79 research outputs found

    Characterization of Susceptibility Artifacts in MR-thermometry PRFS-based during Laser Interstitial Thermal Therapy

    Get PDF
    Magnetic Resonance Thermometry (MRT) is demonstrating huge abilities to guide laser interstitial thermal therapy (LITT) in several organs, such as the brain. Among the methods to perform MRT, Proton Resonance Frequency (PRF) shift holds significant benefits, like tissue independence. Despite its potential, PRF shift-based MRT holds significant challenges affecting the accuracy of reconstructed temperature maps. In particular, susceptibility artifacts due to gas-bubble formation are an important source of error in temperature maps in MRT-guided LITT. This work presents the characterization of the susceptibility artifacts in MRT-guided LITT and the measurement of its size. LITT was performed in gelatin-based phantoms, at 5 W, 2 W, 1 W, and 0.5 W under MRI guidance with a 1.5 T clinical MRI scanner. Temperature images were obtained with a 3D EPI (Echo planar imaging) prototype sequence. Areas of temperature errors were defined as zones of negative temperature variation <-2 degrees C. Moreover, we have analyzed the artifact shape in sagittal, axial and coronal planes. The analysis demonstrates a double-lobe shape for the susceptibility artifact mainly distributed in the sagittal plane. Also, the higher laser power caused a bigger artifact area. Temperature errors of similar to 80 degrees C proved the necessity to avoid susceptibility artifact generation during MRT-guided LITT. The analysis of the influence of the laser power on the artifact has suggested that using low laser power (0.5 W) helps avoid this measurement error

    Influence of portal vein occlusion on portal flow and liver elasticity in an animal model

    Get PDF
    Hepatic fibrosis causes an increase in liver stiffness, a parameter measured by elastography and widely used as a diagnosis method. The concomitant presence of portal vein thrombosis (PVT) implies a change in hepatic portal inflow that could also affect liver elasticity. The main objective of this study is to determine the extent to which the presence of portal occlusion can affect the mechanical properties of the liver and potentially lead to misdiagnosis of fibrosis and hepatic cirrhosis by elastography. Portal vein occlusion was generated by insertion and inflation of a balloon catheter in the portal vein of four swines. The portal flow parameters peak flow (PF) and peak velocity magnitude (PVM) and liver mechanical properties (shear modulus) were then investigated using 4D-flow MRI and MR elastography, respectively, for progressive obstructions of the portal vein. Experimental results indicate that the reduction of the intrahepatic venous blood flow (PF/PVM decreases of 29.3%/8.5%, 51.0%/32.3% and 83.3%/53.6%, respectively) measured with 50%, 80% and 100% obstruction of the portal vein section results in a decrease of liver stiffness by 0.8%±0.1%0.8\%\pm0.1\%, 7.7%±0.4%7.7\%\pm0.4\% and 12.3%±0.9%12.3\%\pm0.9\%, respectively. While this vascular mechanism does not have sufficient influence on the elasticity of the liver to modify the diagnosis of severe fibrosis or cirrhosis (F4 METAVIR grade), it may be sufficient to attenuate the increase in stiffness due to moderate fibrosis (F2-F3 METAVIR grades) and consequently lead to false-negative diagnoses with elastography in the presence of PVT

    Characterization of susceptibility artifacts in magnetic resonance thermometry images during laser interstitial thermal therapy: dimension analysis and temperature error estimation

    Get PDF
    Objective: Laser interstitial thermal therapy (LITT) is a minimally invasive procedure used to treat a lesion through light irradiation and consequent temperature increase. Magnetic Resonance Thermometry Imaging (MRTI) provides a multidimensional measurement of the temperature inside the target thus enabling accurate monitoring of the zone of damage during the procedure. In proton resonance frequency shift-based thermometry, artifacts in the images may strongly interfere with the estimated temperature maps. In our work, after noticing the formation of the dipolar-behavior artifact linkable to magnetic susceptibility changes during in vivo LITT, an investigation of susceptibility artifacts in tissue-mimicking phantoms was implemented. Approach: The artifact was characterized: (i) by measuring the area and total volume of error regions and their evolution during the treatment; and (ii) by comparison with temperature reference provided by three temperature sensing needles. Lastly, a strategy to avoid artifacts formation was devised by using the temperature-sensing needles to implement a temperature-controlled LITT. Main results: The artifact appearance was associated with gas bubble formation and with unwanted treatment effects producing magnetic susceptibility changes when 2 W laser power was set. The analysis of the artifact's dimension demonstrated that in the sagittal plane the dipolar-shape artifact may consistently spread following the temperature trend until reaching a volume 8 times bigger than the ablated one. Also, the artifact shape is quite symmetric with respect to the laser tip. An absolute temperature error showing a negative Gaussian profile in the area of susceptibility artifact with values up to 64.4 °C was estimated. Conversely, a maximum error of 2.8 °C is measured in the area not-affected by artifacts and far from the applicator tip. Finally, by regulating laser power, susceptibility artifacts formation was avoided, and appreciable thermal damage was induced. Significance: Such findings may help in improving the MRTI-based guidance of thermal therapies

    Alzheimer's Disease-Associated Cerebrospinal Fluid (CSF) Biomarkers do not Correlate with CSF Volumes or CSF Production Rate

