1,465 research outputs found

    Molecular microbial ecology of lignocellulose mobilisation as a carbon source in mine drainage wastewater treatment

    Get PDF
    The community structure of complex microbial consortia which develop in lignocellulose packed passive treatment systems for acid mine drainage remediation were investigated. An understanding of interactions between these populations is important in determining mechanisms by which such systems operate. A degrading packed bed reactor was packed with lignocellulositic material as a sole carbon source and fed continuously with simulated acid mine drainage. Samples were collected every two months at different depths of the reactor to isolate the total genomic DNA and PCR amplify section of 16S rDNA gene. PCR primers, GM5F and 907R incorporating GC clamp were used to amplify 586-bp region of 16S rDNA gene. Denaturing gradient gel electrophoresis (DGGE) indicated clearly a highly differentiated pattern of r-DNA – derived amplificates between different depths of the bioreactor. Predominant DGGE bands were further excised, reamplified, cloned and sequenced. Sequencing analysis revealed phylogenetic affiliation of specific bacterial populations in different depths of the bioreactor. Water SA Vol. 30 (5) 2005: pp.658-66

    Classification of fibroglandular tissue distribution in the breast based on radiotherapy planning CT

    Get PDF
    Accurate segmentation of breast tissues is required for a number of applications such as model based deformable registration in breast radiotherapy. The accuracy of breast tissue segmentation is affected by the spatial distribution (or pattern) of fibroglandular tissue (FT). The goal of this study was to develop and evaluate texture features, determined from planning computed tomography (CT) data, to classify the spatial distribution of FT in the breas

    Voluntary versus ABC breath-hold in the context of VMAT for breast and locoregional lymph node radiotherapy including the internal mammary chain

    Get PDF
    Background: Deep-inspiration breath-hold (DIBH) reduces radiation dose to the heart in patients undergoing locoregional breast radiotherapy. In the context of tangential irradiation of the breast/ chest wall, a voluntary breath hold (vDIBH) technique has been shown to be as reproducible as a machine-assisted breath hold technique using the active breathing co-ordinator (ABCTM, Elekta, Crawley, UK, ABC_DIBH). This study compares set-up reproducibility for vDIBH versus ABC_DIBH in patients undergoing volumetric-modulated arc radiotherapy (VMAT) for breast cancer, both with and without wax bolus. Method: Patients with breast cancer requiring pan regional lymph node VMAT +/� wax bolus in breathhold were CT scanned in vDIBH and ABC_DIBH. Patients were randomised to receive one technique for fractions 1–7 and the other for fractions 8–15. Daily cone beam computed tomography (CBCT) was performed and registered to planning-CT using bony anatomy. Within-patient comparisons of mean daily chest wall position were made using a paired t-test. Population, systematic (P) and random errors (a) were estimated. Intrafraction reproducibility was assessed by comparing chest wall position and diaphragm movement between consecutive breath holds on CBCT. Results: 16 patients were recruited. All completed treatment with both techniques (9 patients with wax bolus, 7 patients without). CBCT derived P were 2.1–6.4 mm (ABC_DIBH) and 2.1–4.9 mm (vDIBH), a were 1.7–2.6 mm (ABC_DIBH) and 2.2–2.7 mm (vDIBH) and mean daily chest wall displacements (MD) were 0.0–1.5 mm (ABC_DIBH) and - 0.1–1.6 vDIBH (all p non-significant). Chest wall and diaphragm position was equivalent between consecutive breath holds in ABC and vDIBH (median difference 1.0 mm and 0.8 mm respectively, non p significant) demonstrating equivalent intrafraction reproducibility. Conclusion: This study demonstrates that a simple voluntary breath hold technique is feasible in combination with VMAT (+/� bolus) and is as reproducible as ABC_DIBH with VMAT for the irradiation of the breast and axillary and IMC lymph nodes in breast cancer patients

    A randomized control trial evaluating fluorescent ink versus dark ink tattoos for breast radiotherapy.

