an imperative role in detecting, diagnosing, and determining the spreading of COVID-19. In this paper, the DeepLabV3+ combined with MobileNet-V2 model was implemented. To validate this combination, we conducted a comparative study between the DeepLabV3+ variants by its combination with MobileNet-V2 against DeepLabV3+ combined with different CNN, namely ResNet-18, and ResNet50. Also, a comparative study with the basic traditional U-Net and modified Alex for segmentation was carried out. The experimental results showed the superiority of the using DeepLabV3+ combined with MobileNet-V2 for COVID-19 segmentation by achieving 97.5% mean accuracy, 95.2% sensitivity, 99.7% specificity, 99.7% precision, 99.3 % weighted Jaccard coefficient, and 97.5% weighted dice coefficient

    Nonrigid Medical Image Registration using Adaptive Gradient Optimizer

    Get PDF
    Medical image registration has a significant role in several applications. It has sequential processes, including transformation, similarity metric calculation, diffusion regularization, and optimization of the transformation parameters (i.e., rotation, translation, and shear). The optimization process for determining the optimal set of the transformation vectors is considered the main stage affecting the performance of the registration process. Hence, medical image registration can be deliberated as an optimization problem for computing the geometric transformations to realize maximum similarity between the moving image and the fixed one. In this work, a mono-modal nonrigid image registration using B-spline is designed for the alignment of Computed Tomography (CT) images of thorax using Adaptive Gradient algorithm (AdaGrad) optimizer. In addition, a comparative study with other first order optimizers, such as Stochastic Gradient Descent (SGD), Adaptive Moment Estimation (Adam) algorithm (AdaMaX), AdamP, and RangerQH were conducted. Also, a comparison with the limited memory Broyden-Fletcher-Goldfarb-Shannon (LBFGS) as a second order optimizer was also carried out. The results showed the superiority of the AdaGrad optimizer by 56.99% and 48.37% improvement in the compared to the target registration error (TRE) compared to the SGD, and the LBFGS optimizer, respectively

    A novel optimized neutrosophic k-means using genetic algorithm for skin lesion detection in dermoscopy images

    Get PDF
    This paper implemented a new skin lesion detection method based on the genetic algorithm (GA) for optimizing the neutrosophic set (NS) operation to reduce the indeterminacy on the dermoscopy images. Then, k-means clustering is applied to segment the skin lesion regions
    • …