189 research outputs found

    Influence of sildenafil on blood oxygen saturation of the obstructed bladder

    Get PDF
    Background: Blood oxygen saturation (BOS) is decreased in a low-compliant, overactive obstructed bladder. The objective of this study is to determine the effect of Sildenafil (SC) on bladder function and BOS) in an in vivo animal model of bladder outlet obstruction. Methods. Thirty-two guinea pigs; sham operated (n = 8), sham operated + SC (n = 8), urethrally obstructed (n = 8) and urethrally obstructed + SC (n = 8) were studied during an 8 week period. BOS of the bladder wall was measured by differential path-length spectroscopy (DPS) before obstruction, at day 0, and at week 8. The bladder function was evaluated by urodynamic studies every week. Results: Before surgery and after sham operation all study parameters were comparable. After sham operation, bladder function and BOS did not change. In the obstructed group the urodynamic parameters were deteriorated and BOS was decreased. In the group obstruction + SC, bladder compliance remained normal and overactivity occurred only sporadic. BOS remained unchanged compared to the sham group and was significantly higher compared to the obstruction group. Conclusions: In an obstructed bladder the loss of bladder function is accompanied by a significant decrease in BOS. Treatment of obstructed bladders with SC yields a situation of high saturation, high bladder compliance and almost no overactivity. Maintaining the microcirculation of the bladder wall might result in better bladder performance without significant loss of bladder function. Measurement of BOS and interventions focussing on tissue microcirculation may have a place in the evaluation / treatment of various bladder dysfunctions

    Scattering phase Function Spectrum Makes Reflectance Spectrum Measured from Intralipid phantoms and Tissue Sensitive to the Device Detection Geometry

    Get PDF
    Reflectance spectra measured in Intralipid (IL) close to the source are sensitive to wavelength -dependent changes in reduced scattering coefficient (μs′)and scattering phase function (PF). Experiments and simulations were performed using device designs with either single or separate optical fibers for delivery and collection of light in varying concentrations of IL. Spectral reflectance is not consistentl y linear with varying IL concentration, with PF -dependent effects observed for single fiber devices with diameters smaller than ten transport lengths and for separate source- detector devices that collected light at less than half of a transport length from the source. Similar effects are thought to be seen in tissue, limiting the ability to quantitatively compare spectra from different devices without compensation

    Vibrational state distribution of 2-Na^+ ions created in ultracold collisions

    Get PDF
    The vibrational distribution P(v) of 2-Na^+ ions created in ultracold collisions in a magneto-optical trap has been deter- mined. Only two vibrational states with v = 2 and 3 are popu- lated and we find P(2)=0.29±0.02 and P(3)=0.71±0.02. The results provide conclusive evidence that the ionization mech- anism is photo-associative autoionization,and not photo- associative photoionization and will form a fundamental test for the theoretical description of the process

    Scattering phase function spectrum makes reflectance spectrum measured from Intralipid phantoms and tissue sensitive to the device detection geometry

    Get PDF
    Reflectance spectra measured in Intralipid (IL) close to the source are sensitive to wavelength-dependent changes in reduced scattering coefficient (μ′s) and scattering phase function (PF). Experiments and simulations were performed using device designs with either single or separate optical fibers for delivery and collection of light in varying concentrations of IL. Spectral reflectance is not consistently linear with varying IL concentration, with PF-dependent effects observed for single fiber devices with diameters smaller than ten transport lengths and for separate source-detector devices that collected light at less than half of a transport length from the source. Similar effects are thought to be seen in tissue, limiting the ability to quantitatively compare spectra from different devices without compensation

    Extraction of Intrinsic Fluorescence from Single Fiber Fluorescence Measurements on a Turbid Medium: Experimental Validation

    Get PDF
    Abstract The detailed mechanisms associated with the influence of scattering and absorption properties on the fluorescence intensity sampled by a single optical fiber have recently been elucidated based on Monte Carlo simulated data. Here we develop an experimental single fiber fluorescence (SFF) spectroscopy setup and validate the Monte Carlo data and semi-empirical model equation that describes the SFF signal as a function of scattering. We present a calibration procedure that corrects the SFF signal for all system-related, wavelength dependent transmission efficiencies to yield an absolute value of intrinsic fluorescence. The validity of the Monte Carlo data and semi-empirical model is demonstrated using a set of fluorescent phantoms with varying concentrations of Intralipid to vary the scattering properties, yielding a wide range of reduced scattering coefficients (μ′s = 0–7 mm −1). We also introduce a small modification to the model to account for the case of μ′s = 0 mm −1 and show its relation to the experimental, simulated and theoretically calculated value of SFF intensity in the absence of scattering. Finally, we show that our method is also accurate in the presence of absorbers by performing measurements on phantoms containing red blood cells and correcting for their absorption properties

