3,106 research outputs found
Chiral metamaterials with negative refractive index based on four "U" split ring resonators
A uniaxial chiral metamaterial is constructed by double-layered four "U"
split ring resonators mutually twisted by 90 degrees. It shows a giant optical
activity and circular dichroism. The retrieval results reveal that a negative
refractive index is realized for circularly polarized waves due to the large
chirality. The experimental results are in good agreement with the numerical
results.Comment: 4 pages, 4 figures, Published as cover on AP
A panel analysis of UK industrial company failure
We examine the failure determinants for large quoted UK industrials using a panel data set
comprising 539 firms observed over the period 1988-93. The empirical design employs data
from company accounts and is based on Chamberlain’s conditional binomial logit model,
which allows for unobservable, firm-specific, time-invariant factors associated with failure
risk. We find a noticeable degree of heterogeneity across the sample companies. Our panel
results show that, after controlling for unobservables, lower liquidity measured by the quick
assets ratio, slower turnover proxied by the ratio of debtors turnover, and profitability were
linked to the higher risk of insolvency in the analysis period. The findings appear to support
the proposition that the current cash-flow considerations, rather than the future prospects of
the firm, determined company failures over the 1990s recession
First measurement of production in pp collisions at = 7 TeV
The production of the charm-strange baryon is measured for
the first time at the LHC via its semileptonic decay into e
in pp collisions at TeV with the ALICE detector. The transverse
momentum () differential cross section multiplied by the branching
ratio is presented in the interval 1 8 GeV/ at
mid-rapidity, 0.5. The transverse momentum dependence of the
baryon production relative to the D meson production is
compared to predictions of event generators with various tunes of the
hadronisation mechanism, which are found to underestimate the measured
cross-section ratio.Comment: 22 pages, 6 captioned figures, 1 table, authors from page 17,
published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/412
Measurement of an excess in the yield of J/ at very low in Pb-Pb collisions at = 2.76 TeV
We report on the first measurement of an excess in the yield of J/ at
very low transverse momentum ( GeV/) in peripheral hadronic
Pb-Pb collisions at = 2.76 TeV, performed by ALICE at the
CERN LHC. Remarkably, the measured nuclear modification factor of J/ in
the rapidity range reaches about 7 (2) in the range 0-0.3
GeV/ in the 70-90% (50-70%) centrality class. The J/ production cross
section associated with the observed excess is obtained under the hypothesis
that coherent photoproduction of J/ is the underlying physics mechanism.
If confirmed, the observation of J/ coherent photoproduction in Pb-Pb
collisions at impact parameters smaller than twice the nuclear radius opens new
theoretical and experimental challenges and opportunities. In particular,
coherent photoproduction accompanying hadronic collisions may provide insight
into the dynamics of photoproduction and nuclear reactions, as well as become a
novel probe of the Quark-Gluon Plasma.Comment: 18 pages, 3 captioned figures, 1 table, authors from page 13,
published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/191
Constraining the magnitude of the Chiral Magnetic Effect with Event Shape Engineering in Pb-Pb collisions at = 2.76$ TeV
In ultrarelativistic heavy-ion collisions, the event-by-event variation of
the elliptic flow reflects fluctuations in the shape of the initial state
of the system. This allows to select events with the same centrality but
different initial geometry. This selection technique, Event Shape Engineering,
has been used in the analysis of charge-dependent two- and three-particle
correlations in Pb-Pb collisions at TeV. The
two-particle correlator ,
calculated for different combinations of charges and , is
almost independent of (for a given centrality), while the three-particle
correlator
scales almost linearly both with the event and charged-particle
pseudorapidity density. The charge dependence of the three-particle correlator
is often interpreted as evidence for the Chiral Magnetic Effect (CME), a parity
violating effect of the strong interaction. However, its measured dependence on
points to a large non-CME contribution to the correlator. Comparing the
results with Monte Carlo calculations including a magnetic field due to the
spectators, the upper limit of the CME signal contribution to the
three-particle correlator in the 10-50% centrality interval is found to be
26-33% at 95% confidence level.Comment: 20 pages, 6 captioned figures, 1 tables, authors from page 15,
published version, figures at
http://aliceinfo.cern.ch/ArtSubmission/node/382
Energy dependence of exclusive photoproduction off protons in ultra-peripheral p-Pb collisions at = 5.02 TeV
The ALICE Collaboration has measured the energy dependence of exclusive
photoproduction of vector mesons off proton targets in
ultra-peripheral p-Pb collisions at a centre-of-mass energy per nucleon pair
TeV. The ee and decay channels
are used to measure the cross section as a function of the rapidity of the
in the range , corresponding to an energy in the
p centre-of-mass in the interval GeV.
