42 research outputs found

    Comparison of Replication-Competent, First Generation, and Helper-Dependent Adenoviral Vaccines

    Get PDF
    All studies using human serotype 5 Adenovirus (Ad) vectors must address two major obstacles: safety and the presence of pre-existing neutralizing antibodies. Helper-Dependent (HD) Ads have been proposed as alternative vectors for gene therapy and vaccine development because they have an improved safety profile. To evaluate the potential of HD-Ad vaccines, we compared replication-competent (RC), first-generation (FG) and HD vectors for their ability to induce immune responses in mice. We show that RC-Ad5 and HD-Ad5 vectors generate stronger immune responses than FG-Ad5 vectors. HD-Ad5 vectors gave lower side effects than RC or FG-Ad, producing lower levels of tissue damage and anti-Ad T cell responses. Also, HD vectors have the benefit of being packaged by all subgroup C serotype helper viruses. We found that HD serotypes 1, 2, 5, and 6 induce anti-HIV responses equivalently. By using these HD serotypes in heterologous succession we showed that HD vectors can be used to significantly boost anti-HIV immune responses in mice and in FG-Ad5-immune macaques. Since HD vectors have been show to have an increased safety profile, do not possess any Ad genes, can be packaged by multiple serotype helper viruses, and elicit strong anti-HIV immune responses, they warrant further investigation as alternatives to FG vectors as gene-based vaccines

    Prevalence of ocular abnormalities in adults with Down syndrome in Hong Kong

    No full text
    Background/Aims: This was a cross-sectional survey to find the prevalence of visual impairment and eye diseases among adults with Down syndrome (DS) in Hong Kong. Methods: 91 DS patients over the age of 30 were recruited through the Hong Kong Down Syndrome Association. Each patient was provided with a complete ophthalmological assessment including best corrected visual acuity, refraction, slit lamp and fundus examination. Results: In our sample, 56.6% had normal vision to mild vision impairment, 33.7% and 7.2% had moderate and severe vision impairment, respectively, and 2.4% were blind. The mean presenting distant LogMAR visual acuity was 0.66 (Snellen equivalent 20/90), and the best corrected LogMAR visual acuity was 0.48 (Snellen equivalent 20/60). Significant refractive errors were found in 86.3% of the eyes, with spherical equivalent corrections ranging from -23.25D to +3.00D. Myopia and astigmatism were prevalent and found in 59.3% and 72.7% of the eyes, respectively. Blepharitis and chalazion were found in 44% of the eyes, while corneal problems were present in 27.5%. There were low incidences of infective keratitis (0.5%), keratoconus (0.5%) and Brushfield spots (1.1%). Cataracts were found in 72.2% of the eyes; 26.1% were congenital and 44.9% were age-related. Fundal abnormalities were present in 49.5% of the eyes. Conclusions: There is a high prevalence of vision impairment among Chinese DS adults. Uncorrected refractive errors, high myopia and cataracts are the main visually debilitating ophthalmological abnormalities. Vision may be improved through the simple use of glasses and early treatment of age-related cataracts.link_to_subscribed_fulltex

    Apparatus and method for identifying object movement and location with RFID device

    No full text
    Latest registration information, etc. at Hong Kong IPD websiteInventor name used in this publication: Cheung Chi FaiInventor name used in this publication: Tsang Hing ChoiInventor name used in this publication: Lee Wing BunHK1095991; HK1095991A; HK1095991 A; 1095991A; Application No. 07100834.3Hong KongVersion of Recor

    Analysing optimisation data for multicriteria building spatial design

    No full text
    Domain experts can benefit from optimisation simply by getting better solutions, or by obtaining knowledge about possible trade-offs from a Pareto front. However, just providing a better solution based on objective function values is often not sufficient. It is desirable for domain experts to understand design principles that lead to a better solution concerning different objectives. Such insights will help the domain expert to gain confidence in a solution provided by the optimiser. In this paper, the aim is to learn heuristic rules on building spatial design by data-mining multi-objective optimisation results. From the optimisation data a domain expert can gain new insights that can help engineers in the future; this is termed innovization. Originally used for applications in mechanical engineering, innovization is here applied for the first time for optimisation of building spatial designs with respect to thermal and structural performance

    A fidget spinner for the point-of-care diagnosis of urinary tract infection

    No full text
    The point-of-care detection of pathogens in biological samples in resource-limited settings should be inexpensive, rapid, portable, simple and accurate. Here, we describe a custom-made fidget spinner that rapidly concentrates pathogens in 1-ml samples of undiluted urine by more than 100-fold for the on-device colorimetric detection of bacterial load and pathogen identification. In Tiruchirappalli, India, the device enabled the on-site detection of infection with the naked eye within 50 min in urine samples from 39 patients suspected of having a urinary tract infection. We also show that, in 30 clinical samples of urinary tract infection, the device can be used to perform an antimicrobial susceptibility test for the antimicrobial drugs ciprofloxacin and cefazolin within 120 min. The fidget spinner could be used in low-resource settings as an inexpensive handheld point-of-care device for the rapid concentration and detection of pathogens in urine samples. A custom-made fidget spinner rapidly concentrates pathogens in 1-ml samples of undiluted urine by more than 100-fold for the on-device colorimetric detection of bacterial load and pathogen identification

    Key Parameters of Tumor Epitope Immunogenicity Revealed Through a Consortium Approach Improve Neoantigen Prediction.

    No full text
    Many approaches to identify therapeutically relevant neoantigens couple tumor sequencing with bioinformatic algorithms and inferred rules of tumor epitope immunogenicity. However, there are no reference data to compare these approaches, and the parameters governing tumor epitope immunogenicity remain unclear. Here, we assembled a global consortium wherein each participant predicted immunogenic epitopes from shared tumor sequencing data. 608 epitopes were subsequently assessed for T cell binding in patient-matched samples. By integrating peptide features associated with presentation and recognition, we developed a model of tumor epitope immunogenicity that filtered out 98% of non-immunogenic peptides with a precision above 0.70. Pipelines prioritizing model features had superior performance, and pipeline alterations leveraging them improved prediction performance. These findings were validated in an independent cohort of 310 epitopes prioritized from tumor sequencing data and assessed for T cell binding. This data resource enables identification of parameters underlying effective anti-tumor immunity and is available to the research community
    corecore