    Optical Detection of Preneoplastic Lesions of the Central Airways

    Get PDF
    Current routine diagnosis of premalignant lesions of the central airways is hampered due to a limited sensitivity (white light bronchoscopy) and resolution (computer tomography (CT), positron emission tomography (PET)) of currently used techniques. To improve the detection of these subtle mucosal abnormalities, novel optical imaging bronchoscopic techniques have been developed over the past decade. In this review we highlight the technological developments in the field of endoscopic imaging, and describe their advantages and disadvantages in clinical use

    In vivo quantification of photosensitizer fluorescence in the skin-fold observation chamber using dual-wavelength excitation and NIR imaging

    Get PDF
    A major challenge in biomedical optics is the accurate quantification of in vivo fluorescence images. Fluorescence imaging is often used to determine the pharmacokinetics of photosensitizers used for photodynamic therapy. Often, however, this type of imaging does not take into account differences in and changes to tissue volume and optical properties of the tissue under interrogation. To address this problem, a ratiometric quantification method was developed and applied to monitor photosensitizer meso-tetra (hydroxyphenyl) chlorin (mTHPC) pharmacokinetics in the rat skin-fold observation chamber. The method employs a combination of dual-wavelength excitation and dualwavelength detection. Excitation and detection wavelengths were selected in the NIR region. One excitation wavelength was chosen to be at the Q band of mTHPC, whereas the second excitation wavelength was close to its absorption minimum. Two fluorescence emission bands were used; one at the secondary fluorescence maximum of mTHPC centered on 720 nm, and one in a region of tissue autofluorescence. The first excitation wavelength was used to excite the mTHPC and autofluorescence and the second to excite only autofluorescence, so that this could be subtracted. Subsequently, the autofluorescence-corrected mTHPC image was divided by the autofluorescence signal to correct for variations in tissue optical properties. This correction algorithm in principle results in a linear relation between the corrected fluorescence and photosensitizer concentration. The limitations of the presented method and comparison with previously published and validated techniques are discussed

    Optical detection of field cancerization in the buccal mucosa of patients with esophageal cancer

    Get PDF
    Introduction: Esophageal cancer is an increasingly common type of neoplasm with a very poor prognosis. This prognosis could improve with more early tumor detection. We have previously shown that we can use an optical spectroscopy to detect field cancerization in the buccal mucosa of patients with laryngeal cancer. The aim of this prospective study was to investigate whether we could detect field cancerization of buccal mucosa of patients with esophageal squamous cell carcinoma (ESCC) and esophageal adenocarcinoma (EAC). Methods: Optical measurements were performed in vivo using a novel optical technique: multidiameter single-fiber reflectance (MDSFR) spectroscopy. MDSFR spectra were acquired by a handheld probe incorporating three fiber diameters. Multiple absorption and scattering parameters that are related to the physiological and ultrastructural properties of the buccal mucosa were derived from these spectra. A linear discriminant analysis of the parameters was performed to create a combined biomarker σ to discriminate oncologic from non-oncologic patients. Results: Twelve ESCC, 12 EAC, and 24 control patients were included in the study. The median value of our biomarker σ was significantly higher in patients with ESCC (2.07 [1.93-2.10]) than control patients (1.86 [1.73-1.95], p = 0.022). After cross-validation σ was able to identify ESCC patients with a sensitivity of 66.7% and a specificity of 70.8%. There were no significant differences between the EAC group and the control group. Conclusion: Field cancerization in the buccal mucosa can be detected using optical spectroscopy in ESCC patients. This may be the first step towards non-invasive ESCC cancer screening

    The future of medical diagnostics: Review paper

    Get PDF
    While histopathology of excised tissue remains the gold standard for diagnosis, several new, non-invasive diagnostic techniques are being developed. They rely on physical and biochemical changes that precede and mirror malignant change within tissue. The basic principle involves simple optical techniques of tissue interrogation. Their accuracy, expressed as sensitivity and specificity, are reported in a number of studies suggests that they have a potential for cost effective, real-time, in situ diagnosis. We review the Third Scientific Meeting of the Head and Neck Optical Diagnostics Society held in Congress Innsbruck, Innsbruck, Austria on the 11th May 2011. For the first time the HNODS Annual Scientific Meeting was held in association with the International Photodynamic Association (IPA) and the European Platform for Photodynamic Medicine (EPPM). The aim was to enhance the interdisciplinary aspects of optical diagnostics and other photodynamic applications. The meeting included 2 sections: oral communication sessions running in parallel to the IPA programme and poster presentation sessions combined with the IPA and EPPM posters sessions. © 2011 Jerjes et al; licensee BioMed Central Ltd
    corecore