40 research outputs found

    Human-activity-centered measurement system:challenges from laboratory to the real environment in assistive gait wearable robotics

    Get PDF
    Assistive gait wearable robots (AGWR) have shown a great advancement in developing intelligent devices to assist human in their activities of daily living (ADLs). The rapid technological advancement in sensory technology, actuators, materials and computational intelligence has sped up this development process towards more practical and smart AGWR. However, most assistive gait wearable robots are still confined to be controlled, assessed indoor and within laboratory environments, limiting any potential to provide a real assistance and rehabilitation required to humans in the real environments. The gait assessment parameters play an important role not only in evaluating the patient progress and assistive device performance but also in controlling smart self-adaptable AGWR in real-time. The self-adaptable wearable robots must interactively conform to the changing environments and between users to provide optimal functionality and comfort. This paper discusses the performance parameters, such as comfortability, safety, adaptability, and energy consumption, which are required for the development of an intelligent AGWR for outdoor environments. The challenges to measuring the parameters using current systems for data collection and analysis using vision capture and wearable sensors are presented and discussed

    Estimation of Actuation System Parameters for Prosthetic Ankle

    Get PDF
    The loss in mobility following amputation results in a degradation of the quality of life of the amputees as it affects many aspects of their personal and professional lives. Lower limb prostheses are used to replace the lost limbs and assist amputees in restoring their missing mobility functions. Despite the current technological advances in prosthetics, amputees still suffer from gait asymmetry and high metabolic energy costs. The gait asymmetry pattern and high metabolic energy costs occur due to: the inability to deliver the required level of assistance/power at the right time and the inertia and mass distribution asymmetry between the intact and the prosthetic leg

    Real-time gait event detection using a miniature gyroscope to improve rehabilitation for artificial lower limb users

    Get PDF
    This paper presents a simple heuristic rule based on real-time gait event detection algorithm for transfemoral amputees based on gyroscope signal and validate with footswitches for ramp activities with different inclinatio

    A Wearable Skin Stretch Haptic Feedback Device: Towards Improving Balance Control in Lower Limb Amputees

    Get PDF
    Haptic feedback to lower limb amputees is essential to maximize the functionality of a prosthetic device by providing information to the user about the interaction with the environment and the position of the prostheses in space. Severed sensory pathway and the absence of connection between the prosthesis and the Central Nervous System (CNS) after lower limb amputation reduces balance control, increases visual dependency and increases risk of falls among amputees. This work describes the design of a wearable haptic feedback device for lower limb amputees using lateral skin-stretch modality intended to serve as a feedback cue during ambulation. A feedback scheme was proposed based on gait event detection for possible real-time postural adjustment. Preliminary perceptual test with healthy subjects in static condition was carried out and the results indicated over 98% accuracy in determining stimuli location around the upper leg region, suggesting good perceptibility of the delivered stimuli

    Real-time gait event detection for transfemoral amputees during ramp ascending and descending

    Get PDF
    Events and phases detection of the human gait are vital for controlling prosthesis, orthosis and functional electrical stimulation (FES) systems. Wearable sensors are inexpensive, portable and have fast processing capability. They are frequently used to assess spatio-temporal, kinematic and kinetic parameters of the human gait which in turn provide more details about the human voluntary control and ampute-eprosthesis interaction. This paper presents a reliable real-time gait event detection algorithm based on simple heuristics approach, applicable to signals from tri-axial gyroscope for lower limb amputees during ramp ascending and descending. Experimental validation is done by comparing the results of gyroscope signal with footswitches. For healthy subjects, the mean difference between events detected by gyroscope and footswitches is 14 ms and 10.5 ms for initial contact (IC) whereas for toe off (TO) it is -5 ms and -25 ms for ramp up and down respectively. For transfemoral amputee, the error is slightly higher either due to the placement of footswitches underneath the foot or the lack of proper knee flexion and ankle plantarflexion/dorsiflexion during ramp up and down. Finally, repeatability tests showed promising results

    A Real-Time Gait Event Detection for Lower Limb Prosthesis Control and Evaluation

    Get PDF
    Lower extremity amputees suffer from mobility limitations which will result in a degradation of their quality of life. Wearable sensors are frequently used to assess spatio-temporal, kinematic and kinetic parameters providing the means to establish an interactive control of the amputee-prosthesis-environment system. Gait events and the gait phase detection of an amputeeโ€™s locomotion are vital for controlling lower limb prosthetic devices. The paper presents an approach to real-time gait event detection for lower limb amputees using a wireless gyroscope attached to the shank when performing level ground and ramp activities. The results were validated using both healthy and amputee subjects and showed that the time differences in identifying Initial Contact (IC) and Toe Off (TO) events were larger in a transfemoral amputee when compared to the control subjects and a transtibial amputee (TTA). Overall, the time difference latency lies within a range of ยฑ 50 ms while the detection rate was 100% for all activities. Based on the validated results, the IC and TO events can be accurately detected using the proposed system in both control subjects and amputees when performing activities of daily living and can also be utilized in the clinical setup for rehabilitation and assessing the performance of lower limb prosthesis users

    Estimation of Actuation System Parameters for Lower Limb Prostheses

    Get PDF
    This paper provides guidelines to estimate the kinematics, energy and torque requirements for lower limb prosthetic actuation systems during daily living activities. These parameters are estimated based on human biomechanical data from different sources to consider the variability due to the assumptions and errors in the analysis and data collection. The results showed that the powered actuation source is important at the ankle joint in the stance phase during level ground walking while it is more important at knee joint during stair ascending. These estimated parameters can be used as guidelines to design and select proper actuation systems

    Investigation into Energy Efficiency and Regeneration in an Electric Prosthetic Knee

    No full text
    Powered lower limb prosthesis are facing energy and efficiency challenges. This article presents an investigation into reducing the energy losses and increasing the efficiencies of energy regeneration for a powered prosthetic knee during level ground walking. The results showed that the regeneration and overall system efficiencies would dramatically increase if the negative mechanical load in the braking quadrants are within the regenerative zone of the motor. This approach reduced the energy losses in the stance and swing phases and increased the possibility of harvesting more negative mechanical energy during level ground walking

    Real-time gait event detection for lower limb amputees using a single wearable sensor

    Get PDF
    This paper presents a rule-based real-time gait event/phase detection system (R-GEDS) using a shank mounted inertial measurement unit (IMU) for lower limb amputees during the level ground walking. Development of the algorithm is based on the shank angular velocity in the sagittal plane and linear acceleration signal in the shank longitudinal direction. System performance was evaluated with four control subjects (CS) and one transfemoral amputee (TFA) and the results were validated with four FlexiForce footswitches (FSW). The results showed a data latency for initial contact (IC) and toe off (TO) within a range of ยฑ 40 ms for both CS and TFA. A delay of about 3.7 ยฑ 62 ms for a foot-flat start (FFS) and an early detection of -9.4 ยฑ 66 ms for heel-off (HO) was found for CS. Prosthetic side showed an early detection of -105 ยฑ 95 ms for FFS whereas intact side showed a delay of 141 ยฑ73 ms for HO. The difference in the kinematics of the TFA and CS is one of the potential reasons for high variations in the time difference. Overall, detection accuracy was 99.78% for all the events in both groups. Based on the validated results, the proposed system can be used to accurately detect the temporal gait events in real-time that leads to the detection of gait phase system and therefore, can be utilized in gait analysis applications and the control of lower limb prostheses
    corecore