    Get PDF
    OBJECTIVE: The purpose of this UK study was to evaluate interfraction reproducibility and body image score when using ultraviolet (UV) tattoos (not visible in ambient lighting) for external references during breast/chest wall radiotherapy and compare with conventional dark ink. METHODS: In this non-blinded, single-centre, parallel group, randomized control trial, patients were allocated to receive either conventional dark ink or UV ink tattoos using computer-generated random blocks. Participant assignment was not masked. Systematic (∑) and random (σ) setup errors were determined using electronic portal images. Body image questionnaires were completed at pre-treatment, 1 month and 6 months to determine the impact of tattoo type on body image. The primary end point was to determine that UV tattoo random error (σsetup) was no less accurate than with conventional dark ink tattoos, i.e. <2.8 mm. RESULTS: 46 patients were randomized to receive conventional dark or UV ink tattoos. 45 patients completed treatment (UV: n = 23, dark: n = 22). σsetup for the UV tattoo group was <2.8 mm in the u and v directions (p = 0.001 and p = 0.009, respectively). A larger proportion of patients reported improvement in body image score in the UV tattoo group compared with the dark ink group at 1 month [56% (13/23) vs 14% (3/22), respectively] and 6 months [52% (11/21) vs 38% (8/21), respectively]. CONCLUSION: UV tattoos were associated with interfraction setup reproducibility comparable with conventional dark ink. Patients reported a more favourable change in body image score up to 6 months following treatment. Advances in knowledge: This study is the first to evaluate UV tattoo external references in a randomized control trial

    Pre-operative Radiotherapy And Deep Inferior Epigastric Artery Perforator (DIEP) flAp study (PRADA): Aesthetic outcome and patient satisfaction at one year.

    Get PDF
    INTRODUCTION: The optimal combination of radiotherapy and breast reconstruction has not yet been defined. Post-mastectomy radiotherapy (PMRT) has deleterious effects on breast reconstruction, leading to caution amongst surgeons. Pre-operative radiotherapy (PRT) is a growing area of interest, is demonstrated to be safe, and spares autologous flaps from radiotherapy. This study evaluates the aesthetic outcome of PRT and deep inferior epigastric artery perforator (DIEP) flap reconstruction within the Pre-operative Radiotherapy And Deep Inferior Epigastric artery Perforator (DIEP) flAp (PRADA) cohort. METHODS: PRADA was an observational cohort study designed to evaluate the feasibility and safety of PRT for women undergoing neoadjuvant chemotherapy and DIEP reconstruction. Panel evaluation of 3D surface images (3D-SIs) and patient-reported outcome measures (BREAST-Q) for a subset of women in the study were compared with those of a DIEP-PMRT cohort who had undergone DIEP reconstruction and PMRT. RESULTS: Seventeen out of 33 women from the PRADA study participated in this planned substudy. Twenty-eight women formed the DIEP-PMRT cohort (median follow-up 23 months). The median (inter-quartile range [IQR]) 'satisfaction with breasts' score at 12 months for the PRADA cohort was significantly better than the DIEP-PMRT cohort (77 [72-87] versus 64 [54-71], respectively), p=0.01). Median [IQR] panel evaluation (5-point scale) was also significantly better for the PRADA cohort than for the DIEP-PMRT cohort (4.3 [3.9-4.6] versus 3.6 [2.8-4] p=0.003). CONCLUSIONS: Aesthetic outcome for the PRADA cohort was reported to be 'good' or 'excellent' in 93% of cases using a bespoke panel assessment with robust methodology. Patient satisfaction at one year is encouraging and superior to DIEP-PMRT at 23 months. Switching surgery-radiotherapy sequencing leads to similar breast aesthetic outcomes and warrants further large-scale, multi-centre evaluation in a randomised trial

    A cross-machine comparison of shear-wave speed measurements using 2d shear-wave elastography in the normal female breast

    Get PDF
    Quantitative measures of radiation-induced breast stiffness are required to support clinical studies of novel breast radiotherapy regimens and exploration of personalised therapy, however, variation between shear-wave elastography (SWE) machines may limit the usefulness of shear-wave speed (cs) for this purpose. Mean cs measured in four healthy volunteers’ breasts and a phantom using 2D-SWE machines Acuson S2000 (Siemens Medical Solutions) and Aixplorer (Supersonic Imagine) were compared. Shear-wave speed was measured in the skin region, subcutaneous adipose tissue and parenchyma. cs estimates were on average 2.3% greater when using the Aixplorer compared to S2000 in vitro. In vivo, cs estimates were on average 43.7%, 36.3% and 49.9% significantly greater (p &lt;&lt; 0.01) when using the Aixplorer compared to S2000, for skin region, subcutaneous adipose tissue and parenchyma, respectively. In conclusion, despite relatively small differences between machines observed in vitro, large differences in absolute measures of shear wave speed measured were observed in vivo, which may prevent pooling of cross-machine data in clinical studies of the breast.</jats:p

    Mean heart dose variation over a course of breath-holding breast cancer radiotherapy.

