2,422 research outputs found

    Fires enhance flammability in Ulex parviflorus

    Get PDF
    6 páginas, 2 figuras, 2 tablas.This work was financed by the VIRRA project (CGL2009-12048 ⁄ BOS) from the Spanish Government. G.A.A. is supported by a Juan de la Cierva scholarship (JDC 2009-5067; Spanish Government) and B.M. by an FCT grant (SFRH ⁄BD⁄ 41343 ⁄ 2007; Portuguese Government). CIDE is supported by the Spanish National Research Council (CSIC), Generalitat Valenciana and the University of Valencia. We thank R. Bossi (CEAM, GRACCIE project, CONSOLIDERINGENIO 2010), E. Beltran, S. Paula, J. Chofre and O. González-Pelayo for their collaboration in the field and laboratory work, M. C. Castellanos for comments on an early version of the manuscript, and Fundación Caja Castellón-Bancaja for permission to work in Barranc dels Horts (Ares del Maestrat).Peer reviewe

    Large Horizontal Near-field Scanner based on a Non-tethered Unmanned Aerial Vehicle

    Get PDF
    A horizontal planar scanner with an approximate size of 40 m x 40 m has been implemented using the Unmanned Aerial Vehicle (UAV) technology. The UAV is not wired to the ground to maintain the flexibility and short setup time of a non-tethered flight. In this configuration, the UAV-mounted continuous-wave source is not phase-locked to the on-the-ground receiver. A dual-polarized reference antenna placed on the ground is hence used to retrieve the relevant phase information. The presented approach has been applied on the Pre - Aperture Array Verification System (Pre -AAVS1) of the Square Kilometre Array, which is a digital beamformed array with 16 active elements. An inverse source technique has been applied on measured Near-Field (NF) data acquired on two different sets of points (one for each electric field component) from all the receiver channels. In this way, Embedded Element Patterns (EEPs), array calibration coefficients and pattern have been determined from NF data only. The achieved results have been validated using a complementary set of Far-Field (FF) measurements and simulations

    Determining the Quantum Expectation Value by Measuring a Single Photon

    Get PDF
    Quantum mechanics, one of the keystones of modern physics, exhibits several peculiar properties, differentiating it from classical mechanics. One of the most intriguing is that variables might not have definite values. A complete quantum description provides only probabilities for obtaining various eigenvalues of a quantum variable. These and corresponding probabilities specify the expectation value of a physical observable, which is known to be a statistical property of an ensemble of quantum systems. In contrast to this paradigm, we demonstrate a unique method allowing to measure the expectation value of a physical variable on a single particle, namely, the polarisation of a single protected photon. This is the first realisation of quantum protective measurements.Comment: Nature Physics, in press (this version corresponds to the one initially submitted to Nature Physics

    Real-time evaluation of longitudinal peak systolic strain (speckle tracking measurement) in left and right ventricles of athletes

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Strain, and particularly Longitudinal Peak Systolic Strain (LPSS), plays a role in investigating the segmental and overall contractility of the heart which is a particularly interesting feature in athletes in whom regular training determines several morphological and functional modifications in both the ventricles, that normally work at different loads. Speckle tracking techniques assess the LPSS of LV and RV from B-mode imaging in real time, with uniform accuracy in all segments, and can verify the possible dissimilar segmental contributions of the two chambers to overall myocardial contraction. The aim of the study is to quantify the LPSS in real time in both the ventricles in order to estimate any possible different deformation properties in them during a systolic period.</p> <p>Methods</p> <p>32 subjects (20 athletes and 18 controls) were submitted to a standard echocardiographic examination at rest and after a Hand Grip (HG) stress. From a four-chamber-view image, the LPSS parameter was measured with Speckle Tracking analysis in the basal and medium-apical segments of the two ventricles, at rest and after HG.</p> <p>Results</p> <p>In both athletes and controls, LPSS values were significantly higher in the RV of athletes (RV LPSS <sup>medium-apical </sup>-23.87 ± 4.94; <sup>basalfreewall </sup>-25.04 ± 4.12 at rest) and controls (RV LPSS<sup>medium-apical </sup>-25.21 ± 4.97; <sup>basalfreewall </sup>-28.69 ± 4.62 at rest) than in the LV of both (athletes LV LPSS <sup>medium-apical </sup>-18.14 ± 4.16; <sup>basallateralwall </sup>-16.05 ± 12.32; controls <sup>medium-apical </sup>-18.81 ± 2.64; <sup>basallateralwall </sup>-19.74 ± 3.84) With the HG test a significant enhancement of the LPSS(with P < .05) in the medium-apical segments of LV and RV was evident, but only in athletes; there was no modification of the standard echo-parameters in either group.</p> <p>Conclusion</p> <p>ST analysis is an easy method for investigating the contractility of the RV through deformation parameters, showing greater involvement of the RV than LV at rest. In athletes only, after isometric stress the two ventricles show particular myocardial deformation properties of the regions around the apex where the curvature of the wall is more marked. The clinical application of this new approach in athletes and normal subjects requires further investigation.</p

    A Journey from Thermally Tunable Synthesis to Spectroscopy of Phenylmethanimine in Gas Phase and Solution

