79 research outputs found

    Detecting volcanic sulfur dioxide plumes in the Northern Hemisphere using the Brewer spectrophotometer, other networks, and satellite observations

    Get PDF
    This paper demonstrates that SO 2 columnar amounts have significantly increased following the five largest volcanic eruptions of the past decade in the Northern Hemisphere. A strong positive signal was detected by all the existing networks either ground based (Brewer, EARLINET, AirBase) or from satellites (OMI, GOME-2). The study particularly examines the adequacy of the existing Brewer network to detect SO 2 plumes of volcanic origin in comparison to other networks and satellite platforms. The comparison with OMI and 45 GOME-2 SO 2 space-borne retrievals shows statistically significant agreement between the Brewer network data and the collocated satellite overpasses. It is shown that the Brewer instrument is capable of detecting significant columnar SO 2 increases following large volcanic eruptions, when SO 2 levels rise well above the instrumental noise of daily observations, estimated to be of the order of 2 DU. A model exercise from the MACC project shows that the large increases of SO 2 over Europe following the Bárðarbunga eruption in Iceland were not caused by local sources or ship emissions but are clearly linked to the eruption. We propose that by combining Brewer data with that from other networks and satellites, a useful tool aided by trajectory analyses and modeling could be created which can be used to forecast high SO 2 values both at ground level and in air flight corridors following future eruptions

    Reduction of blood culture contamination rate by an educational intervention

    Get PDF
    Background: Although mechanical dyssynchrony parameters derived by speckle tracking echocardiography (STE) may predict response to cardiac resynchronization therapy (CRT), comparability of parameters derived with different STE vendors is unknown. Methods: In the MARC study, echocardiographic images of heart failure patients obtained before CRT implantation were prospectively analysed with vendor specific STE software (GE EchoPac and Philips QLAB) and vendor-independent software (TomTec 2DCPA). Response was defined as change in left ventricular (LV) end-systolic volume between examination before and six-months after CRT implantation. Basic longitudinal strain and mechanical dyssynchrony parameters (septal to lateral wall delay (SL-delay), septal systolic rebound stretch (SRSsept), and systolic stretch index (SSI)) were obtained from either separate septal and lateral walls, or total LV apical four chamber. Septal strain patterns were categorized in three types. The coefficient of variation and intra-class correlation coefficient (ICC) were analysed. Dyssynchrony parameters were associated with CRT response using univariate regression analysis and C-statistics. Results: Two-hundred eleven patients were analysed. GE-cohort (n = 123): age 68 years (interquartile range (IQR): 61-73), 67% male, QRS-duration 177ms (IQR: 160-192), LV ejection fraction: 26 +/- 7%. Philips-cohort (n = 88): age 67 years (IQR: 59-74), 60% male, QRS-duration: 179 ms (IQR: 166-193), LV ejection fraction: 27 +/- 8. LV derived peak strain was comparable in the GE-(GE: -7.3 +/- 3.1%, TomTec: -6.4 +/- 2.8%, ICC: 0.723) and Philips-cohort (Philips: -7.7 +/- 2.7%, TomTec: -7.7 +/- 3.3%, ICC: 0.749). SL-delay showed low ICC values (GE vs. TomTec: 0.078 and Philips vs. TomTec: 0.025). ICC's of SRSsept and SSI were higher but only weak (GE vs. TomTec: SRSsept: 0.470, SSI: 0.467) (Philips vs. QLAB: SRSsept: 0.419, SSI: 0.421). Comparability of septal strain patterns was low (Cohen's kappa, GE vs. TomTec: 0.221 and Philips vs. TomTec: 0.279). Septal strain patterns, SRSsept and SSI were associated with changes in LV end-systolic volume for all vendors. SRSsept and SSI had relative varying C-statistic values (range: 0.530-0.705) and different cut-off values between vendors. Conclusions: Although global longitudinal strain analysis showed fair comparability, assessment of dyssynchrony parameters was vendor specific and not applicable outside the context of the implemented platform. While the standardization taskforce took an important step for global peak strain, further standardization of STE is still warranted

    Multi-Sensor Reanalysis (MSR) of total ozone, version 2

    No full text
    The ozone multi-sensor reanalysis (MSR) is a multi-decadal ozone column data record constructed using all available ozone column satellite data sets, surface Brewer and Dobson observations and a data assimilation technique with detailed error modelling. The result is a high-resolution time series of 6-hourly global ozone column fields and forecast error fields that may be used for ozone trend analyses as well as detailed case studies