    Get PDF
    Objective The purpose of the work was to estimate the dose received by the heart throughout a course of breath-holding breast radiotherapy.Methods 113 cone-beam CT (CBCT) scans were acquired for 20 patients treated within the HeartSpare 1A study, in which both an active breathing control (ABC) device and a voluntary breath-hold (VBH) method were used. Predicted mean heart doses were obtained from treatment plans. CBCT scans were imported into a treatment planning system, heart outlines defined, images registered to the CT planning scan and mean heart dose recorded. Two observers outlined two cases three times each to assess interobserver and intraobserver variation.Results There were no statistically significant differences between ABC and VBH heart dose data from CT planning scans, or in the CBCT-based estimates of heart dose, and no effect from the order of the breath-hold method. Variation in mean heart dose per fraction over the three imaged fractions was <6 cGy without setup correction, decreasing to 3.3 cGy with setup correction. If scaled to 15 fractions, all differences between predicted and estimated mean heart doses were <0.5 Gy and in 80% of cases, they were <0.25 Gy.Conclusion Variation in mean heart dose was at an acceptable level over the duration of breath-holding radiotherapy and was well predicted by the planning system. Advances in knowledge: Mean heart dose was not adversely affected by fraction-to-fraction variations throughout a course of heart-sparing radiotherapy using two well-established breath-holding methods

    Hitting the Target: Developing High-quality Evidence for Proton Beam Therapy Through Randomised Controlled Trials

    Get PDF
    The National Health Service strategy for the delivery of proton beam therapy (PBT) in the UK provides a unique opportunity to deliver high-quality evidence for PBT through randomised controlled trials (RCTs). We present a summary of three UK PBT RCTs in progress, including consideration of their key design characteristics and outcome assessments, to inform and support future PBT trial development. The first three UK multicentre phase III PBT RCTs (TORPEdO, PARABLE and APPROACH), will compare PBT with photon radiotherapy for oropharyngeal squamous cell carcinoma, breast cancer and oligodendroglioma, respectively. All three studies were designed by multidisciplinary teams, which combined expertise from clinicians, clinical trialists and scientists with strong patient advocacy and guidance from national radiotherapy research networks and international collaborators. Consistent across all three studies is a focus on the reduction of long-term radiotherapy-related toxicities and an evaluation of patient-reported outcomes and health-related quality of life, which will address key uncertainties regarding the clinical benefits of PBT. Innovative translational components will provide insights into mechanisms of toxicity and help to frame the key future research questions regarding PBT. The UK radiotherapy research community is developing and delivering an internationally impactful PBT research portfolio. The combination of data from RCTs with prospectively collected data from a national PBT outcomes registry will provide an innovative, high-quality repository for PBT research and the platform to design and deliver future trials of PBT

    Can patient decision aids reduce decisional conflict in a de-escalation of breast radiotherapy clinical trial? The PRIMETIME Study Within a Trial implemented using a cluster stepped-wedge trial design

    Get PDF
    Background For patients with early breast cancer considered at very-low risk of local relapse, risks of radiotherapy may outweigh the benefits. Decisions regarding treatment omission can lead to patient uncertainty (decisional conflict), which may be lessened with patient decision aids (PDA). PRIMETIME (ISRCTN 41579286) is a UK-led biomarker-directed study evaluating omission of adjuvant radiotherapy in breast cancer; an embedded Study Within A Trial (SWAT) investigated whether PDA reduces decisional conflict using a cluster stepped-wedge trial design.Methods PDA diagrams and a video explaining risks and benefits of radiotherapy were developed in close collaboration between patient advocates and PRIMETIME trialists. The SWAT used a cluster stepped-wedge trial design, where each cluster represented the radiotherapy centre and referring peripheral centres. All clusters began in the standard information group (patient information and diagrams) and were randomised to cross-over to the enhanced information group (standard information plus video) at 2, 4 or 6 months. Primary endpoint was the decisional conflict scale (0-100, higher scores indicating greater conflict) which was assessed on an individual participant level. Multilevel mixed effects models used a random effect for cluster and a fixed effect for each step to adjust for calendar time and clustering. Robust standard errors were also adjusted for the clustering effect.Results Five hundred twenty-one evaluable questionnaires were returned from 809 eligible patients (64%) in 24 clusters between April 2018 and October 2019. Mean decisional conflict scores in the standard group (N = 184) were 10.88 (SD 11.82) and 8.99 (SD 11.82) in the enhanced group (N = 337), with no statistically significant difference [mean difference - 1.78, 95%CI - 3.82-0.25, p = 0.09]. Compliance with patient information and diagrams was high in both groups although in the enhanced group only 121/337 (36%) reported watching the video.Conclusion The low levels of decisional conflict in PRIMETIME are reassuring and may reflect the high-quality information provision, such that not everyone required the video. This reinforces the importance of working with patients as partners in clinical trials especially in the development of patient-centred information and decision aids
    • …
    corecore