14 research outputs found

    Evaluation of strand-to-strand capacitance and dissipation factor in thermally aged enamelled coils for low-voltage electrical machines

    Get PDF
    © The Institution of Engineering and Technology 2019. The dissipation factor (i.e. tanδ) and insulation capacitance (IC) measurements are conventional monitoring methods for assessing the aging level of insulation systems. These quantities provide an invaluable indication of the dielectric losses within the insulating materials. However, how these values are affected by the aging processes due to thermal stresses have until today never been investigated fully. Thus, this study exhibits the influence of thermal aging on tanδ and IC of windings for electrical machines (EMs). The work is performed for class 200, round enamelled magnet wire specimens. The study aims at improving the design process of EMs for short duty cycle applications; hence, its outcome might be included at the design stage for enhancing reliability and lifetime. Random wound coils are chosen in the performed study, because they are the most common winding arrangement for low-voltage EMs, which are employed in a wide range of applications (e.g. from home appliances to aerospace motors). Based on the collected data, considerations regarding the impact of relative humidity on both the dissipation factor and IC are presented. Finally, the correlation between the partial discharge inception voltage and the diagnostic measurements is experimentally verified

    Effect of a quality improvement program on compliance to the sepsis bundle in non-ICU patients: a multicenter prospective before and after cohort study

    Get PDF
    ObjectiveSepsis and septic shock are major challenges and economic burdens to healthcare, impacting millions of people globally and representing significant causes of mortality. Recently, a large number of quality improvement programs focused on sepsis resuscitation bundles have been instituted worldwide. These educational initiatives have been shown to be associated with improvements in clinical outcomes. We aimed to evaluate the impact of a multi-faceted quality implementing program (QIP) on the compliance of a “simplified 1-h bundle” (Sepsis 6) and hospital mortality of severe sepsis and septic shock patients out of the intensive care unit (ICU).MethodsEmergency departments (EDs) and medical wards (MWs) of 12 academic and non-academic hospitals in the Lombardy region (Northern Italy) were involved in a multi-faceted QIP, which included educational and organizational interventions. Patients with a clinical diagnosis of severe sepsis or septic shock according to the Sepsis-2 criteria were enrolled in two different periods: from May 2011 to November 2011 (before-QIP cohort) and from August 2012 to June 2013 (after-QIP cohort).Measurements and main resultsThe effect of QIP on bundle compliance and hospital mortality was evaluated in a before–after analysis. We enrolled 467 patients in the before-QIP group and 656 in the after-QIP group. At the time of enrollment, septic shock was diagnosed in 50% of patients, similarly between the two periods. In the after-QIP group, we observed increased compliance to the “simplified rapid (1 h) intervention bundle” (the Sepsis 6 bundle – S6) at three time-points evaluated (1 h, 13.7 to 18.7%, p = 0.018, 3 h, 37.1 to 48.0%, p = 0.013, overall study period, 46.2 to 57.9%, p < 0.001). We then analyzed compliance with S6 and hospital mortality in the before- and after-QIP periods, stratifying the two patients’ cohorts by admission characteristics. Adherence to the S6 bundle was increased in patients with severe sepsis in the absence of shock, in patients with serum lactate <4.0 mmol/L, and in patients with hypotension at the time of enrollment, regardless of the type of admission (from EDs or MWs). Subsequently, in an observational analysis, we also investigated the relation between bundle compliance and hospital mortality by logistic regression. In the after-QIP cohort, we observed a lower in-hospital mortality than that observed in the before-QIP cohort. This finding was reported in subgroups where a higher adherence to the S6 bundle in the after-QIP period was found. After adjustment for confounders, the QIP appeared to be independently associated with a significant improvement in hospital mortality. Among the single S6 procedures applied within the first hour of sepsis diagnosis, compliance with blood culture and antibiotic therapy appeared significantly associated with reduced in-hospital mortality.ConclusionA multi-faceted QIP aimed at promoting an early simplified bundle of care for the management of septic patients out of the ICU was associated with improved compliance with sepsis bundles and lower in-hospital mortality

    Expanding the potential of chiral chromatography for high-throughput screening of large compound libraries by means of sub-2μm Whelk-O 1 stationary phase in supercritical fluid conditions

    Get PDF
    With the aim of exploring the potential of ultra-fast chiral chromatography for high-throughput analysis, the new sub-2 micron Whelk-O 1 chiral stationary phase (CSP) has been employed in supercritical fluid conditions to screen 129 racemates, mainly of pharmaceutical interest. By using a 5-cm long column (0.46cm internal diameter), a single co-solvent (MeOH) and a 7-min gradient elution, 85% of acidic and neutral analytes considered in this work have been successfully resolved, with resolution (Rs) larger than 2 in more than 65% of cases. Moreover, almost a half of basic samples that, for their own characteristics, are known to be difficult to separate on Whelk-O 1 CSP, have shown Rs greater than 0.3. The screening of the entire library could be accomplished in less than 24h (single run) with 63% of positive score. For well-resolved enantiomers (Rs roughly included between 1 and 3), we show that method transfer from gradient to isocratic conditions is straightforward. In many cases, isocratic ultra-fast separations (with analysis time smaller than 60s) have been achieved by simply employing, as isocratic mobile phase, the eluent composition at which the second enantiomer was eluted in gradient mode. By considering the extension and variety of the library in terms of chemico-physical and structural properties of compounds and numerousness, we believe that this work demonstrates the real potential of the technique for high-throughput enantioselective screening

    Bronchus-associated lymphoid tissue lymphoma in a patient with primary Sj\uf6gren's syndrome