    TEMIS UV index and UV dose MSR-2 data products, version 2

    No full text
    The TEMIS UV index and UV dose data are computed from the assimilated global ozone field at local solar noon, i.e. at the moment the Sun is highest in the sky, which in case of the UV dose is combined with the daily variation of the position of the Sun above the horizon

    TEMIS UV index and UV dose operational data products, version 2

    No full text
    The TEMIS UV index and UV dose data are computed from the assimilated global ozone field at local solar noon, i.e. at the moment the Sun is highest in the sky, which in case of the UV dose is combined with the daily variation of the position of the Sun above the horizon

    Ozone profiles in the high-latitude stratosphere and lower mesosphere measured by the Improved Limb Atmospheric Spectrometer (ILAS)-II: Comparison with other satellite sensors and ozonesondes

    Get PDF
    A solar occultation sensor, the Improved Limb Atmospheric Spectrometer (ILAS)-II, measured 5890 vertical profiles of ozone concentrations in the stratosphere and lower mesosphere and of other species from January to October 2003. The measurement latitude coverage was 54–71°N and 64–88°S, which is similar to the coverage of ILAS (November 1996 to June 1997). One purpose of the ILAS-II measurements was to continue such high-latitude measurements of ozone and its related chemical species in order to help accurately determine their trends. The present paper assesses the quality of ozone data in the version 1.4 retrieval algorithm, through comparisons with results obtained from comprehensive ozonesonde measurements and four satellite-borne solar occultation sensors. In the Northern Hemisphere (NH), the ILAS-II ozone data agree with the other data within ±10% (in terms of the absolute difference divided by its mean value) at altitudes between 11 and 40 km, with the median coincident ILAS-II profiles being systematically up to 10% higher below 20 km and up to 10% lower between 21 and 40 km after screening possible suspicious retrievals. Above 41 km, the negative bias between the NH ILAS-II ozone data and the other data increases with increasing altitude and reaches 30% at 61–65 km. In the Southern Hemisphere, the ILAS-II ozone data agree with the other data within ±10% in the altitude range of 11–60 km, with the median coincident profiles being on average up to 10% higher below 20 km and up to 10% lower above 20 km. Considering the accuracy of the other data used for this comparative study, the version 1.4 ozone data are suitably used for quantitative analyses in the high-latitude stratosphere in both the Northern and Southern Hemisphere and in the lower mesosphere in the Southern Hemisphere

    Снижение потерь при электродуговой сварке

    No full text
    BACKGROUND: The aims of this study were to determine the optimal tracer kinetic model for [(11)C]-meta-hydroxyephedrine ([(11)C]HED) and to evaluate the performance of several simplified methods. METHODS: Thirty patients underwent dynamic 60-min [(11)C]HED scans with online arterial blood sampling. Single-tissue and both reversible and irreversible two-tissue models were fitted to the data using the metabolite-corrected arterial input function. For each model, reliable fits were defined as those yielding outcome parameters with a coefficient of variation (CoV) <25%. The optimal model was determined using Akaike and Schwarz criteria and the F-test, together with the number of reliable fits. Simulations were performed to study accuracy and precision of each model. Finally, quantitative results obtained using a population-averaged metabolite correction were evaluated, and simplified retention index (RI) and standardized uptake value (SUV) results were compared with quantitative volume of distribution (V T) data. RESULTS: The reversible two-tissue model was preferred in 75.8% of all segments, based on the Akaike information criterion. However, V T derived using the single-tissue model correlated highly with that of the two-tissue model (r (2) = 0.94, intraclass correlation coefficient (ICC) = 0.96) and showed higher precision (CoV of 24.6% and 89.2% for single- and two-tissue models, respectively, at 20% noise). In addition, the single-tissue model yielded reliable fits in 94.6% of all segments as compared with 77.1% for the reversible two-tissue model. A population-averaged metabolite correction could not be used in approximately 20% of the patients because of large biases in V T. RI and SUV can provide misleading results because of non-linear relationships with V T. CONCLUSIONS: Although the reversible two-tissue model provided the best fits, the single-tissue model was more robust and results obtained were similar. Therefore, the single-tissue model was preferred. RI showed a non-linear correlation with V T, and therefore, care has to be taken when using RI as a quantitative measure
    corecore