    Get PDF
    BACKGROUND: Neuropathologically, Alzheimer’s disease (AD) is characterized by accumulation of a 42 amino acid peptide called amyloid-β (Aβ42) in extracellular senile plaques together with intraneuronal inclusions of hyperphosphorylated tau protein in neurofibrillary tangles and neuronal degeneration. These changes are reflected in the cerebrospinal fluid (CSF), the volumes and production rates of which vary considerably between individuals, by reduced concentration of Aβ42, increased concentration of phosphorylated tau (P-tau) protein, and increased concentration of total tau (T-tau) protein, respectively. OBJECTIVE: To examine the outstanding question if CSF concentrations of AD associated biomarkers are influenced by variations in CSF volumes, CSF production rate, and intracranial pressure in healthy individuals. Methods: CSF concentrations of Aβ42, P-tau, and T-tau, as well as a number of other AD-related CSF biomarkers were analyzed together with intracranial subarachnoid, ventricular, and spinal CSF volumes, as assessed by magnetic resonance imaging volumetric measurements, and CSF production rate in 19 cognitively normal healthy subjects (mean age 70.6, SD 3.6 years). RESULTS: Negative correlations were seen between the concentrations of three CSF biomarkers (albumin ratio, Aβ38, and Aβ40), and ventricular CSF volume, but apart from this finding, no significant correlations were observed. CONCLUSION: These results speak against inter-individual variations in CSF volume and production rate as important confounds in the AD biomarker research field

    Analysis of cavitation artifacts in Magnetic Resonance Imaging Thermometry during laser ablation monitoring

    Get PDF
    : Magnetic Resonance Thermometry Imaging (MRTI) holds great potential in laser ablation (LA) monitoring. It provides the real-time multidimensional visualization of the treatment effect inside the body, thus enabling accurate intraoperative prediction of the thermal damage induced. Despite its great potential., thermal maps obtained with MRTI may be affected by numerous artifacts. Among the sources of error producing artifacts in the images., the cavitation phenomena which could occur in the tissue during LA induces dipole-structured artifacts. In this work., an analysis of the cavitation artifacts occurring during LA in a gelatin phantom in terms of symmetry in space and symmetry of temperature values was performed. Results of 2 Wand 4 W laser power were compared finding higher symmetry for the 2 W case in terms of both dimensions of artifact-lobes and difference in temperature values extracted in specular pixels in the image. This preliminary investigation of artifact features may provide a step forward in the identification of the best strategy to correct and avoid artifact occurrence during thermal therapy monitoring. Clinical Relevance- This work presents an analysis of cavitation artifacts in MRTI from LA which must be corrected to avoid error in the prediction of thermal damage during LA monitoring

    Magnetic Resonance Elastography and Portal Hypertension: Influence of the Portal Venous Flow on the Liver Stiffness

    Get PDF
    International audienceThe invasive measurement of the hepatic venous pressure gradient is still considered as the reference method to assess the severity of portal hypertension. Even though previous studies have shown that the liver stiffness measured by elastography could predict portal hypertension in patients with chronic liver disease, the mechanisms behind remain today poorly understood. The main reason is that the liver stiffness is not specific to portal hypertension and is also influenced by concomitant pathologies, such as cirrhosis. Portal hypertension is also source of a vascular incidence, with a substantial diversion of portal venous blood to the systemic circulation, bypassing the liver. This study focuses on this vascular effect of portal hypertension. We propose to generate and control the portal venous flow (to isolate the modifications in the portal venous flow as single effect of portal hypertension) in an anesthetized pig and then to quantify its implications on liver stiffness by an original combination of MRE and 4D-Flow Magnetic Resonance Imaging (MRI). A catheter balloon is progressively inflated in the portal vein and the peak flow, peak velocity magnitude and liver stiffness are quantified in a 1.5T MRI scanner (AREA, Siemens Healthcare, Erlangen, Germany). A strong correlation is observed between the portal peak velocity magnitude, the portal peak flow or the liver stiffness and the portal vein intraluminal obstruction. Moreover, the comparison of mechanical and flow parameters highlights a correlation with the possibility of identifying linear relationships. These results give preliminary indications about how liver stiffness can be affected by portal venous flow and, by extension, by hypertension

    Post-Acquisition Processing Confounds in Brain Volumetric Quantification of White Matter Hyperintensities

    Get PDF
    BACKGROUND: Disparate research sites using identical or near-identical magnetic resonance imaging (MRI) acquisition techniques often produce results that demonstrate significant variability regarding volumetric quantification of white matter hyperintensities (WMH) in the aging population. The sources of such variability have not previously been fully explored. NEW METHOD: 3D FLAIR sequences from a group of randomly selected aged subjects were analyzed to identify sources-of-variability in post-acquisition processing that can be problematic when comparing WMH volumetric data across disparate sites. The methods developed focused on standardizing post-acquisition protocol processing methods to develop a protocol with less than 0.5% inter-rater variance. RESULTS: A series of experiments using standard MRI acquisition sequences explored post-acquisition sources-of-variability in the quantification of WMH volumetric data. Sources-of-variability included: the choice of image center, software suite and version, thresholding selection, and manual editing procedures (when used). Controlling for the identified sources-of-variability led to a protocol with less than 0.5% variability between independent raters in post-acquisition WMH volumetric quantification. COMPARISON WITH EXISTING METHOD(S): Post-acquisition processing techniques can introduce an average variance approaching 15% in WMH volume quantification despite identical scan acquisitions. Understanding and controlling for such sources-of-variability can reduce post-acquisition quantitative image processing variance to less than 0.5%. DISCUSSION: Considerations of potential sources-of-variability in MRI volume quantification techniques and reduction in such variability is imperative to allow for reliable cross-site and cross-study comparisons
    corecore