9 research outputs found

    Iridium oxide (IV) nanoparticle-based lateral flow immunoassay

    Get PDF
    Lateral flow biosensors are paper-based devices that allow the detection of different types of analytes with quickness, robustness and selectivity, without leaving behind paper sensors benefits as low-cost, recyclability and sustainability. Nanomaterials have been widely reported in lateral flow biosensors, offering new sensing strategies based on optical or electrical detection techniques. Looking for other advantageous nanomaterials, we propose for the first time the use of iridium oxide (IV) nanoparticles in lateral flow assays for the detection of human immunoglobulin as a model protein. These nanoparticles can be easily prepared and conjugated with biomarkers. Their dark blue color gives a high contrast against the white background of the strips being in this way excellent labels

    A novel ratiometric fluorescent approach for the modulation of the dynamic range of lateral flow immunoassays

    Get PDF
    The majority of lateral flow assays (LFAs) use single-color optical labels to provide a qualitative naked-eye detection, however this detection method displays two important limitations. First, the use of a single-color label makes the LFA prone to results misinterpretation. Second, it does not allow the precise modulation of the sensitivity and dynamic range of the test. To overcome these limitations, a ratiometric approach is developed. In particular, using anti-HIgG functionalized red-fluorescent quantum dots on the conjugate pad (as target dependent labels) and blue-fluorescent nanoparticles fixed on the test line (as target independent reporters), it is possible to generate a wide color palette (blue, purple, pink, red) on the test line. It is believed that this strategy will facilitate the development of LFAs by easily adjusting their analytical properties to the needs required by the specific application

    Intestinal fungi contribute to development of alcoholic liver disease

    Get PDF
    This study was supported in part by NIH grants R01 AA020703, U01 AA021856 and by Award Number I01BX002213 from the Biomedical Laboratory Research & Development Service of the VA Office of Research and Development (to B.S.). K.H. was supported by a DFG (Deutsche Forschungsgemeinschaft) fellowship (HO/ 5690/1-1). S.B. was supported by a grant from the Swiss National Science Foundation (P2SKP3_158649). G.G. received funding from the Yale Liver Center NIH P30 DK34989 and R.B. from NIAAA grant U01 AA021908. A.K. received support from NIH grants RC2 AA019405, R01 AA020216 and R01 AA023417. G.D.B. is supported by funds from the Wellcome Trust. We acknowledge the Human Tissue and Cell Research (HTCR) Foundation for making human tissue available for research and Hepacult GmbH (Munich, Germany) for providing primary human hepatocytes for in vitro analyses. We thank Dr. Chien-Yu Lin Department of Medicine, Fu-Jen Catholic University, Taiwan for statistical analysis.Peer reviewedPublisher PD

    Iridium oxide (IV) nanoparticle-based lateral flow immunoassay

    No full text
    Lateral flow biosensors are paper-based devices that allow the detection of different types of analytes with quickness, robustness and selectivity, without leaving behind paper sensors benefits as low-cost, recyclability and sustainability. Nanomaterials have been widely reported in lateral flow biosensors, offering new sensing strategies based on optical or electrical detection techniques. Looking for other advantageous nanomaterials, we propose for the first time the use of iridium oxide (IV) nanoparticles in lateral flow assays for the detection of human immunoglobulin as a model protein. These nanoparticles can be easily prepared and conjugated with biomarkers. Their dark blue color gives a high contrast against the white background of the strips being in this way excellent labels

    Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays

    No full text
    Lateral-flow assays (LFAs) are quick, simple and cheap assays to analyze various samples at the point of care or in the field, making them one of the most widespread biosensors currently available. They have been successfully employed for the detection of a myriad of different targets (ranging from atoms up to whole cells) in all type of samples (including water, blood, foodstuff and environmental samples). Their operation relies on the capillary flow of the sample throughout a series of sequential pads, each with different functionalities aiming to generate a signal to indicate the absence/presence (and, in some cases, the concentration) of the analyte of interest. To have a user-friendly operation, their development requires the optimization of multiple, interconnected parameters that may overwhelm new developers. In this tutorial, we provide the readers with: (i) the basic knowledge to understand the principles governing an LFA and to take informed decisions during lateral flow strip design and fabrication, (ii) a roadmap for optimal LFA development independent of the specific application, (iii) a step-by-step example procedure for the assembly and operation of an LF strip for the detection of human IgG and (iv) an extensive troubleshooting section addressing the most frequent issues in designing, assembling and using LFAs. By changing only the receptors, the provided example procedure can easily be adapted for cost-efficient detection of a broad variety of targets

    Abstracts of posters

    No full text
    corecore