279 research outputs found

    EXPERIMENTAL ANALYSIS OF A SCREEN-COVERED GROOVE HEAT PIPE

    Get PDF
    In this research, a heat pipe with screen-covered groove capillary structure was experimentally analyzed. The heat pipe was manufactured from a copper tube with the external diameter of 9.45mm, inner diameter of      6.20mm, and a total length of 200mm. A Wire Electrical Discharge Machining, or Wire-EDM, was used to manufacture axial microgrooves in the heat pipe. A layer of phosphor bronze mesh #100 completed the capillary structure. Distilled water was the working fluid and the loading filling ratio was 60% of the evaporator volume. The condenser was cooled by air forced convection, the adiabatic section was insulated with fiberglass, and the evaporator was heated by an electrical resistor and it was insulated from the environment with aeronautic insulation. The heat pipe was tested in horizontal position, under different heat loads varying from 5 up to 30W. The experimental results showed that the screen-covered groove worked satisfactorily as a capillary structure

    FLAT PLATE PULSATING HEAT PIPES WITH DIFFERENT CHANNEL GEOMETRIES FOR HIGH HEAT FLUX APPLICATIONS

    Get PDF
    The thermal performance of flat plate pulsating heat pipes with differentchannel geometries was performed in this experimental work. The testswere accomplished with two channel profiles, round and grooved. One ofthe channel geometries, located on the evaporator, can be considered novel,consisting of a round channel with two lateral grooves. Diffusion bondingtechnology was used to manufacture the PHPs made of two copper flatplates. Distilled water was used as the working fluid with a filling ratio of50% (17.9 ml) of the total volume. The pulsating heat pipes were tested atone position (vertical) under heat loads from 20 up to 2000 W. Theexperimental results showed that both flat plate pulsating heat pipesoperates successfully for high heat fluxes. The lateral grooves reduced thethermal resistance, being principally efficient in lower loads. Besides that,the novel channel considerably anticipated the operation startup. Therefore,a much better performance was obtained by the grooved channel PHP,which was constructed from a simple, low cost modification of thefabrication process

    Characterization of a Copper Powder for Heat Pipe Wick Applications

    Full text link
    In powder metallurgy, it is necessary to know the powder's nature to understand how the processing of a powder occurs. In this paper, a characterization of a copper powder for heat pipe wick applications was experimentally done. The copper powder manufacturing method was atomization. This metallic powder was characterized by Scanning Electron Microscopy (SEM), X-Ray Fluorescence Spectrometry (ED-XRF), and Laser Diffraction Granulometry. As a result, the purity and the shape are compatible with the powder manufacturing method and great for wicks. Also, the copper powder has a unimodal distribution that is excellent for capillary structures

    The ability of a limited metabolic assessment to identify pediatric stone formers with metabolic abnormalities

    Get PDF
    Introduction American Urological Association guidelines recommend a urinary metabolic evaluation after the first stone event in all pediatric stone patients. Prior studies identified hypercalciuria and urine hypovolemia as the most common abnormalities in children with urolithiasis. Recent data suggest that hypocitraturia is most prevalent. It was hypothesized that a limited evaluation would detect the majority of clinically significant metabolic abnormalities in pediatric stone formers. Material and methods A retrospective analysis of all children (<18 years of age) with renal/ureteral calculi evaluated at the study institution from 2005 to 2015 was performed. Children with ≥ one 24-h urinary metabolic profile after a clinical visit for renal/ureteral calculi were included. Those with bladder stones and those with undercollection or overcollection or missing urinary creatinine were excluded. Demographics and data from the first urinary metabolic profile and stone analyses were collected. The sensitivity, specificity, and positive and negative predictive value (NPV) of a limited urinary metabolic evaluation consisting of four parameters (24-h calcium, citrate, and oxalate and low urinary volume) were compared to a complete urinary metabolic profile. The number and type of metabolic abnormalities that would have been missed with this limited evaluation weredetermined. Results Of 410 patients, 21 were excluded for age ≥18 years, 13 for bladder stones, 248 for overcollections, 38 for undercollections, and 10 for missing creatinine. This left 80 patients for inclusion: median age 11.4 years, 60% female, and 96.3% white. Of the entire cohort, 69.6% had hypocitraturia, 52.5% had low urine volume, and 22.5% had hypercalciuria. Sensitivity was 87.5%. Specificity could not be calculated because no patients had a normal complete metabolic evaluation. The NPV was zero, and the positive predictive value was 100%, but these are artifacts resulting from the absence of patients with a normal complete metabolic evaluation. Of the 80 patients, 10 had at least one abnormality missed by a limited metabolic evaluation (Table 1). The missed abnormalities were high pH (n = 6), abnormal 24-h phosphorus (low in 1 patient and high in 1 patient), low 24-h magnesium (n = 3), low 24-h potassium (n = 3), and high 24-h sodium (n = 4). Discussion A limited urinary metabolic evaluation would have detected the vast majority of clinically significant metabolic abnormalities in the study sample. Approximately two-thirds of the study patients submitted inadequate 24-h urine specimens. Conclusions A simplified approach to metabolic evaluation in first-time stone formers with a stone analysis available was proposed. This streamlined approach could simplify the metabolic evaluation and reduce health care costs