The measurements, which are consistent with a power law dependence of the
exclusive photoproduction cross section, are compared to previous
results from HERA and the LHC and to several theoretical models. They are found
to be compatible with previous measurements.Comment: 25 pages, 3 captioned figures, 3 tables, authors from page 19,
published version, figures at http://alice-publications.web.cern.ch/node/455
Measurement of the production of charm jets tagged with D mesons in pp collisions at = 7 TeV
The production of charm jets in proton-proton collisions at a center-of-mass
energy of TeV was measured with the ALICE detector at the CERN
Large Hadron Collider. The measurement is based on a data sample corresponding
to a total integrated luminosity of , collected using a
minimum-bias trigger. Charm jets are identified by the presence of a D
meson among their constituents. The D mesons are reconstructed from their
hadronic decay DK. The D-meson tagged jets are
reconstructed using tracks of charged particles (track-based jets) with the
anti- algorithm in the jet transverse momentum range
and pseudorapidity
. The fraction of charged jets containing a D-meson
increases with from to . The distribution of D-meson tagged jets as a
function of the jet momentum fraction carried by the D meson in the
direction of the jet axis () is reported for two ranges
of jet transverse momenta, and
in the intervals
and , respectively. The
data are compared with results from Monte Carlo event generators (PYTHIA 6,
PYTHIA 8 and Herwig 7) and with a Next-to-Leading-Order perturbative Quantum
Chromodynamics calculation, obtained with the POWHEG method and interfaced with
PYTHIA 6 for the generation of the parton shower, fragmentation, hadronisation
and underlying event.Comment: 29 pages, 8 captioned figures, 3 tables, authors from page 24,
published version, figures at http://alice-publications.web.cern.ch/node/525
A new Low Gain Avalanche Diode concept: the double-LGAD
This paper describes the new concept of the double-LGAD. The goal is to
increase the charge at the input of the electronics, keeping a time resolution
equal or better than a standard (single) LGAD; this has been realized by adding
the charges of two coupled LGADs while still using a single front-end
electronics. The study here reported has been done starting from single LGAD
with a thickness of 25 \textmu{m}, 35 \textmu{m} and 50 \textmu{m}.Comment: arXiv admin note: text overlap with arXiv:2208.0571
Performance evaluation of parallel manipulators for milling application
This paper focuses on the performance evaluation of the parallel manipulators
for milling of composite materials. For this application the most significant
performance measurements, which denote the ability of the manipulator for the
machining are defined. In this case, optimal synthesis task is solved as a
multicriterion optimization problem with respect to the geometric, kinematic,
kinetostatic, elastostostatic, dynamic properties. It is shown that stiffness
is an important performance factor. Previous models operate with links
approximation and calculate stiffness matrix in the neighborhood of initial
point. This is a reason why a new way for stiffness matrix calculation is
proposed. This method is illustrated in a concrete industrial problem
[89Zr]Oxinate4 for long-term in vivo cell tracking by positron emission tomography
Purpose 111In (typically as [111In]oxinate3) is a gold standard
radiolabel for cell tracking in humans by scintigraphy. A long
half-life positron-emitting radiolabel to serve the same purpose
using positron emission tomography (PET) has long
been sought. We aimed to develop an 89Zr PET tracer for cell
labelling and compare it with [111In]oxinate3 single photon
emission computed tomography (SPECT).
Methods [89Zr]Oxinate4 was synthesised and its uptake and
efflux were measured in vitro in three cell lines and in human
leukocytes. The in vivo biodistribution of eGFP-5T33 murine
myeloma cells labelled using [89Zr]oxinate4 or [111In]oxinate3
was monitored for up to 14 days. 89Zr retention by living
radiolabelled eGFP-positive cells in vivo was monitored by
FACS sorting of liver, spleen and bone marrow cells followed
by gamma counting.
Results Zr labelling was effective in all cell types with yields
comparable with 111In labelling. Retention of 89Zr in cells
in vitro after 24 h was significantly better (range 71 to
>90 %) than 111In (43–52 %). eGFP-5T33 cells in vivo
showed the same early biodistribution whether labelled with
111In or 89Zr (initial pulmonary accumulation followed by
migration to liver, spleen and bone marrow), but later translocation
of radioactivity to kidneys was much greater for 111In.
In liver, spleen and bone marrow at least 92 % of 89Zr
remained associated with eGFP-positive cells after 7 days
in vivo.
Conclusion [89Zr]Oxinate4 offers a potential solution to the
emerging need for a long half-life PET tracer for cell tracking
in vivo and deserves further evaluation of its effects on survival
and behaviour of different cell types
- …