33 research outputs found

    Evaluation of phosphatidylserine-dependent antiprothrombin antibody testing for the diagnosis of antiphospholipid syndrome: results of an international multicentre study.

    Get PDF
    OBJECTIVE: A task force of scientists at the International Congress on Antiphospholipid Antibodies recognized that phosphatidylserine-dependent antiprothrombin antibodies (aPS/PT) might contribute to a better identification of antiphospholipid syndrome (APS). Accordingly, initial and replication retrospective, cross-sectional multicentre studies were conducted to ascertain the value of aPS/PT for APS diagnosis. METHODS: In the initial study (eight centres, seven countries), clinical/laboratory data were retrospectively collected. Serum/plasma samples were tested for IgG aPS/PT at Inova Diagnostics (Inova) using two ELISA kits. A replication study (five centres, five countries) was carried out afterwards. RESULTS: In the initial study (n = 247), a moderate agreement between the IgG aPS/PT Inova and MBL ELISA kits was observed (k = 0.598). IgG aPS/PT were more prevalent in APS patients (51%) than in those without (9%), OR 10.8, 95% CI (4.0-29.3), p < 0.0001. Sensitivity, specificity, positive (LR+) and negative (LR-) likelihood ratio of IgG aPS/PT for APS diagnosis were 51%, 91%, 5.9 and 0.5, respectively. In the replication study (n = 214), a moderate/substantial agreement between the IgG aPS/PT results obtained with both ELISA kits was observed (k = 0.630). IgG aPS/PT were more prevalent in APS patients (47%) than in those without (12%), OR 6.4, 95% CI (2.6-16), p < 0.0001. Sensitivity, specificity, LR + and LR- for APS diagnosis were 47%, 88%, 3.9 and 0.6, respectively. CONCLUSIONS: IgG aPS/PT detection is an easily performed laboratory parameter that might contribute to a better and more complete identification of patients with APS.info:eu-repo/semantics/publishedVersio

    DEVELOPMENT OF FUEL CHARACTERIZATION TOOL BASED ON LIBRARY INTERPOLATION

    Get PDF
    The feasibility of using Origen+ARP code for depletion and decay calculations for Krško NPP was tested by performing depletion and decay calculations using interpolated libraries and comparing the results to the ones calculated from non-interpolated libraries in order to evaluated the number of libraries needed in order to interpolate fuel properties with sufficient precision for any realistic burnup scenario. For Krško NPP fuel, using three interpolation libraries with different decay heat parameters was enough to bring the approximation error bellow 0:5 % when comparing fuel decay heat through the decay interval

    DEVELOPMENT OF FUEL CHARACTERIZATION TOOL BASED ON LIBRARY INTERPOLATION

    No full text
    The feasibility of using Origen+ARP code for depletion and decay calculations for Krško NPP was tested by performing depletion and decay calculations using interpolated libraries and comparing the results to the ones calculated from non-interpolated libraries in order to evaluated the number of libraries needed in order to interpolate fuel properties with sufficient precision for any realistic burnup scenario. For Krško NPP fuel, using three interpolation libraries with different decay heat parameters was enough to bring the approximation error bellow 0:5 % when comparing fuel decay heat through the decay interval

    Gamma-heating and gamma flux measurements in the JSI TRIGA reactor, results and prospects

    Get PDF
    The neutron field of various irradiation positions of the TRIGA Mark II reactor of the Jožef Stefan Institute has been thoroughly characterized by neutron activation dosimetry and miniature fission chambers techniques. In order to have a fully validated calculation scheme to analyze and plan experiments, the gamma field also has to be experimentally validated. The 10-year long collaboration between CEA and JSI is a perfect framework to carry out such a study, and measurements of the gamma field started in late 2016. Several measurement techniques were investigated in in-core and ex-core positions. On-line measurements were carried out using miniature ionization chambers manufactured by the CEA and PTW Farmer ionization chambers. Positional dependence was studied, showing a decrease in the delayed gamma contribution to the total gamma flux with increasing distance from the reactor core center. To characterize the gamma dose in the core, as well as in the periphery, thermo- and optically stimulated luminescent detectors were tested. These detectors are commonly used at CEA to measure the gamma dose in a given material in order to study the nuclear heating in various core elements (control rod, baffle, structural material). Different filters were used in order to assess an integrated dose ranging from a few Gy up to several kGy. The feasibility of such measurements demonstrates the complementarity between measurements with dosimetry and ionization chambers from low to very high gamma-dose environment, such as in material testing reactors

    Gamma-heating and gamma flux measurements in the JSI TRIGA reactor, results and prospects

    No full text
    International audienceThe neutron field of various irradiation positions of the TRIGA Mark II reactor of the Jožef Stefan Institute has been thoroughly characterized by neutron activation dosimetry and miniature fission chambers techniques. In order to have a fully validated calculation scheme to analyze and plan experiments, the gamma field also has to be experimentally validated. The 10-year long collaboration between CEA and JSI is a perfect framework to carry out such a study, and measurements of the gamma field started in late 2016. Several measurement techniques were investigated in in-core and ex-core positions. On-line measurements were carried out using miniature ionization chambers manufactured by the CEA and PTW Farmer ionization chambers. Positional dependence was studied, showing a decrease in the delayed gamma contribution to the total gamma flux with increasing distance from the reactor core center. To characterize the gamma dose in the core, as well as in the periphery, thermo-and optically stimulated luminescent detectors were tested. These detectors are commonly used at CEA to measure the gamma dose in a given material in order to study the nuclear heating in various core elements (control rod, baffle, structural material). Different filters were used in order to assess an integrated dose ranging from a few Gy up to several kGy. The feasibility of such measurements demonstrates the complementarity between measurements with dosimetry and ionization chambers from low to very high gamma-dose environment, such as in material testing reactors

    Epitaxial growth of Al9Ir2 intermetallic compound on Al(100): Mechanism and interface structure

    No full text
    International audienceThe adsorption of Ir adatoms on Al(100) has been investigated under various exposures and temperature conditions. The experimental and theoretical results reveal a diffusion of Ir adatoms within the Al(100) surface selvedge already at 300 K. Above 593 K, two domains of a (√ 5× √ 5)R26.6 • phase are identified by low energy electron diffraction (LEED) and scanning tunneling microscopy measurements. This phase corresponds to the initial growth of an Al 9 Ir 2 compound at the Al(100) surface. The Al 9 Ir 2 intermetallic domains are terminated by bulklike pure Al layers. The structural stability of Al 9 Ir 2 (001) grown on Al(100) has been analyzed by density functional theory based calculations. Dynamical LEED analysis is consistent with an Ir adsorption leading to the growth of an Al 9 Ir 2 intermetallic compound. We propose that the epitaxial relationship Al 9 Ir 2 (001)Al(100) and Al 9 Ir 2 [100]Al[031]/[013] originates from a matching of Al atomic arrangements present both on Al(100) and on pure Al(001) layers present in the Al 9 Ir 2 compound. Finally, the interface between Al 9 Ir 2 precipitates and the Al matrix has been characterized by transmission electron microscopy measurements. The cross-sectional observations are consistent with the formation of Al 9 Ir 2 (001) compounds. These measurements indicate an important Ir diffusion within Al(100) near the surface region. The coherent interface between Al 9 Ir 2 and the Al matrix is sharp
    corecore