605 research outputs found
Dynamic heterodyne near field scattering
The technique heterodyne near field scattering (HNFS), originally developed for low-angle static light scattering, has also been implemented for carrying out dynamic light scattering. While the classical dynamic light scattering method measures the intensity-intensity correlation function, dynamic HNFS gives directly the field-field correlation function, without any assumption on the statistical properties of the sample, as the ones required by the Siegert relation. The technique has been tested with calibrated Brownian particles and its performances compared to those of the classical dynamic light scattering method.The technique heterodyne near field scattering (HNFS), originally developed for low-angle static light scattering, has also been implemented for carrying out dynamic light scattering. While the classical dynamic light scattering method measures the intensity-intensity correlation function, dynamic HNFS gives directly the field-field correlation function, without any assumption on the statistical properties of the sample, as the ones required by the Siegert relation. The technique has been tested with calibrated Brownian particles and its performances compared to those of the classical dynamic light scattering method. \ua9 2008 American Institute of Physics
Heterodyne speckle velocimetryof Poiseuille flow
We review the technique named heterodyne speckle velocimetry and present two applications for
testing the method with a fluid moving under the conditions of Poiseuille flow. The fluid was seeded
with small tracking particles diameter 300 nm and fluxed between the two parallel planes of a cell
with constant or variable cross section. In the first case the velocity distribution was constant along
the direction parallel to the planes and was in excellent agreement with the expected Poiseuille
profile along the orthogonal direction. In the second case, where velocity gradients were present also
along the planes, the technique was able to reconstruct both the orthogonal Poiseuille profile and the
in-plane two dimensional mapping of the velocity vectors, with the possibility of measuring the fluid
flux within an accuracy of 1%
Comparison of dogs treated for primary immune-mediated hemolytic anemia in Tuscany, Italy and Texas, USA
This retrospective study compared clinical characteristics between dogs treated for IMHA by veterinary teaching hospitals in Tuscany, Italy and Texas, USA between 2010 and 2018
Factors influencing the first thousand days of life
The first 1,000 days is a vulnerable phase in which parents, institutions and health professionals should create early interventions for the proper development and promotion of good health
Probing Transverse Coherence with the Heterodyne Speckle Approach: Overview and Perspectives☆
Abstract The properties of spatial coherence of radiation emitted by relativistic electrons is far from being trivial. Assessing the coherence of high-brilliance X-ray sources (3rd generation synchrotrons or free electron lasers) is of crucial importance for machine diagnostics, as well as in planning experiments exploiting coherent techniques. The Heterodyne Speckles method, firstly described by Alaimo et al. (2009), is a valuable alternative to standard methods (e.g. Young's interferometer) which 1) provides a direct measure of transverse coherence without any a-priori assumption, 2) provides a full 2D map of coherence, 3) is capable of one shot, time-resolved measures, 4) is scalable over a wide range of wavelengths. It relies upon the statistical analysis of radiation scattered by spherical particles randomly distributed and suspended in a fluid. Here we give an overview of this method, from the theoretical framework to the operating conditions to be adopted in order to obtain coherence measurements in several conditions
DEGGs: an R package with shiny app for the identification of differentially expressed gene-gene interactions in high-throughput sequencing data
Feed particle size evaluation: conventional approach versus digital holography based image analysis
The aim of this study was to evaluate the application of image analysis approach based on digital holography in defining particle size in comparison with the sieve shaker method (sieving method) as reference method. For this purpose ground corn meal was analyzed by a sieve shaker Retsch VS 1000 and by image analysis approach based on digital holography. Particle size from digital holography were compared with results obtained by screen (sieving) analysis for each of size classes by a cumulative distribution plot. Comparison between particle size values obtained by sieving method and image analysis indicated that values were comparable in term of particle size information, introducing a potential application for digital holography and image analysis in feed industry
Network analysis of synovial RNA sequencing identifies gene-gene interactions predictive of response in rheumatoid arthritis
Abstract Background To determine whether gene-gene interaction network analysis of RNA sequencing (RNA-Seq) of synovial biopsies in early rheumatoid arthritis (RA) can inform our understanding of RA pathogenesis and yield improved treatment response prediction models. Methods We utilized four well curated pathway repositories obtaining 10,537 experimentally evaluated gene-gene interactions. We extracted specific gene-gene interaction networks in synovial RNA-Seq to characterize histologically defined pathotypes in early RA and leverage these synovial specific gene-gene networks to predict response to methotrexate-based disease-modifying anti-rheumatic drug (DMARD) therapy in the Pathobiology of Early Arthritis Cohort (PEAC). Differential interactions identified within each network were statistically evaluated through robust linear regression models. Ability to predict response to DMARD treatment was evaluated by receiver operating characteristic (ROC) curve analysis. Results Analysis comparing different histological pathotypes showed a coherent molecular signature matching the histological changes and highlighting novel pathotype-specific gene interactions and mechanisms. Analysis of responders vs non-responders revealed higher expression of apoptosis regulating gene-gene interactions in patients with good response to conventional synthetic DMARD. Detailed analysis of interactions between pairs of network-linked genes identified the SOCS2/STAT2 ratio as predictive of treatment success, improving ROC area under curve (AUC) from 0.62 to 0.78. We identified a key role for angiogenesis, observing significant statistical interactions between NOS3 (eNOS) and both CAMK1 and eNOS activator AKT3 when comparing responders and non-responders. The ratio of CAMKD2/NOS3 enhanced a prediction model of response improving ROC AUC from 0.63 to 0.73. Conclusions We demonstrate a novel, powerful method which harnesses gene interaction networks for leveraging biologically relevant gene-gene interactions leading to improved models for predicting treatment response
Screening and Management of Coronary Artery Disease in Kidney Transplant Candidates
Cardiovascular disease (CVD) is a major cause of morbidity and mortality in patients with chronic kidney disease (CKD), especially in end-stage renal disease (ESRD) patients and during the first year after transplantation. For these reasons, and due to the shortage of organs available for transplant, it is of utmost importance to identify patients with a good life expectancy after transplant and minimize the transplant peri-operative risk. Various conditions, such as severe pulmonary diseases, recent myocardial infarction or stroke, and severe aorto-iliac atherosclerosis, need to be ruled out before adding a patient to the transplant waiting list. The effectiveness of systematic coronary artery disease (CAD) treatment before kidney transplant is still debated, and there is no universal screening protocol, not to mention that a nontailored screening could lead to unnecessary invasive procedures and delay or exclude some patients from transplantation. Despite the different clinical guidelines on CAD screening in kidney transplant candidates that exist, up to today, there is no worldwide universal protocol. This review summarizes the key points of cardiovascular risk assessment in renal transplant candidates and faces the role of noninvasive cardiovascular imaging tools and the impact of coronary revascularization versus best medical therapy before kidney transplant on a patient’s cardiovascular outcome
- …