    Thermal Analysis of a Finned Thermosyphon for Heat Exchanger Applications

    Full text link
    A thermosyphon is a gravity-assisted heat pipe used to improve the heat transfer in several applications. In this paper, a thermal analysis of a finned thermosyphon for heat exchanger applications was experimentally researched. The thermosyphon was manufactured from a copper tube the external diameter of 9.45 mm, the inner diameter of 7.75 mm, and a total length of 200 mm. The working fluid used was water with a filling ratio of 40% of the evaporator volume. The condenser was cooled by air forced convection, the adiabatic section was insulated with fiberglass and the evaporator was heated by an electrical resistor. Experimental tests were performed to a heat load from 5 up to 50W at vertical position (evaporator above condenser). As a result of the research, the thermosyphon operated satisfactorily to the tested position. Also, the finned thermosyphon obtained better thermal performance than the un-finned condenser, proving the effectiveness of the fin application

    Initial collection of an inadequate 24-hour urine sample in children does not predict subsequent inadequate collections

    Get PDF
    Introduction Approximately half of adult stone formers submit specimens that are either under or over collections as determined by 24-h creatinine/kg. Previously identified predictors of inadequate collection in adults include female sex, older age, higher body mass index (BMI), vitamin D supplementation, and weekday collection. Objective The objective of this study is to determine risk factors for inadequate 24-h urinary specimen collection in the pediatric population. Study design A retrospective analysis of all children (<18 years of age) with renal and/or ureteral calculi evaluated at the study tertiary care pediatric center from 2005 to 2015 was performed. Those who had at least one 24-h urinary metabolic profile after a clinical visit for kidney and/or ureteral stones were included; children with bladder stones were excluded. Adequate collections had a urine creatinine of 10–15 mg/kg/24 h. A bivariate analysis of potential factors associated with inadequate collection of the initial urinary metabolic profile, including child demographics, parental socio-economic factors, history of stone surgery, and weekday vs. weekend urine collection, was performed. A mixed-effects logistic regression, controlling for correlation of specimens from the same patient, was also performed to determine whether an initial inadequate collection predicted a subsequent inadequate collection. Results Of 367 patients, 80 had an adequate collection (21.9%): median age, 13 years (interquartile range, 8–16); 61.1% female; 93.5% white; 19.5% obese; and 13.0% overweight. No parental or child factors were associated with inadequate collection (Summary Table). Of inadequate collections, more than 80% were over collections. In the 175 patients with more than one 24-h urinary specimen collection, the effect of an initial inadequate collection on subsequent inadequate collections was not significant after controlling for the correlation of samples from the same patient (p = 0.8). Discussion Any parental or child factors associated with the collection of inadequate 24-h urine specimens in children were not found. An initial inadequate collection does not predict subsequent inadequate collections. It was surprising that >80% of the inadequate collections were over collections rather than under collections. Possible explanations are that children collected urine samples for longer than the 24-h period or that stone-forming children produce more creatinine per 24-h period than healthy children due to hyperfiltration. Conclusion Inadequate collections are very common, and the risk factors for them are unclear. A repeat collection would be suggested if the first is inadequate. Further studies must be planned to explore barriers to accurate specimen collection using qualitative research methodology

    Comparison of cost-effectiveness and postoperative outcomes following integration of a stiff shaft glidewire into percutaneous nephrolithotripsy

