311 research outputs found

    The revision partial knee classification system: understanding the causative pathology and magnitude of further surgery following partial knee arthroplasty.

    Get PDF
    AIMS: Joint registries classify all further arthroplasty procedures to a knee with an existing partial arthroplasty as revision surgery, regardless of the actual procedure performed. Relatively minor procedures, including bearing exchanges, are classified in the same way as major operations requiring augments and stems. A new classification system is proposed to acknowledge and describe the detail of these procedures, which has implications for risk, recovery, and health economics. METHODS: Classification categories were proposed by a surgical consensus group, then ranked by patients, according to perceived invasiveness and implications for recovery. In round one, 26 revision cases were classified by the consensus group. Results were tested for inter-rater reliability. In round two, four additional cases were added for clarity. Round three repeated the survey one month later, subject to inter- and intrarater reliability testing. In round four, five additional expert partial knee arthroplasty surgeons were asked to classify the 30 cases according to the proposed revision partial knee classification (RPKC) system. RESULTS: Four classes were proposed: PR1, where no bone-implant interfaces are affected; PR2, where surgery does not include conversion to total knee arthroplasty, for example, a second partial arthroplasty to a native compartment; PR3, when a standard primary total knee prosthesis is used; and PR4 when revision components are necessary. Round one resulted in 92% inter-rater agreement (Kendall's W 0.97; p < 0.005), rising to 93% in round two (Kendall's W 0.98; p < 0.001). Round three demonstrated 97% agreement (Kendall's W 0.98; p < 0.001), with high intra-rater reliability (interclass correlation coefficient (ICC) 0.99; 95% confidence interval 0.98 to 0.99). Round four resulted in 80% agreement (Kendall's W 0.92; p < 0.001). CONCLUSION: The RPKC system accounts for all procedures which may be appropriate following partial knee arthroplasty. It has been shown to be reliable, repeatable and pragmatic. The implications for patient care and health economics are discussed. Cite this article: Bone Jt Open 2021;2(8):638-645

    How to prioritize patients and redesign care to safely resume planned surgery during the COVID-19 pandemic.

    Get PDF
    AIMS: Restarting planned surgery during the COVID-19 pandemic is a clinical and societal priority, but it is unknown whether it can be done safely and include high-risk or complex cases. We developed a Surgical Prioritization and Allocation Guide (SPAG). Here, we validate its effectiveness and safety in COVID-free sites. METHODS: A multidisciplinary surgical prioritization committee developed the SPAG, incorporating procedural urgency, shared decision-making, patient safety, and biopsychosocial factors; and applied it to 1,142 adult patients awaiting orthopaedic surgery. Patients were stratified into four priority groups and underwent surgery at three COVID-free sites, including one with access to a high dependency unit (HDU) or intensive care unit (ICU) and specialist resources. Safety was assessed by the number of patients requiring inpatient postoperative HDU/ICU admission, contracting COVID-19 within 14 days postoperatively, and mortality within 30 days postoperatively. RESULTS: A total of 1,142 patients were included, 47 declined surgery, and 110 were deemed high-risk or requiring specialist resources. In the ten-week study period, 28 high-risk patients underwent surgery, during which 68% (13/19) of Priority 2 (P2, surgery within one month) patients underwent surgery, and 15% (3/20) of P3 ( three months) groups. Of the 1,032 low-risk patients, 322 patients underwent surgery. Overall, 21 P3 and P4 patients were expedited to 'Urgent' based on biopsychosocial factors identified by the SPAG. During the study period, 91% (19/21) of the Urgent group, 52% (49/95) of P2, 36% (70/196) of P3, and 26% (184/720) of P4 underwent surgery. No patients died or were admitted to HDU/ICU, or contracted COVID-19. CONCLUSION: Our widely generalizable model enabled the restart of planned surgery during the COVID-19 pandemic, without compromising patient safety or excluding high-risk or complex cases. Patients classified as Urgent or P2 were most likely to undergo surgery, including those deemed high-risk. This model, which includes assessment of biopsychosocial factors alongside disease severity, can assist in equitably prioritizing the substantial list of patients now awaiting planned orthopaedic surgery worldwide. Cite this article: Bone Jt Open 2021;2(2):134-140

    Immersive virtual reality enables technical skill acquisition for scrub nurses in complex revision total knee arthroplasty.

