274 research outputs found

    A five-year survey for plastic surgery malpractice claims in Rome, Italy

    Get PDF
    (1) Introduction: Medical malpractice claims against both health institutions and physicians are a crucial topic in Italy, as well as in other countries, particularly regarding civil proceedings. Our study reports an analysis of all of the malpractice judgments concerning plastic surgery decided in the Civil Court of Rome between 2012 and 2016. (2) Methods: the database of the Observatory Project on Medical Responsibility (ORMe) was analyzed, which collects all of the judgments of the Civil Court of Rome, that is, the first instance district court. Therefore, neither the jurisprudence of the second level court nor that of the Supreme Court was taken into account. (3) Results: 144 judgments concerning plastic surgery were delivered in the five-year period of 2012–2016 (corresponding to 10.6% of total professional liability verdicts of the Civil Court of Rome in the same period). In 101/144 cases (70.14%), the claim was accepted. A total of €4,727,579.00 was paid in compensation for plastic surgery malpractice claims, with a range from a minimum amount of €1555.96 to a maximum amount of €1,425,155.00 and an average compensation of €46,807.71 per claim that was significantly lower compared to other surgical disciplines. (4) Conclusions: Our data confirm that the analyzed branch has a high litigation rate, with a prevalence of convictions for cosmetic procedures over reconstructive ones, both for malpractice and for violation of the informed consent. Plastic surgery is also confirmed among those branches in which the professionals are more frequently sued compared to health institutions

    A Novel Approach for an Integrated Straw tube-Microstrip Detector

    Full text link
    We report on a novel concept of silicon microstrips and straw tubes detector, where integration is accomplished by a straw module with straws not subjected to mechanical tension in a Rohacell ®^{\circledR} lattice and carbon fiber reinforced plastic shell. Results on mechanical and test beam performances are reported on as well.Comment: Accepted by Transactions on Nuclear Science (2005). 11 pages, 9 figures, uses lnfprep.st

    Understanding the Reactivity of a Thin Li1.5Al0.5Ge1.5(PO4)3 Solid-State Electrolyte toward Metallic Lithium Anode

    Get PDF
    The thickness of solid-state electrolytes (SSEs) significantly affects the energy density and safety performance of all-solid-state lithium batteries. However, a sufficient understanding of the reactivity toward lithium metal of ultrathin SSEs (<100 Âµm) based on NASICON remains lacking. Herein, for the first time, a self-standing and ultrathin (70 Âµm) NASICON-type Li1.5Al0.5Ge1.5(PO4)3 (LAGP) electrolyte via a scalable solution process is developed, and X-ray photoelectron spectroscopy reveals that changes in LAGP at the metastable Li–LAGP interface during battery operation is temperature dependent. Severe germanium reduction and decrease in LAGP particle size are detected at the Li–LAGP interface at elevated temperature. Oriented plating of lithium metal on its preferred (110) face occurs during in situ X-ray diffraction cycling

    Measurement results and improvements on an open EPR system

    Get PDF
    Electron spin resonance (ESR) is a spectroscopic method that allows to measure stable radicals induced by ionizing radiation. The EPR measurements can help to estimate the dose absorbed by people exposed during a nuclear disaster, detecting the number of radicals induced in their mobile phones due to the exposition [1]. Using conventional closed microwave cavities, the phone display must be fragmented in order to be introduced inside the resonator, becoming no more usable. The aim of this work is to develop a system, compatible with the spectrometer Bruker Elexys E500, able to preserve the sample integrity. The system uses an X-band resonant metallic cavity with a slit, realized on one side, for the leak of the excitation magnetic field and a Helmotz coil pair. The resonator allows measuring a sample lodged outside the cavity, while the coils produce a 100 kHz modulated field that encodes the output signal at a particular frequency and increases the SNR

    Micrometric Position Monitoring Using Fiber Bragg Grating Sensors in Silicon Detectors

    Full text link
    We show R&D results including long term stability, resolution, radiation hardness and characterization of Fiber Grating sensors used to monitor structure deformation, repositioning and surveying of silicon detector in High Energy Physics.Comment: Presented by S.Bianco at ICATPP05, Villa Olmo (Como) Italy, November 2005. 5 pages, 6 figures, uses lnfprep.st

    The Top-Implart Proton Linear Accelerator: Interim Characteristics of the 35 Mev Beam

    Get PDF
    In the framework of the Italian TOP-IMPLART project (Regione Lazio), ENEA-Frascati, ISS and IFO are developing and constructing the first proton linear accelerator based on an actively scanned beam for tumor radiotherapy with final energy of 150 MeV. An important feature of this accelerator is modularity: an exploitable beam can be delivered at any stage of its construction, which allows for immediate characterization and virtually continuous improvement of its performance. Currently, a sequence of 3 GHz accelerating modules combined with a commercial injector operating at 425 MHz delivers protons up to 35 MeV. Several dosimetry systems were used to obtain preliminary characteristics of the 35-MeV beam in terms of stability and homogeneity. Short-term stability and homogeneity better than 3% and 2.6%, respectively, were demonstrated; for stability an improvement with respect to the respective value obtained for the previous 27 MeV beam

    Handling the Background in IXPE Polarimetric Data

    Get PDF
    Imaging X-ray Polarimetry Explorer (IXPE) is a Small Explorer mission by NASA and Agenzia Spaziale Italiana, launched on 2021 December 9, dedicated to investigating X-ray polarimetry allowing angular-, time-, and energy-resolved observations in the 2-8 keV energy band. IXPE is in the science observation phase since 2022 January; it is comprised of three identical telescopes with grazing-incidence mirrors, each one having in the focal plane a gas pixel detector. In this paper, we present a possible guideline to obtain an optimal background selection in polarimetric analysis, and a rejection strategy to remove instrumental background. This work is based on the analysis of IXPE observations, aiming to improve as much as possible the polarimetric sensitivity. In particular, the developed strategies have been applied as a case study to the IXPE observation of the 4U 0142+61 magnetar

    Two- and Three-Dimensional Reconstruction and Analysis of the Straw Tubes Tomography in the Btev Experiment

    Full text link
    A check of the eccentricity of the aluminised kapton straw tubes used in the BTeV experiment is accomplished using X-ray tomography of the section of tubes modules. 2 and 3-dimensional images of the single tubes and of the modules are reconstructed and analysed. Preliminary results show that a precision better than 40 ÎĽ\mum can be reached on the measurement of the straw radii.Comment: Presented by F.Massa at ICATPP05, Villa Olmo (Como) Italy, November 2005. 4 pages, 8 figures, uses lnfprep.st

    CATANA protontherapy facility: The state of art of clinical and dosimetric experience

    Get PDF
    After nine years of activity, about 220 patients have been treated at the CATANA Eye Protontherapy facility. A 62MeV proton beam produced by a Superconducting Cyclotron is dedicated to radiotherapy of eye lesions, as uveal melanomas. Research and development work has been done to test different dosimetry devices to be used for reference and relative dosimetry, in order to achieve dose delivering accuracy. The follow-up results demonstrated the efficacy of proton beams and encouraged us in our activity in the fight against cancer
    • …
    corecore