174 research outputs found

    Two stage fracture of a polyethylene post in a 9-year-old posterior-stabilized knee prosthesis: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Several cases of tibial post breakage are reported in the literature. To the best of our knowledge, only three cases of NexGen knee prosthesis (Zimmer, Warsaw, Indiana, USA) tibial post failure have been reported.</p> <p>Case presentation</p> <p>In November 1999, a 63-year-old Caucasian woman from Italy with a history of symptomatic left knee osteoarthritis underwent a total knee arthroplasty. In March 2008, while rising from a chair, she felt a sudden pain and instability in her left knee. She reported a fracture of the polyethylene post of the tibial insert. No malposition or malalignment of either the femoral or tibial components were identified. The polyethylene tibial insert was studied under light microscopy and scanning electron microscopy. The fracture was also noted to have occurred without any notable polyethylene wear.</p> <p>Conclusion</p> <p>Scanning electron microscopy revealed two different damage patterns that could be explained with a two-stage rupture of our patient's polyethylene post. This could have been caused by a non-optimal ligamentous balancing during first implant surgery. Her knee probably developed a varus instability that weakened the post, and then a posterior anterior stress finally broke the polyethylene.</p

    Fifteen Year Outcome of the Ceraver Hermes Posterior-Stabilized Total Knee Arthroplasty: Safety of the Procedure with Experienced and Inexperienced Surgeons

    Get PDF
    We wished to determine whether total knee replacement (TKA) performed by young surgeons increased rates of mortality and complications compared with TKA performed by senior surgeons using the same model of arthroplasty. There were no significant pre-operative differences between the groups in terms of age, gender, height, weight, body mass index, diagnosis, comorbidity and duration of follow-up, which was a mean of 15 years in both groups. Hence, we assessed the 15 year survival of the first 150 Ceraver Posterior-Stabilized total knee arthroplasties undertaken by young surgeons (aged of less than 30 years) in formation in a single university hospital setting (Group B). We used survival curve analysis, with strict definitions regarding end-points, and evaluated a number of different endpoint criteria to assess the outcome and to compare the results with those obtained by the two seniors (aged of more than 40 years) with their 50 first implantations (Group A). The clinical results and survival rate of implants at intermediate to long-term follow-up were similar in both Groups. Kaplan-Meier survival analysis, with revision as the endpoint for failure, showed that the rate of survival at ten years was 96% (95% CI, 93 to 100) in both groups. At fifteen years the rate of survival was 91% (95% CI, 85 to 97) in group B, and 92% (95% CI, 90 to 94) in group A. The implant used in this series appears particularly safe since the usual complications observed with posterior stabilized arthroplasties were not observed even with young surgeons

    Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>As longevity of cementless femoral components enters the third decade, concerns arise with long-term effects of fixation mode on femoral bone morphology. We examined the long-term consequences on femoral remodeling following total hip arthroplasty with a porous plasma-sprayed tapered titanium stem.</p> <p>Methods</p> <p>Clinical data and radiographs were reviewed from a single center for 97 randomly selected cases implanted with the Mallory-Head Porous femoral component during primary total hip arthroplasty. Measurements were taken from preoperative and long-term follow-up radiographs averaging 14 years postoperative. Average changes in the proximal, middle and diaphyseal zones were determined.</p> <p>Results</p> <p>On anteroposterior radiographs, the proximal cortical thickness was unchanged medially and the lateral zone increased 1.3%. Middle cortical thickness increased 4.3% medially and 1.2% laterally. Distal cortical thickness increased 9.6% medially and 1.9% laterally. Using the anteroposterior radiographs, canal fill at 100 mm did not correlate with bony changes at any level (Spearman's rank correlation coefficient of -0.18, 0.05, and 0.00; p value = 0.09, 0.67, 0.97). On lateral radiographs, the proximal cortical thickness increased 1.5% medially and 0.98% laterally. Middle cortical thickness increased 2.4% medially and 1.3% laterally. Distal cortical thickness increased 3.5% medially and 2.1% laterally. From lateral radiographs, canal fill at 100 mm correlated with bony hypertrophy at the proximal, mid-level, and distal femur (Spearman's rank correlation coefficient of 0.85, 0.33, and 0.28, respectively; p value = 0.001, 0.016, and 0.01, respectively).</p> <p>Conclusion</p> <p>Stress shielding is minimized with the Mallory-Head titanium tapered femoral stem with circumferential proximal plasma-sprayed coating in well-fixed and well-functioning total hip arthroplasty. Additionally, the majority of femora demonstrated increased cortical thickness in all zones around the stem prosthesis. Level of Evidence: Therapeutic Level III.</p

    Damages of the tibial post in constrained total knee prostheses in the early postoperative course – a scanning electron microscopic study of polyethylene inlays

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Investigation of the risk of fracture of the polyethylene (PE) inlay in constrained total knee prostheses.</p> <p>Methods</p> <p>Three unused and seven polyethylene inlays that had been implanted in a patient's knee for an average of 25.4 months (min 1.1 months, max 50.2 months) were investigated using scanning electron microscopy (SEM). All inlays were of the same type and size (Genesis II constrained, Smith & Nephew). The PE surface at the transition from the plateau to the post was analyzed.</p> <p>Results</p> <p>The unused inlays had fissure-free surfaces. All inlays that had been implanted in a patient's knee already had distinct fissures at the front and backside of the post.</p> <p>Conclusion</p> <p>The fissures of the transition from the plateau to the post indicated a loading-induced irreversible mechanical deformation and possibly cause the fracture of the inlay.</p