    Get PDF
    INTRODUCTION: Immersive Virtual Reality (iVR) is a novel technology which can enhance surgical training in a virtual environment without supervision. However, it is untested for the training to select, assemble and deliver instrumentation in orthopaedic surgery-typically performed by scrub nurses. This study investigates the impact of an iVR curriculum on this facet of the technically demanding revision total knee arthroplasty. MATERIALS AND METHODS: Ten scrub nurses completed training in four iVR sessions over a 4-week period. Initially, nurses completed a baseline real-world assessment, performing their role with real equipment in a simulated operation assessment. Each subsequent iVR session involved a guided mode, where the software taught participants the procedural choreography and assembly of instrumentation in a simulated operating room. In the latter three sessions, nurses also undertook an assessment in iVR. Outcome measures were related to procedural sequence, duration of surgery and efficiency of movement. Transfer of skills from iVR to the real world was assessed in a post-training simulated operation assessment. A pre- and post-training questionnaire assessed the participants knowledge, confidence and anxiety. RESULTS: Operative time reduced by an average of 47% across the 3 unguided sessions (mean 55.5 ± 17.6 min to 29.3 ± 12.1 min, p > 0.001). Assistive prompts reduced by 75% (34.1 ± 16.8 to 8.6 ± 8.8, p < 0.001), dominant hand motion by 28% (881.3 ± 178.5 m to 643.3 ± 119.8 m, p < 0.001) and head motion by 36% (459.9 ± 99.7 m to 292.6 ± 85.3 m, p < 0.001). Real-world skill improved from 11% prior to iVR training to 84% correct post-training. Participants reported increased confidence and reduced anxiety in scrubbing for rTKA procedures (p < 0.001). CONCLUSIONS: For scrub nurses, unfamiliarity with complex surgical procedures or equipment is common. Immersive VR training improved their understanding, technical skills and efficiency. These iVR-learnt skills transferred into the real world

    Pseudotumors in association with well-functioning metal-on-metal hip prostheses: a case-control study using three-dimensional computed tomography and magnetic resonance imaging.

    Get PDF
    Many papers have been published recently on the subject of pseudotumors surrounding metal-on-metal hip resurfacing and replacement prostheses. These pseudotumors are sterile, inflammatory lesions within the periprosthetic tissues and have been variously termed masses, cysts, bursae, collections, or aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL). The prevalence of pseudotumors in patients with a well-functioning metal-on-metal hip prosthesis is not well known. The purpose of this study was to quantify the prevalence of pseudotumors adjacent to well-functioning and painful metal-on-metal hip prostheses, to characterize these lesions with use of magnetic resonance imaging, and to assess the relationship between their presence and acetabular cup position with use of three-dimensional computed tomography

    Collaborative team training in virtual reality is superior to individual learning for performing complex open surgery: a randomised controlled trial

    Get PDF
    Objective: To assess if multiplayer virtual reality (VR) training was superior to single player training for acquisition of both technical and non-technical skills in learning complex surgery. Summary Background Data: Superior team-work in the operating room (OR) is associated with improved technical performance and clinical outcomes. VR can successfully train OR staff individually, however VR team training has yet to be investigated. Method: Forty participants were randomised to individual or team VR training. Individually-trained participants practiced alongside virtual avatar counterparts, whilst teams trained live in pairs. Both groups underwent five VR training sessions over 6-weeks. Subsequently, they underwent a real-life assessment in which they performed Anterior Approach Total Hip Arthroplasty (AA-THA) surgery on a high-fidelity model with real equipment in a simulated OR. Teams performed together and individually-trained participants were randomly paired up. Videos were marked by two blinded assessors recording the NOTSS, NOTECHS II and SPLINTS scores. Secondary outcomes were procedure time and number of technical errors. Results: Teams outperformed individually-trained participants for non-technical skills in the real-world assessment (NOTSS 13.1±1.5 vs 10.6±1.6, P=0.002, NOTECHS-II score 51.7±5.5 vs 42.3±5.6, P=0.001 and SPLINTS 10±1.2 vs 7.9±1.6, P=0.004). They completed the assessment 28.1% faster (27.2 minutes±5.5 vs 41.8 ±8.9, P<0.001), and made fewer than half the number of technical errors (10.4±6.1 vs 22.6±5.4, P<0.001). Conclusions: Multiplayer training leads to faster surgery with fewer technical errors and the development of superior non-technical skills

    Continuing medical education challenges in chronic fatigue syndrome

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Chronic fatigue syndrome (CFS) affects at least 4 million people in the United States, yet only 16% of people with CFS have received a diagnosis or medical care for their illness. Educating health care professionals about the diagnosis and management of CFS may help to reduce population morbidity associated with CFS.</p> <p>Methods</p> <p>This report presents findings over a 5-year period from May 2000 to June 2006 during which we developed and implemented a health care professional educational program. The objective of the program was to distribute CFS continuing education materials to providers at professional conferences, offer online continuing education credits in different formats (e.g., print, video, and online), and evaluate the number of accreditation certificates awarded.</p> <p>Results</p> <p>We found that smaller conference size (OR = 80.17; 95% CI 8.80, 730.25), CFS illness related target audiences (OR = 36.0; 95% CI 2.94, 436.34), and conferences in which CFS research was highlighted (OR = 4.15; 95% CI 1.16, 14.83) significantly contributed to higher dissemination levels, as measured by visit rates to the education booth. While print and online courses were equally requested for continuing education credit opportunities, the online course resulted in 84% of the overall award certificates, compared to 14% for the print course. This remained consistent across all provider occupations: physicians, nurses, physician assistants, and allied health professionals.</p> <p>Conclusion</p> <p>These findings suggest that educational programs promoting materials at conferences may increase dissemination efforts by targeting audiences, examining conference characteristics, and promoting online continuing education forums.</p