    No full text
    Despite its infrequent occurrence, the possible development of lymphoma or lymphoid lung disease in patients with Sj\uf6gren\u2019s syndrome should always be borne in mind. We describe a case of bronchus-associated lymphoid tissue (BALT) lymphoma in a patient with Sj\uf6gren\u2019s syndrome that clearly exemplifies the wide-ranging problems of diagnosing, treating and following such patients. This difficulty is due to the fact that the clinical and radiological findings suggest interstitial lung disease, and histological assays are required for a correct diagnosis. A precise knowledge of the various histological and radiological patterns of lung involvement can aid patient managemen

    The prognostic value of baseline 18F-FDG PET/CT in steroid-naïve large-vessel vasculitis : introduction of volume-based parameters

    No full text
    Purpose: The aim of this study was to analyse if the result of a baseline 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT scan, in large-vessel vasculitis (LVV) patients, is able to predict the course of the disease, not only in terms of presence/absence of final complications but also in terms of favourable/complicated progress (response to steroid therapy, time to steroid suspension, relapses, etc.). Methods: A total of 46 consecutive patients, who underwent 18F-FDG PET/CT between May 2010 and March 2013 for fever of unknown origin (FUO) or suspected vasculitis (before starting corticosteroid therapy), were enrolled. The diagnosis of LVV was confirmed in 17 patients. Considering follow-up results, positive LVV patients were divided into two groups, one characterized by favourable (nine) and the other by complicated progress (eight), on the basis of presence/absence of vascular complications, presence/absence of at least another positive PET/CT during follow-up and impossibility to comply with the tapering schedule of the steroid due to biochemical/symptomatic relapse. Vessel uptake in subjects of the two groups was compared in terms of intensity and extension. To evaluate the extent of active disease, we introduced two volume-based parameters: \u201cvolume of increased uptake\u201d (VIU) and \u201ctotal lesion glycolysis\u201d (TLG). The threshold used to calculate VIU on vessel walls was obtained by the \u201cvessel to liver\u201d ratio by means of receiver-operating characteristic analysis and was set at 0.92 7 liver maximum standardized uptake value in each patient. Results: Measures of tracer uptake intensity were significantly higher in patients with complicated progress compared to those with a favourable one (p < 0.05). Measures of disease extension were even more significant and TLG emerged as the best parameter to separate the two groups of patients (p = 0.01). Conclusion: This pilot study shows that, in LVV patients, the combined evaluation of the intensity and the extension of FDG vessel uptake at diagnosis can predict the clinical course of the disease, separating patients with favourable or complicated progress

    Expanding the potential of chiral chromatography for high-throughput screening of large compound libraries by means of sub-2μm Whelk-O 1 stationary phase in supercritical fluid conditions

    No full text
    With the aim of exploring the potential of ultra-fast chiral chromatography for high-throughput analysis, the new sub-2 micron Whelk-O 1 chiral stationary phase (CSP) has been employed in supercritical fluid conditions to screen 129 racemates, mainly of pharmaceutical interest.By using a 5-cm long column (0.46 cm internal diameter), a single co-solvent (MeOH) and a 7-min gradient elution, 85% of acidic and neutral analytes considered in this work have been successfully resolved, with resolution (R-s) larger than 2 in more than 65% of cases. Moreover, almost a half of basic samples that, for their own characteristics, are known to be difficult to separate on Whelk-O 1 CSP, have shown Rs greater than 0.3. The screening of the entire library could be accomplished in less than 24 h (single run) with 63% of positive score.For well-resolved enantiomers (R-s roughly included between 1 and 3), we show that method transfer from gradient to isocratic conditions is straightforward. In many cases, isocratic ultra-fast separations (with analysis time smaller than 60 s) have been achieved by simply employing, as isocratic mobile phase, the eluent composition at which the second enantiomer was eluted in gradient mode.By considering the extension and variety of the library in terms of chemico-physical and structural properties of compounds and numerousness, we believe that this work demonstrates the real potential of the technique for high-throughput enantioselective screening. (C) 2015 Elsevier B.V. All rights reserved

    Expanding the potential of chiral chromatography for high-throughput screening of large compound libraries by means of sub-2μm Whelk-O 1 stationary phase in supercritical fluid conditions

    No full text
    With the aim of exploring the potential of ultra-fast chiral chromatography for high-throughput analysis, the new sub-2 micron Whelk-O 1 chiral stationary phase (CSP) has been employed in supercritical fluid conditions to screen 129 racemates, mainly of pharmaceutical interest. By using a 5-cm long column (0.46cm internal diameter), a single co-solvent (MeOH) and a 7-min gradient elution, 85% of acidic and neutral analytes considered in this work have been successfully resolved, with resolution (Rs) larger than 2 in more than 65% of cases. Moreover, almost a half of basic samples that, for their own characteristics, are known to be difficult to separate on Whelk-O 1 CSP, have shown Rs greater than 0.3. The screening of the entire library could be accomplished in less than 24h (single run) with 63% of positive score. For well-resolved enantiomers (Rs roughly included between 1 and 3), we show that method transfer from gradient to isocratic conditions is straightforward. In many cases, isocratic ultra-fast separations (with analysis time smaller than 60s) have been achieved by simply employing, as isocratic mobile phase, the eluent composition at which the second enantiomer was eluted in gradient mode. By considering the extension and variety of the library in terms of chemico-physical and structural properties of compounds and numerousness, we believe that this work demonstrates the real potential of the technique for high-throughput enantioselective screening. © 2015 Elsevier B.V
    corecore