    Get PDF
    Phenylmethanimine is an aromatic imine with a twofold relevance in chemistry: organic synthesis and astrochemistry. To tackle both aspects, a multidisciplinary strategy has been exploited and a new, easily accessible synthetic approach to generate stable imine-intermediates in the gas phase and in solution has been introduced. The combination of this formation pathway, based on the thermal decomposition of hydrobenzamide, with a state-of-the-art computational characterization of phenylmethanimine laid the foundation for its first laboratory observation by means of rotational electric resonance spectroscopy. Both E and Z isomers have been accurately characterized, thus providing a reliable basis to guide future astronomical observations. A further characterization has been carried out by nuclear magnetic resonance spectroscopy, showing the feasibility of this synthetic approach in solution. The temperature dependence as well as possible mechanisms of the thermolysis process have been examined. © 2020 The Authors. Published by Wiley-VCH Gmb

    High-density hyaluronic acid for the treatment of HIV-related facial lipoatrophy

    Get PDF
    Facial lipoatrophy is a stigmatizing hallmark of HIV. The injection of facial fillers has an essential role in the treatment of this condition. The objective of our study was to verify the safety and efficacy of a new formulation of high-density hyaluronic acid for the injectable treatment of HIV-related facial lipoatrophy.We treated with high-density hyaluronic acid injections HIV patients affected by moderate to severe facial lipoatrophy and evaluated them at last follow-up, at a minimum of 36 weeks. Physician-related outcomes included pre-and post-treatment ultrasound measurement of the soft-tissue thickness of the cheeks and qualitative assessment of aesthetic results by means of the Global Aesthetic Improvement Scale using pre- and post-treatment photos of the patients. Patient satisfaction outcomes were evaluated with the VAS-face scale and Freiburg test.Fifty-four patients were studied. The median number of treatment sessions was 3 and the median length of treatment was 5.5 months. The thickness of the soft tissues of the cheek increased significantly from 9.45 to 13.12 mm (p&lt;0.0001). On the basis of the Global Aesthetic Improvement Scale, 87.5% of the patients were judged as "much improved" or "improved." Patient satisfaction at 1 year from the end of treatment was proven (VAS-face: 77.9; Freiburg questionnaire: 93.6% of patients were satisfied or very satisfied). Complications were limited to mild redness and swelling in the early postoperative period.Long-term improvement of facial contour and excellent patient satisfaction, in the absence of severe side effects, were obtained by the injection of high-density hyaluronic acid (STYLAGE\uae XL) in HIV patients with facial lipoatrophy

    Tissue Doppler Imaging can be useful to distinguish pathological from physiological left ventricular hypertrophy: a study in master athletes and mild hypertensive subjects

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Transthoracic echocardiography left ventricular wall thickness is often increased in master athletes and it results by intense physical training. Left Ventricular Hypertrophy can also be due to a constant pressure overload. Conventional Pulsed Wave (PW) Doppler analysis of diastolic function sometimes fails to distinguish physiological from pathological LVH.</p> <p>The aim of this study is to evaluate the role of Pulsed Wave Tissue Doppler Imaging in differentiating pathological from physiological LVH in the middle-aged population.</p> <p>Methods</p> <p>we selected a group of 80 master athletes, a group of 80 sedentary subjects with essential hypertension and an apparent normal diastolic function at standard PW Doppler analysis. The two groups were comparable for increased left ventricular wall thickness and mass index (134.4 ± 19.7 vs 134.5 ± 22.1 gr/m2; p > .05). Diastolic function indexes using the PW technique were in the normal range for both.</p> <p>Results</p> <p>Pulsed Wave TDI study of diastolic function immediately distinguished the two groups. While in master athletes the diastolic TDI-derived parameters remained within normal range (E' 9.4 ± 3.1 cm/sec; E/E' 7.8 ± 2.1), in the hypertensive group these parameters were found to be constantly altered, with mean values and variation ranges always outside normal validated limits (E' 7.2 ± 2.4 cm/sec; E/E' 10.6 ± 3.2), and with E' and E/E' statistically different in the two groups (p < .001).</p> <p>Conclusion</p> <p>Our study showed that the TDI technique can be an easy and validated method to assess diastolic function in differentiating normal from pseudonormal diastolic patterns and it can distinguish physiological from pathological LVH emphasizing the eligibility certification required by legal medical legislation as in Italy.</p

    Measurement of the cosmic ray spectrum above 4×10184{\times}10^{18} eV using inclined events detected with the Pierre Auger Observatory

    Full text link
    A measurement of the cosmic-ray spectrum for energies exceeding 4×10184{\times}10^{18} eV is presented, which is based on the analysis of showers with zenith angles greater than 60∘60^{\circ} detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above 5.3×10185.3{\times}10^{18} eV, the "ankle", the flux can be described by a power law E−γE^{-\gamma} with index Îł=2.70±0.02 (stat)±0.1 (sys)\gamma=2.70 \pm 0.02 \,\text{(stat)} \pm 0.1\,\text{(sys)} followed by a smooth suppression region. For the energy (EsE_\text{s}) at which the spectral flux has fallen to one-half of its extrapolated value in the absence of suppression, we find Es=(5.12±0.25 (stat)−1.2+1.0 (sys))×1019E_\text{s}=(5.12\pm0.25\,\text{(stat)}^{+1.0}_{-1.2}\,\text{(sys)}){\times}10^{19} eV.Comment: Replaced with published version. Added journal reference and DO
    • 

    corecore