    Developing nanotechnology in Latin America

    Get PDF
    This article investigates the development of nanotechnology in Latin America with a particular focus on Argentina, Brazil, Chile, and Uruguay. Based on data for nanotechnology research publications and patents and suggesting a framework for analyzing the development of R&D networks, we identify three potential strategies of nanotechnology research collaboration. Then, we seek to identify the balance of emphasis upon each of the three strategies by mapping the current research profile of those four countries. In general, we find that they are implementing policies and programs to develop nanotechnologies but differ in their collaboration strategies, institutional involvement, and level of development. On the other hand, we find that they coincide in having a modest industry participation in research and a low level of commercialization of nanotechnologies

    MICE: The muon ionization cooling experiment. Step I: First measurement of emittance with particle physics detectors

    Get PDF
    Copyright @ 2011 APSThe Muon Ionization Cooling Experiment (MICE) is a strategic R&D project intended to demonstrate the only practical solution to providing high brilliance beams necessary for a neutrino factory or muon collider. MICE is under development at the Rutherford Appleton Laboratory (RAL) in the United Kingdom. It comprises a dedicated beamline to generate a range of input muon emittances and momenta, with time-of-flight and Cherenkov detectors to ensure a pure muon beam. The emittance of the incoming beam will be measured in the upstream magnetic spectrometer with a scintillating fiber tracker. A cooling cell will then follow, alternating energy loss in Liquid Hydrogen (LH2) absorbers to RF cavity acceleration. A second spectrometer, identical to the first, and a second muon identification system will measure the outgoing emittance. In the 2010 run at RAL the muon beamline and most detectors were fully commissioned and a first measurement of the emittance of the muon beam with particle physics (time-of-flight) detectors was performed. The analysis of these data was recently completed and is discussed in this paper. Future steps for MICE, where beam emittance and emittance reduction (cooling) are to be measured with greater accuracy, are also presented.This work was supported by NSF grant PHY-0842798

    Menstrual irregularity and bone mass in premenopausal women: Cross-sectional associations with testosterone and SHBG

    Get PDF
    Background. There have been few studies examining the associations between menstrual irregularity, androgens and bone mass in population-based samples of premenopausal women. This study aimed to describe the associations between menstrual pattern, testosterone, sex hormone binding globulin (SHBG) and bone mass in a population-based sample of premenopausal women. Methods. Cross-sectional study (N = 382, mean age 31.5 years). Menstrual pattern was assessed by questionnaire, bone mass measured by quantitative ultrasound (QUS) and androgen status was assessed by levels of serum testosterone, SHBG and the free androgen index (FAI). Results. Women with irregular cycles (n = 41, 11%) had higher free androgen index (FAI, P = 0.01) and higher QUS measurements including speed of sound (SOS, 1%, P < 0.05), quantitative ultrasound index (QUI, 7%, p < 0.05), and broadband ultrasound attenuation (BUA, 7%, p = 0.10). These associations persisted after adjustment for age and body mass index (BMI). After further adjustment for hormonal factors (either testosterone, SHBG or FAI), the strength of the associations was moderately attenuated, however, women with irregular cycles still had a 6% increase in mean QUS. Total testosterone, FAI and SHBG were also associated with QUS measures (testosterone and FAI, r +0.11 to +0.21, all p < 0.05; SHBG r -0.14 to -0.16, all p < 0.05) and the associations remained significant after adjustment. Conclusion. Irregular menstrual cycles were associated with higher bone mass in this population-based sample of premenopausal women suggesting menstrual disturbance should continue to be evaluated but may be less harmful for bone mass. The association between menstrual irregularity and bone mass was partially mediated by markers of androgen status especially free testosterone

    First observations of separated atmospheric nu_mu and bar{nu-mu} events in the MINOS detector

    Get PDF
    The complete 5.4 kton MINOS far detector has been taking data since the beginning of August 2003 at a depth of 2070 meters water-equivalent in the Soudan mine, Minnesota. This paper presents the first MINOS observations of nuµ and [overline nu ]µ charged-current atmospheric neutrino interactions based on an exposure of 418 days. The ratio of upward- to downward-going events in the data is compared to the Monte Carlo expectation in the absence of neutrino oscillations, giving Rup/downdata/Rup/downMC=0.62-0.14+0.19(stat.)±0.02(sys.). An extended maximum likelihood analysis of the observed L/E distributions excludes the null hypothesis of no neutrino oscillations at the 98% confidence level. Using the curvature of the observed muons in the 1.3 T MINOS magnetic field nuµ and [overline nu ]µ interactions are separated. The ratio of [overline nu ]µ to nuµ events in the data is compared to the Monte Carlo expectation assuming neutrinos and antineutrinos oscillate in the same manner, giving R[overline nu ][sub mu]/nu[sub mu]data/R[overline nu ][sub mu]/nu[sub mu]MC=0.96-0.27+0.38(stat.)±0.15(sys.), where the errors are the statistical and systematic uncertainties. Although the statistics are limited, this is the first direct observation of atmospheric neutrino interactions separately for nuµ and [overline nu ]µ
    corecore