This paper describes the new concept of the double-LGAD. The goal is to
increase the charge at the input of the electronics, keeping a time resolution
equal or better than a standard (single) LGAD; this has been realized by adding
the charges of two coupled LGADs while still using a single front-end
electronics. The study here reported has been done starting from single LGAD
with a thickness of 25 \textmu{m}, 35 \textmu{m} and 50 \textmu{m}.Comment: arXiv admin note: text overlap with arXiv:2208.0571