    Use of antibiotic spacers for knee endoprosthesis infections treatment

    Get PDF
    OBJCTIVE: The aim of this study is to evaluate the use of cement spacers impregnated with antibiotics for the treatment of infections in the nonconventional endoprostheses of the knee. METHODOLOGY: We have treated seven patients since 2004 (of which six were submitted to surgery in our service and one patient had been submitted to a primary tumor surgery in another removal service) with deep infection in knee tumor prosthesis. All patients were submitted to endoprosthesis removal and reconstructed with antibiotic cement spacer. All patients were monitored both clinically and by lab tests as for monitoring the evolution, being considered able for reviews after 6 (six) months without infections signs. RESULTS: We have noted a small predominance of infectious processes on the prosthesis inserted on proximal tibia as compared with distal femur (57.1% x 42.9%). The mean follow-up time of patients was 68.2 months. During the follow up, one patient died as a result of the root disease. Six patients out of seven were regarded as cured and one persisted with infection signs and symptoms. CONCLUSION: The results obtained up to date have motivated us to continue using this method of treatment.OBJETIVO: O objetivo do estudo é avaliar a utilização dos espaçadores de cimento acrílico com antibiótico no tratamento das infecções em endopróteses não convencionais de joelho. MÉTODO: Desde de 2004 foram tratados sete pacientes (seis pacientes operados no nosso serviço e um paciente que havia sido submetido a cirurgia primária do tumor em outro serviço) com infecção peri-endoprótese não convencional de joelho. Todos pacientes foram submetidos a retirada da endoprótese e reconstrução com espaçador com cimento acrílico com antibiótico. Todos os pacientes foram monitorados clínica e laboratorialmente quanto ao controle da evolução, sendo considerados aptos para a revisão e recolocação de endoprótese após 06 (seis) meses sem sinais infecciosos RESULTADOS: Notamos um discreto predomínio do do processo infeccioso nas próteses realizadas na tíbia proximal em comparação com o fêmur distal (57,1% x 42,9%). O seguimento médio dos pacientes foi 68,2 meses. Durante o seguimento, um paciente faleceu devido a doença de base. Dos sete pacientes, 6 foram considerados curados e um persistiu com sinais e sintomas de infecção. CONCLUSÃO: Os resultados obtidos até o momento tem motivado a continuidade deste método de tratamento.Universidade Federal de São Paulo (UNIFESP) Escola Paulista de Medicina Departamento de Ortopedia e TraumatologiaUNIFESP, EPM, Depto. de Ortopedia e TraumatologiaSciEL

    The Evolution of Compact Binary Star Systems

    Get PDF
    We review the formation and evolution of compact binary stars consisting of white dwarfs (WDs), neutron stars (NSs), and black holes (BHs). Binary NSs and BHs are thought to be the primary astrophysical sources of gravitational waves (GWs) within the frequency band of ground-based detectors, while compact binaries of WDs are important sources of GWs at lower frequencies to be covered by space interferometers (LISA). Major uncertainties in the current understanding of properties of NSs and BHs most relevant to the GW studies are discussed, including the treatment of the natal kicks which compact stellar remnants acquire during the core collapse of massive stars and the common envelope phase of binary evolution. We discuss the coalescence rates of binary NSs and BHs and prospects for their detections, the formation and evolution of binary WDs and their observational manifestations. Special attention is given to AM CVn-stars -- compact binaries in which the Roche lobe is filled by another WD or a low-mass partially degenerate helium-star, as these stars are thought to be the best LISA verification binary GW sources.Comment: 105 pages, 18 figure

    Stiffness in total knee arthroplasty

    Get PDF
    Stiffness is a relatively uncommon complication after total knee arthroplasty. It has been defined as a painful limitation in the range of movement (ROM). Its pathogenesis is still unclear even if some risk factors have been identified. Patient-related conditions may be difficult to treat. Preoperative ROM is the most important risk factor, but an association with diabetes, reflex sympathetic dystrophy, and general pathologies such as juvenile rheumatoid arthritis and ankylosing spondylitis has been demonstrated. Moreover, previous surgery may be an additional cause of an ROM limitation. Postoperative factors include infections, arthrofibrosis, heterotrophic ossifications, and incorrect rehabilitation protocol. Infections represent a challenging problem for the orthopaedic surgeon, and treatment may require long periods of antibiotics administration. However, it is widely accepted that an aggressive rehabilitation protocol is mandatory for a proper ROM recovery and to avoid the onset of arthrofibrosis and heterotrophic ossifications. Finally, surgery-related factors represent the most common cause of stiffness; they include errors in soft-tissue balancing, component malpositioning, and incorrect component sizing. Although closed manipulation, arthroscopic and open arthrolysis have been proposed, they may lead to unpredictable results and incomplete ROM recovery. Revision surgery must be proposed in the case of well-documented surgical errors. These operations are technically demanding and may be associated with high risk of complications; therefore they should be accurately planned and properly performed
    corecore