3,035 research outputs found

    Axion search with a quantum-limited ferromagnetic haloscope

    Full text link
    A ferromagnetic axion haloscope searches for Dark Matter in the form of axions by exploiting their interaction with electronic spins. It is composed of an axion-to-electromagnetic field transducer coupled to a sensitive rf detector. The former is a photon-magnon hybrid system, and the latter is based on a quantum-limited Josephson parametric amplifier. The hybrid system consists of ten 2.1 mm diameter YIG spheres coupled to a single microwave cavity mode by means of a static magnetic field. Our setup is the most sensitive rf spin-magnetometer ever realized. The minimum detectable field is 5.5×10−19 5.5\times10^{-19}\,T with 9 h integration time, corresponding to a limit on the axion-electron coupling constant gaee≤1.7×10−11g_{aee}\le1.7\times10^{-11} at 95% CL. The scientific run of our haloscope resulted in the best limit on DM-axions to electron coupling constant in a frequency span of about 120 MHz, corresponding to the axion mass range 42.442.4-43.1 μ43.1\,\mueV. This is also the first apparatus to perform an axion mass scanning by changing the static magnetic field.Comment: 4 pages, 4 figure

    Clinical associations of serum antiendothelial cell antibodies in patients with sudden sensorineural hearing loss

    Get PDF
    Objectives/Hypothesis: The role of antiendothelial cell antibodies in systemic vasculitis has been reported. The. aim of the study was to define the clinical associations of serum antiendothelial cell antibodies in patients with sudden sensorineural hearing loss. Study Design: A prospective study in patients with sudden sensorineural hearing loss. Methods: Serum samples were taken from 59 consecutive patients with sudden sensorineural hearing loss at time of presentation and from 28 normal control subjects. Indirect immunofluorescence assay was used to detect antiendothelial cell antibodies. Results: The prevalence of antiendothelial cell antibody detection was 54% (32 of 59 patients), with a statistically significant difference between patients and control subjects (P = .0064). Antiendothelial cell antibody positivity was significantly associated with absent recovery of hearing loss (P = .0020). Conclusions: The cytotoxicity to endothelial cells of the inner ear by antiendothelial cell antibody-positive sera might play a role in causing the stria vascularis damage in immune-mediated sudden sensorineural deafness. The appearance of antiendothelial cell antibody is related to the poor outcome of hearing loss, and its detection could be helpful in the selection of particular patients with sensorineural hearing loss for specific immunosuppressive treatments

    Intelligent agents & interoperable simulation for strategic decision making on multicoalition joint operations

    Get PDF
    This paper proposes an innovative interoperable federation developed for addressing strategic decision making on multi-coalition operations. The proposed architecture integrates several different simulators in HLA and is open to be operated in different modes from stand alone basic installation to fully integrated with entity based simulations. The simulator uses Intelligent Agents, to reproduce human behavior and human factors, as well as discrete event simulation paradigm into virtual and constructive environments. The paper describes the models as well as the approach to address this problem; some experimental results related a realistic scenario are proposed as well as the different a solutions adopted to support Commander engagement in using this kind of simulation

    The use of high aspect ratio photoresist (SU-8) for super-hydrophobic pattern prototyping

    Get PDF
    In this work we present a reliable technique for the production of large areas of high aspect-ratio patterns and describe their use as model super-hydrophobic systems. The high thickness and straight sidewalls possible with SU-8 were used to generate dense patterns of small pillars. These photoresist patterns could be used directly, without the need for micromoulding. A method is given allowing resist thickness to be varied over a wide range and a bottom antireflective layer was used to simplify patterning on reflective substrates. This patterning technique allows rapid testing of wetting theories, as pattern size and depth can be varied simply and samples can be produced in sufficient numbers for laboratory use. We show how the static contact angle of water varies with pattern height for one sample-pattern and how static and dynamic contact angles vary with dimension using high aspect-ratio patterns

    First-principles prediction of structure, energetics, formation enthalpy, elastic constants, polarization, and piezoelectric constants of AlN, GaN, and InN: comparison of local and gradient-corrected density-functional theory

    Get PDF
    A number of diverse bulk properties of the zincblende and wurtzite III-V nitrides AlN, GaN, and InN, are predicted from first principles within density functional theory using the plane-wave ultrasoft pseudopotential method, within both the LDA (local density) and GGA (generalized gradient) approximations to the exchange-correlation functional. Besides structure and cohesion, we study formation enthalpies (a key ingredient in predicting defect solubilities and surface stability), spontaneous polarizations and piezoelectric constants (central parameters for nanostructure modeling), and elastic constants. Our study bears out the relative merits of the two density functional approaches in describing diverse properties of the III-V nitrides (and of the parent species N2_2, Al, Ga, and In), and leads us to conclude that the GGA approximation, associated with high-accuracy techniques such as multiprojector ultrasoft pseudopotentials or modern all-electron methods, is to be preferred in the study of III-V nitrides.Comment: RevTeX 6 pages, 12 tables, 0 figure

    Clemastine/tamoxifen hybrids as easily accessible antileishmanial drug leads

    Get PDF
    A library of hybrid molecules is developed based on the common chemical features shared by clemastine and tamoxifen both of which are well known for their antileishmanial activities. In the initial screening against Leishmania major and L. amazonensis promastigotes, as well as cytotoxicity assays using HepG2 cells, several hybrids showed submicromolar activity against the parasite and no toxicity against human cells. The compounds with an EC50 10 were further characterized against intracellular amastigotes as well as promastigotes of species that cause both visceral and cutaneous leishmaniasis, such as L. infantum and L. braziliensis, respectively. These sequential screenings revealed the high pan-activity of this class of molecules against these species, with several compounds displaying an EC50 ≤ 2 μM against both promastigotes and intracellular amastigotes. Two of them were identified as the potential templates for lead optimization of this series having shown the highest activities against all species in both stages of parasite. The present findings can serve as a good starting point in the search for novel antileishmanial compounds that are easy to access and highly active

    Validation of numerical approaches for electromagnetic characterization of magnetic resonance radiofrequency coils

    Get PDF
    Numerical methods based on solutions of Maxwell's equations are usually adopted for the electromagnetic characterization of Magnetic Resonance (MR) Radiofrequency (RF) coils. In this context, many different numerical methods can be employed, including time domain methods, e.g., the Finite-Difference Time-Domain (FDTD), and frequency domain methods, e.g., the Finite Element Methods (FEM) and the Method of Moments (MoM). We provide a quantitative comparison of performances and a detailed evaluation of advantages and limitations of the aforementioned methods in the context of RF coil design for MR applications. Specifically, we analyzed three RF coils which are representative of current geometries for clinical applications: a 1.5 T proton surface coil; a 7T dual tuned surface coil; a 7T proton volume coil. The numerical simulation results have been compared with measurements, with excellent agreement in almost every case. However, the three methods differ in terms of required computing resources (memory and simulation time) as well as their ability to handle a realistic phantom model. For this reason, this work could provide "a guide to select the most suitable method for each specific research and clinical applications at low and high field"
    • …
    corecore