    Get PDF
    Aims: To analyze the cost effectiveness of integrating a stiff shaft glidewire (SSGW) in percutaneous nephrolithotripsy (PCNL) relative to standard technique (ST). This is prudent because healthcare providers are experiencing increased pressure to improve procedure-related cost containment. Methods: ST for PCNL at our institution involves a hydrophilic glidewire during initial percutaneous access and then two new stiff shaft wires. The SSGW is a hydrophilic wire used for initial access and the remainder of the procedure. We collected operating room (OR) costs for all primary, unilateral PCNL cases over a 5-month period during which ST for PCNL was used at a single institution with a single surgeon and compared with a 6-month period during which a SSGW was used. Mean costs for each period were then compared along with stone-free rates and complications. Results: We included 17 total cases in the ST group and 22 in the SSGW group. The average operating room supply cost for the ST group was 1937.32and1937.32 and 1559.39 in the SSGW group. The net difference of $377.93 represents a nearly 20% decrease in cost. This difference was statistically significant (p = 0.031). There was no difference in postoperative stone-free rates (82.4% versus 86.4%, p = 1.0, respectively) or complications (23.5% versus 13.6%, p = 0.677, respectively) between ST and SSGW groups. Conclusion: Transitioning to a SSGW has reduced OR supply cost by reducing the number of supplies required. The change in wire did not affect stone-free rates or complications

    Centralized Modularity of N-Linked Glycosylation Pathways in Mammalian Cells

    Get PDF
    Glycosylation is a highly complex process to produce a diverse repertoire of cellular glycans that are attached to proteins and lipids. Glycans are involved in fundamental biological processes, including protein folding and clearance, cell proliferation and apoptosis, development, immune responses, and pathogenesis. One of the major types of glycans, N-linked glycans, is formed by sequential attachments of monosaccharides to proteins by a limited number of enzymes. Many of these enzymes can accept multiple N-linked glycans as substrates, thereby generating a large number of glycan intermediates and their intermingled pathways. Motivated by the quantitative methods developed in complex network research, we investigated the large-scale organization of such N-linked glycosylation pathways in mammalian cells. The N-linked glycosylation pathways are extremely modular, and are composed of cohesive topological modules that directly branch from a common upstream pathway of glycan synthesis. This unique structural property allows the glycan production between modules to be controlled by the upstream region. Although the enzymes act on multiple glycan substrates, indicating cross-talk between modules, the impact of the cross-talk on the module-specific enhancement of glycan synthesis may be confined within a moderate range by transcription-level control. The findings of the present study provide experimentally-testable predictions for glycosylation processes, and may be applicable to therapeutic glycoprotein engineering

    Electromagnetic Guided Percutaneous Renal Access Outcomes Among Surgeons and Trainees of Different Experience Levels: A Pilot Study

    Get PDF
    Objective To determine feasibility of an electromagnetic (EM) guidance system (Auris Health, Redwood City, CA) in obtaining percutaneous renal access among urologists and trainees of different experience levels. EM-guidance is appealing for access as it allows real time, 3-dimensional targeting without radiation. Few studies have explored this for percutaneous nephrolithotomy (PCNL) and none have assessed its potential to decrease the learning curve in obtaining access using traditional techniques. Methods Institutional Animal Care and Use Committee approval was obtained to compare EM-guided percutaneous access to fluoroscopic guided access in a porcine model. Voluntary participants included urology trainees and faculty. They were categorized as beginner (no prior primary percutaneous nephrolithotomyexperience), intermediate (10-100 prior) and advanced (>100). Each participant attempted an EM and fluoroscopic guided puncture. Primary outcome was successful puncture. Secondary outcomes included access time, fluoroscopy time, and number of attempts. Participants were limited to 3 attempts and 10 minutes total to obtain access using each technique. Results Fourteen participants (6 beginners, 4 intermediates, and 4 experts) attempted 28 punctures. Overall success using EM-guidance was 93% compared to 71% using fluoroscopy ( P = .33). EM punctures had shorter access times (85 vs 255 seconds, P <.01) required fewer attempts (1 vs 2, P = .04) and had decreased associated fluoroscopy times (1 vs 96 seconds, P <.01) excluding the initial retrograde pyelogram and guidance of the ureteroscope to the desired calyx. Beginners showed comparable success rates and outcomes relative to experts despite higher access times. Conclusion EM-guidance is a promising new technique to decrease the learning curve of percutaneous access with high success rates and minimal radiation
    corecore